Comparison of digital mammography and digital breast tomosynthesis in the detection of architectural distortion

被引:55
|
作者
Dibble, Elizabeth H. [1 ]
Lourenco, Ana P. [1 ]
Baird, Grayson L. [1 ,2 ]
Ward, Robert C. [1 ]
Maynard, A. Stanley [1 ]
Mainiero, Martha B. [1 ]
机构
[1] Brown Univ, Rhode Isl Hosp, Warren Alpert Med Sch, Dept Diagnost Imaging, Providence, RI 02903 USA
[2] Rhode Isl Hosp, Lifespan Biostat Core, 593 Eddy St, Providence, RI 02903 USA
关键词
Mammography; Breast; Early diagnosis; Digital breast tomosynthesis; Architectural distortion; SCREENING MAMMOGRAPHY; CLINICAL-EXPERIENCE; OCCULT; IMPLEMENTATION; PERFORMANCE; POPULATION; FEATURES; CANCERS; RECALL;
D O I
10.1007/s00330-017-4968-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare interobserver variability (IOV), reader confidence, and sensitivity/specificity in detecting architectural distortion (AD) on digital mammography (DM) versus digital breast tomosynthesis (DBT). This IRB-approved, HIPAA-compliant reader study used a counterbalanced experimental design. We searched radiology reports for AD on screening mammograms from 5 March 2012-27 November 2013. Cases were consensus-reviewed. Controls were selected from demographically matched non-AD examinations. Two radiologists and two fellows blinded to outcomes independently reviewed images from two patient groups in two sessions. Readers recorded presence/absence of AD and confidence level. Agreement and differences in confidence and sensitivity/specificity between DBT versus DM and attendings versus fellows were examined using weighted Kappa and generalised mixed modeling, respectively. There were 59 AD patients and 59 controls for 1,888 observations (59 x 2 (cases and controls) x 2 breasts x 2 imaging techniques x 4 readers). For all readers, agreement improved with DBT versus DM (0.61 vs. 0.37). Confidence was higher with DBT, p = .001. DBT achieved higher sensitivity (.59 vs. .32), p < .001; specificity remained high (>.90). DBT achieved higher positive likelihood ratio values, smaller negative likelihood ratio values, and larger ROC values. DBT decreases IOV, increases confidence, and improves sensitivity while maintaining high specificity in detecting AD. aEuro cent Digital breast tomosynthesis decreases interobserver variability in the detection of architectural distortion. aEuro cent Digital breast tomosynthesis increases reader confidence in the detection of architectural distortion. aEuro cent Digital breast tomosynthesis improves sensitivity in the detection of architectural distortion.
引用
收藏
页码:3 / 10
页数:8
相关论文
共 50 条
  • [31] Comparison of Digital Breast Tomosynthesis and Two-dimensional Mammography
    Korporaal, Johannes G.
    Mertelmeier, Thomas
    RADIOLOGY, 2016, 280 (03) : 980 - 981
  • [32] Breast Cancers Detected during a Decade of Screening with Digital Breast Tomosynthesis: Comparison with Digital Mammography
    Philpotts, Liane Elizabeth
    Grewal, Jaskirandeep Kaur
    Horvath, Laura Jean
    Giwerc, Michelle Young
    Staib, Lawrence
    Etesami, Maryam
    RADIOLOGY, 2024, 312 (03)
  • [33] Breast MRI, digital mammography and breast tomosynthesis: Comparison of three methods for early detection of breast cancer
    Roganovic, Dragana
    Djilas, Dragana
    Vujnovic, Sasa
    Pavic, Dag
    Stojanov, Dragan
    BOSNIAN JOURNAL OF BASIC MEDICAL SCIENCES, 2015, 15 (04) : 64 - 68
  • [34] Digital breast tomosynthesis: a comparison of the accuracy of digital breast tomosynthesis, two-dimensional digital mammography and two-dimensional screening mammography (film-screen)
    MJ Michell
    RK Wasan
    P Whelehan
    A Iqbal
    CP Lawinski
    AN Donaldson
    DR Evans
    C Peacock
    ARM Wilson
    Breast Cancer Research, 11 (Suppl 2)
  • [35] Digital breast tomosynthesis: a comparison of the accuracy of digital breast tomosynthesis, two-dimensional digital mammography and two-dimensional screening mammography (film-screen)
    Michell, M. J.
    Wasan, R. K.
    Whelehan, P.
    Iqbal, A.
    Lawinski, C. P.
    Donaldson, A. N.
    Evans, D. R.
    Peacock, C.
    Wilson, A. R. M.
    BREAST CANCER RESEARCH, 2009, 11
  • [36] Comparison of Call-Back Rates between Digital Mammography and Digital Breast Tomosynthesis
    Scott, Anthony M.
    Lashley, Madison G.
    Drury, Nicholas B.
    Dale, Paul S.
    AMERICAN SURGEON, 2019, 85 (08) : 855 - 857
  • [37] A comparison of reading times in full-field digital mammography and digital breast tomosynthesis
    Connor, S. J.
    Lim, Y. Y.
    Tate, C.
    Entwistle, H.
    Morris, J.
    Whiteside, S.
    Sergeant, J.
    Wilson, M.
    Beetles, U.
    Boggis, C.
    Gilbert, F.
    Astley, S.
    BREAST CANCER RESEARCH, 2012, 14
  • [38] The TOMMY trial: a comparison of TOMosynthesis with digital MammographY in the UK NHS Breast Screening Programme a multicentre retrospective reading study comparing the diagnostic performance of digital breast tomosynthesis and digital mammography with digital mammography alone
    Gilbert, Fiona J.
    Tucker, Lorraine
    Gillan, Maureen G. C.
    Willsher, Paula
    Cooke, Julie
    Duncan, Karen A.
    Michell, Michael J.
    Dobson, Hilary M.
    Lim, Yit Yoong
    Purushothaman, Hema
    Strudley, Celia
    Astley, Susan M.
    Morrish, Oliver
    Young, Kenneth C.
    Duffy, Stephen W.
    HEALTH TECHNOLOGY ASSESSMENT, 2015, 19 (04) : 1 - +
  • [39] A comparison of reading times in full-field digital mammography and digital breast tomosynthesis
    SJ Connor
    YY Lim
    C Tate
    H Entwistle
    J Morris
    S Whiteside
    J Sergeant
    M Wilson
    U Beetles
    C Boggis
    F Gilbert
    S Astley
    Breast Cancer Research, 14
  • [40] A comparison of image interpretation times in Full Field Digital Mammography and Digital Breast Tomosynthesis
    Astley, Susan
    Connor, Sophie
    Lim, Yit
    Tate, Catriona
    Entwistle, Helen
    Morris, Julie
    Whiteside, Sigrid
    Sergeant, Jamie
    Wilson, Mary
    Beetles, Ursula
    Boggis, Caroline
    Gilbert, Fiona
    MEDICAL IMAGING 2013: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2013, 8673