The effect of adding a new monomer "Phene" on the polymerization shrinkage reduction of a dental resin composite

被引:48
|
作者
He, Jingwei [1 ,2 ,3 ]
Garoushi, Sufyan [1 ,2 ]
Sailynoja, Eija [4 ]
Vallittu, Palm K. [1 ,2 ,5 ]
Lassila, Lippo [1 ,2 ]
机构
[1] Univ Turku, Dept Biomat Sci, Inst Dent, Itainen Pitkakatu 4 B, FI-20520 Turku, Finland
[2] Univ Turku, TCBC, Inst Dent, Turku, Finland
[3] South China Univ Technol, Coll Mat Sci & Engn, Guangzhou, Guangdong, Peoples R China
[4] Stick Tech Ltd, Res Dev & Prod Dept, GC Grp, Turku, Finland
[5] City Turku Welf Div, Oral Hlth Care, Turku, Finland
关键词
Shrinkage stress; Physical properties; Volumetric; Shrinkage; Degree of conversiona; MECHANICAL-PROPERTIES; STRESS; ANTIBACTERIAL; PERFORMANCE; CONVERSION; WEAR;
D O I
10.1016/j.dental.2019.02.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. A new photocurable monomer, "Phene" (N-methyl-bis(ethyl-carbamate-isoproply-alpha-methylstyryl)amine) was synthesized and incorporated into Bis-GMA/TEGDMA with the aim of reducing polymerization shrinkage swithout detriment to the physical properties and wearing of the resin composites. Methods. Phene was synthesized through a 2-step reaction route, and its structure was confirmed by FT-IR and H-1-NMR spectra. Phene was incorporated into Bis-GMA/TEGDMA (50/50, wt/wt) with a series of mass fraction (from 0 wt% to 40 wt%). Experimental resin composites were prepared by mixing 29 wt% of resin matrix to 71 wt% of particulate-fillers. Degree of conversion (DC) was determined by FT-IR analysis. The volumetric shrinkage (VS) was calculated as a buoyancy change in distilled water by means of the Archimedes principle. Polymerization shrinkage-stress (SS) was measured using the tensilometer technique. The flexural strength (FS), modulus (FM), and fracture toughness (FT) were measured using a three-point bending setup. A wear test was conducted with 15000 cycles using a dual-axis chewing simulator. Wear depth was measured by a three-dimensional (3D) non-contact optical-profilometer. Results. ANOVA analysis showed that when mass fraction of Phene in resin matrix was more than 10 wt%, the obtained resin composite formulation had lower DC, VS and SS than control resin composite (p < 0.05). In general, the experimental resin composites had comparable FS and FM (p > 0.05) when the mass fraction of Phene in resin matrix was not more than 20 wt %. Resin composite with 20 wt% Phene had the lowest wear depth and fracture toughness values. Significance. The overall tested properties prove that including Phene up to 20 wt% into Bis-GMA/TEGDMA resin could be potentially useful in the formulation of low-shrinkage resin composites. (C) 2019 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:627 / 635
页数:9
相关论文
共 50 条
  • [31] Bonding Performance of a New Resin Core System with a Low-Polymerization-Shrinkage Monomer to Root Canal Dentin
    Hatayama, Takashi
    Tabata, Tomoko
    Kibe, Kota
    Ikeda, Masaomi
    Sumi, Yasunori
    Shimada, Yasushi
    POLYMERS, 2024, 16 (23)
  • [32] Contraction (shrinkage) in polymerization -: Part II.: Dental resin composites
    Lindén, LA
    Jakubiak, J
    POLIMERY, 2001, 46 (09) : 590 - 595
  • [33] Effect of monomer type and 4-META on polymerization of molybdenum-resin composite.
    Miyagawa, Y
    Wanichacheva, N
    Petsom, A
    Ogura, H
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A85 - A85
  • [34] Effect of power density on shrinkage of dental resin materials
    Oberholzer, TG
    Pameijer, CH
    Grobler, SR
    Rossouw, RJ
    OPERATIVE DENTISTRY, 2003, 28 (05) : 622 - 627
  • [35] Effect of initiation site on direction of polymerization shrinkage of light-curving composite resin.
    Bae, JH
    Um, CM
    Kwon, HC
    Cho, BH
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 449 - 449
  • [36] Effect of stepped light exposure on the volumetric polymerization shrinkage and bulk modulus of dental composites and an unfilled resin
    Price, RB
    Rizkalla, AS
    Hall, GC
    AMERICAN JOURNAL OF DENTISTRY, 2000, 13 (04): : 176 - 180
  • [37] Control of polymerization shrinkage and stress in nanogel-modified monomer and composite materials
    Moraes, Rafael R.
    Garcia, Jeffrey W.
    Barros, Matthew D.
    Lewis, Steven H.
    Pfeifer, Carmem S.
    Liu, JianCheng
    Stansbury, Jeffrey W.
    DENTAL MATERIALS, 2011, 27 (06) : 509 - 519
  • [38] Characterization of a Low Shrinkage Dental Composite Containing Bismethylene Spiroorthocarbonate Expanding Monomer
    Fu, Jing
    Liu, Wenjia
    Hao, Zhichao
    Wu, Xiangnan
    Yin, Jian
    Panjiyar, Anil
    Liu, Xiaoqing
    Shen, Jiefei
    Wang, Hang
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2014, 15 (02): : 2400 - 2412
  • [39] Augmentation of composite resin to reduce polymerization shrinkage and improve handling.
    Ritsco, RG
    Chan, DCN
    Rawls, HR
    Lyles, MB
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 2243 - 2243
  • [40] Effect of PRIMM on polymerization shrinkage of composite.
    Craigo, RA
    Suh, BI
    Rowley, L
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 170 - 170