Partial discharge detection in transformer winding using FRA analysis

被引:0
|
作者
Aissaoui, Nassima [1 ]
Houassine, Hamza [1 ,2 ]
Kabache, Nadir [1 ,2 ]
机构
[1] Univ Medea, Medea, Algeria
[2] Univ Bouira, Res Lab Elect Engn & Automat, Bouira, Algeria
来源
PRZEGLAD ELEKTROTECHNICZNY | 2022年 / 98卷 / 08期
关键词
transformer winding; partial discharge (PD); Particule swarm optimization (PSO); Frequency response analysis (FRA); POWER TRANSFORMERS;
D O I
10.15199/48.2022.08.10
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In power transformer, Partial Discharge is a cause of insulation failure, and thus, procedures for the area of PD sources are required. In this paper, an endeavor has been made to present frequency response analysis (FRA) for the discovery of PD by identifying the parameters of the winding by the particule swarm optimization (PSO), and giving its impedance according to the frequency. Comparison between the frequency responses of healthy winding and the affected one the is made to detect the failure associate to the partial discharge.
引用
收藏
页码:52 / 56
页数:5
相关论文
共 50 条
  • [21] Improved Power Transformer Winding Fault Detection using FRA Diagnostics - Part 1: Axial Displacement Simulation
    Hashemnia, Naser
    Abu-Siada, A.
    Islam, S.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (01) : 556 - 563
  • [22] Distortion caused by partial discharge propagation along power transformer winding
    Gao, Wen-Sheng
    Gui, Jun-Feng
    Tan, Ke-Xiong
    Jiao, Cui-Ping
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2002, 22 (04): : 31 - 36
  • [23] Preliminary Investigations on Propagation of Partial Discharge Induced Currents in a Transformer Winding
    Raman, Santosh Janaki
    Kumar, Udaya
    2017 3RD INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (CATCON), 2017, : 293 - 297
  • [24] MULTIPLE PARTIAL DISCHARGE SOURCE DISCRIMINATION IN A HIGH VOLTAGE TRANSFORMER WINDING
    Ali, N. H. Nik
    Rapisarda, P.
    Lewin, P. L.
    2017 INSUCON - 13TH INTERNATIONAL ELECTRICAL INSULATION CONFERENCE (INSUCON), 2017,
  • [25] An Improved Method for Identification of Mechanical Damage in an Isolated Transformer Winding Using FRA
    Rao, Tirlingi Madhava
    Mitra, Sourav
    Pramanik, Saurav
    2022 IEEE 6TH INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS, CATCON, 2022, : 268 - 272
  • [26] An Electromagnetic Time Reversal Technique to Locate Partial Discharge in Transformer Winding
    Rathod, Viral B.
    Kumbhar, Ganesh B.
    Bhalja, Bhavesh R.
    IEEE LETTERS ON ELECTROMAGNETIC COMPATIBILITY PRACTICE AND APPLICATIONS, 2023, 5 (04): : 149 - 153
  • [27] Improved detection of power transformer winding movement by extending the FRA high frequency range
    Wang, M
    Vandermaar, AJ
    Srivastava, KD
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (03) : 1930 - 1938
  • [28] Detection of Power Transformer Winding Deformation Using Improved FRA Based on Binary Morphology and Extreme Point Variation
    Zhao, Zhongyong
    Yao, Chenguo
    Li, Chengxiang
    Islam, Syed
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (04) : 3509 - 3519
  • [29] y The actual measurement and analysis of transformer winding deformation fault degrees by FRA using mathematical indicators
    Ni Jianqiang
    Zhao Zhongyong
    Tan Shan
    Chen Yu
    Yao Chenguo
    Tang Chao
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 184
  • [30] Improved Power Transformer Winding Fault Detection using FRA Diagnostics - Part 2: Radial Deformation Simulation
    Hashemnia, Naser
    Abu-Siada, A.
    Islam, S.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (01) : 564 - 570