Comparison of digital mammography and digital breast tomosynthesis in the detection of architectural distortion

被引:55
|
作者
Dibble, Elizabeth H. [1 ]
Lourenco, Ana P. [1 ]
Baird, Grayson L. [1 ,2 ]
Ward, Robert C. [1 ]
Maynard, A. Stanley [1 ]
Mainiero, Martha B. [1 ]
机构
[1] Brown Univ, Rhode Isl Hosp, Warren Alpert Med Sch, Dept Diagnost Imaging, Providence, RI 02903 USA
[2] Rhode Isl Hosp, Lifespan Biostat Core, 593 Eddy St, Providence, RI 02903 USA
关键词
Mammography; Breast; Early diagnosis; Digital breast tomosynthesis; Architectural distortion; SCREENING MAMMOGRAPHY; CLINICAL-EXPERIENCE; OCCULT; IMPLEMENTATION; PERFORMANCE; POPULATION; FEATURES; CANCERS; RECALL;
D O I
10.1007/s00330-017-4968-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare interobserver variability (IOV), reader confidence, and sensitivity/specificity in detecting architectural distortion (AD) on digital mammography (DM) versus digital breast tomosynthesis (DBT). This IRB-approved, HIPAA-compliant reader study used a counterbalanced experimental design. We searched radiology reports for AD on screening mammograms from 5 March 2012-27 November 2013. Cases were consensus-reviewed. Controls were selected from demographically matched non-AD examinations. Two radiologists and two fellows blinded to outcomes independently reviewed images from two patient groups in two sessions. Readers recorded presence/absence of AD and confidence level. Agreement and differences in confidence and sensitivity/specificity between DBT versus DM and attendings versus fellows were examined using weighted Kappa and generalised mixed modeling, respectively. There were 59 AD patients and 59 controls for 1,888 observations (59 x 2 (cases and controls) x 2 breasts x 2 imaging techniques x 4 readers). For all readers, agreement improved with DBT versus DM (0.61 vs. 0.37). Confidence was higher with DBT, p = .001. DBT achieved higher sensitivity (.59 vs. .32), p < .001; specificity remained high (>.90). DBT achieved higher positive likelihood ratio values, smaller negative likelihood ratio values, and larger ROC values. DBT decreases IOV, increases confidence, and improves sensitivity while maintaining high specificity in detecting AD. aEuro cent Digital breast tomosynthesis decreases interobserver variability in the detection of architectural distortion. aEuro cent Digital breast tomosynthesis increases reader confidence in the detection of architectural distortion. aEuro cent Digital breast tomosynthesis improves sensitivity in the detection of architectural distortion.
引用
收藏
页码:3 / 10
页数:8
相关论文
共 50 条
  • [41] Diagnosis of architectural distortion on digital breast tomosynthesis using radiomics and deep learning
    Chen, Xiao
    Zhang, Yang
    Zhou, Jiahuan
    Wang, Xiao
    Liu, Xinmiao
    Nie, Ke
    Lin, Xiaomin
    He, Wenwen
    Su, Min-Ying
    Cao, Guoquan
    Wang, Meihao
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [42] Editorial Comment: Architectural Distortion on Digital Breast Tomosynthesis-to Excise or Not to Excise?
    Lee, Amie Y.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 219 (01) : 54 - 54
  • [43] Editorial Comment: Appropriate Management of Architectural Distortion Detected on Digital Breast Tomosynthesis
    Durand, Melissa A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2021, 217 (04) : 854 - 854
  • [44] Architectural Distortion on Screening Digital Breast Tomosynthesis: Pathologic Outcomes and Indicators of Malignancy
    Wadhwa, Anubha
    Majidi, Shadie S.
    Cherian, Solomon
    Dykstra, Daniel S.
    Deitch, Sarah G.
    Hansen, Colin
    Bhave, Sampada
    Koch, Kevin M.
    JOURNAL OF BREAST IMAGING, 2021, 3 (01) : 34 - 43
  • [45] Architectural distortion detection in digital breast tomosynthesis with adaptive receptive field and adaptive convolution kernel shape
    Li, Yue
    He, Zilong
    Ma, Xiangyuan
    Xu, Weimin
    Wen, Chanjuan
    Zeng, Hui
    Zeng, Weixiong
    Wu, Zeqi
    Qin, Genggeng
    Chen, Weiguo
    Lu, Yao
    MEDICAL IMAGING 2021: COMPUTER-AIDED DIAGNOSIS, 2021, 11597
  • [46] Assessment of the uterine dose in digital mammography and digital breast tomosynthesis
    Cepeda Martins, A. R.
    Di Maria, S.
    Afonso, J.
    Pereira, M.
    Pereira, J.
    Vaz, P.
    RADIOGRAPHY, 2022, 28 (02) : 333 - 339
  • [47] Pipeline for effective denoising of digital mammography and digital breast tomosynthesis
    Borges, Lucas R.
    Bakic, Predrag R.
    Foi, Alessandro
    Maidment, Andrew D. A.
    Vieira, Marcelo A. C.
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [48] A new breast phantom suitable for digital mammography, contrast-enhanced digital mammography and digital breast tomosynthesis
    Zhang, Changsheng
    Fu, Jian
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (04):
  • [49] A comparison of the accuracy of film-screen mammography, full-field digital mammography, and digital breast tomosynthesis
    Michell, M. J.
    Iqbal, A.
    Wasan, R. K.
    Evans, D. R.
    Peacock, C.
    Lawinski, C. P.
    Douiri, A.
    Wilson, R.
    Whelehan, P.
    CLINICAL RADIOLOGY, 2012, 67 (10) : 976 - 981
  • [50] Comparison of Digital Breast Tomosynthesis and Two-dimensional Mammography Response
    Sharpe, Richard E., Jr.
    Mehta, Tejas
    Venkataraman, Shambhavi
    RADIOLOGY, 2016, 280 (03) : 981 - 981