The effect of adding a new monomer "Phene" on the polymerization shrinkage reduction of a dental resin composite

被引:48
|
作者
He, Jingwei [1 ,2 ,3 ]
Garoushi, Sufyan [1 ,2 ]
Sailynoja, Eija [4 ]
Vallittu, Palm K. [1 ,2 ,5 ]
Lassila, Lippo [1 ,2 ]
机构
[1] Univ Turku, Dept Biomat Sci, Inst Dent, Itainen Pitkakatu 4 B, FI-20520 Turku, Finland
[2] Univ Turku, TCBC, Inst Dent, Turku, Finland
[3] South China Univ Technol, Coll Mat Sci & Engn, Guangzhou, Guangdong, Peoples R China
[4] Stick Tech Ltd, Res Dev & Prod Dept, GC Grp, Turku, Finland
[5] City Turku Welf Div, Oral Hlth Care, Turku, Finland
关键词
Shrinkage stress; Physical properties; Volumetric; Shrinkage; Degree of conversiona; MECHANICAL-PROPERTIES; STRESS; ANTIBACTERIAL; PERFORMANCE; CONVERSION; WEAR;
D O I
10.1016/j.dental.2019.02.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. A new photocurable monomer, "Phene" (N-methyl-bis(ethyl-carbamate-isoproply-alpha-methylstyryl)amine) was synthesized and incorporated into Bis-GMA/TEGDMA with the aim of reducing polymerization shrinkage swithout detriment to the physical properties and wearing of the resin composites. Methods. Phene was synthesized through a 2-step reaction route, and its structure was confirmed by FT-IR and H-1-NMR spectra. Phene was incorporated into Bis-GMA/TEGDMA (50/50, wt/wt) with a series of mass fraction (from 0 wt% to 40 wt%). Experimental resin composites were prepared by mixing 29 wt% of resin matrix to 71 wt% of particulate-fillers. Degree of conversion (DC) was determined by FT-IR analysis. The volumetric shrinkage (VS) was calculated as a buoyancy change in distilled water by means of the Archimedes principle. Polymerization shrinkage-stress (SS) was measured using the tensilometer technique. The flexural strength (FS), modulus (FM), and fracture toughness (FT) were measured using a three-point bending setup. A wear test was conducted with 15000 cycles using a dual-axis chewing simulator. Wear depth was measured by a three-dimensional (3D) non-contact optical-profilometer. Results. ANOVA analysis showed that when mass fraction of Phene in resin matrix was more than 10 wt%, the obtained resin composite formulation had lower DC, VS and SS than control resin composite (p < 0.05). In general, the experimental resin composites had comparable FS and FM (p > 0.05) when the mass fraction of Phene in resin matrix was not more than 20 wt %. Resin composite with 20 wt% Phene had the lowest wear depth and fracture toughness values. Significance. The overall tested properties prove that including Phene up to 20 wt% into Bis-GMA/TEGDMA resin could be potentially useful in the formulation of low-shrinkage resin composites. (C) 2019 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:627 / 635
页数:9
相关论文
共 50 条
  • [41] The behavior of adhesive layer under composite resin polymerization shrinkage.
    Francci, C
    Nishimura, RL
    Mariya, RA
    Mano, ES
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 275 - 275
  • [42] Influence of photoactivation technique in shrinkage and microhardness of dental composite resin.
    Barreiros, ID
    Moreira, M
    Gonçalves, PJ
    Souza, EL
    Giovannini, JFBG
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 275 - 275
  • [43] Process Parameter Optimization for Minimum Polymerization Shrinkage of Resin Based Dental Material
    Pratap, Bhanu
    Gupta, R. K.
    Ghosh, S. S.
    Bhardwaj, Bhuvnesh
    1ST INTERNATIONAL CONFERENCE ON ADVANCES IN MECHANICAL ENGINEERING AND NANOTECHNOLOGY (ICAMEN 2019), 2019, 2148
  • [44] Contraction (shrinkage) in polymerization. Part II. Dental resin composites
    Linden, L.-A.
    Jakubiak, J.
    Polimery/Polymers, 2001, 46 (09): : 590 - 595
  • [45] The effect of high-irradiance rapid polymerization on degree of conversion, monomer elution, polymerization shrinkage and porosity of bulk-fill resin composites
    Lempel, Edina
    Szebeni, Donat
    Ori, Zsuzsanna
    Kiss, Tamas
    Szalma, Jozsef
    Lovasz, Balint Viktor
    Kunsagi-Mate, Sandor
    Boddi, Katalin
    DENTAL MATERIALS, 2023, 39 (04) : 442 - 453
  • [46] Development of low-shrinkage dental adhesives via blending with spiroorthocarbonate expanding monomer and unsaturated epoxy resin monomer
    Wang, Zonghua
    Zhang, Xiaoran
    Yao, Shuo
    Zhao, Jiaxin
    Zhou, Chuanjian
    Wu, Junling
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 133
  • [47] Polymerization shrinkage evaluation in experimental dental composite filled with montmorillonite nanoparticles
    Luiza M. P. Campos
    Letícia C. Boaro
    Tamiris M. R. Santos
    Vinícius J. Santos
    Rebeca Grecco-Romano
    Mariana J. Santos
    Duclerc F. Parra
    Journal of Thermal Analysis and Calorimetry, 2018, 131 : 771 - 774
  • [48] Polymerization shrinkage evaluation in experimental dental composite filled with montmorillonite nanoparticles
    Campos, Luiza M. P.
    Boaro, Leticia C.
    Santos, Tamiris M. R.
    Santos, Vinicius J.
    Grecco-Romano, Rebeca
    Santos, Mariana J.
    Parra, Duclerc F.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2018, 131 (01) : 771 - 774
  • [49] Measuring polymerization shrinkage of dental composite by using PhS-OCT
    Ni, Zihao
    Xie, Shengli
    Liao, Wenjian
    Bai, Yulei
    Dong, Bo
    MEASUREMENT, 2023, 221
  • [50] Polymerization Shrinkage and Stress of Silorane-based Dental Restorative Composite
    Lee, In-Bog
    Park, Sung-Hwan
    Kweon, Hyun-Jeong
    Gu, Ja-Uk
    Choi, Nak-Sam
    COMPOSITES RESEARCH, 2013, 26 (03): : 182 - 188