Comparison of digital mammography and digital breast tomosynthesis in the detection of architectural distortion

被引:55
|
作者
Dibble, Elizabeth H. [1 ]
Lourenco, Ana P. [1 ]
Baird, Grayson L. [1 ,2 ]
Ward, Robert C. [1 ]
Maynard, A. Stanley [1 ]
Mainiero, Martha B. [1 ]
机构
[1] Brown Univ, Rhode Isl Hosp, Warren Alpert Med Sch, Dept Diagnost Imaging, Providence, RI 02903 USA
[2] Rhode Isl Hosp, Lifespan Biostat Core, 593 Eddy St, Providence, RI 02903 USA
关键词
Mammography; Breast; Early diagnosis; Digital breast tomosynthesis; Architectural distortion; SCREENING MAMMOGRAPHY; CLINICAL-EXPERIENCE; OCCULT; IMPLEMENTATION; PERFORMANCE; POPULATION; FEATURES; CANCERS; RECALL;
D O I
10.1007/s00330-017-4968-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare interobserver variability (IOV), reader confidence, and sensitivity/specificity in detecting architectural distortion (AD) on digital mammography (DM) versus digital breast tomosynthesis (DBT). This IRB-approved, HIPAA-compliant reader study used a counterbalanced experimental design. We searched radiology reports for AD on screening mammograms from 5 March 2012-27 November 2013. Cases were consensus-reviewed. Controls were selected from demographically matched non-AD examinations. Two radiologists and two fellows blinded to outcomes independently reviewed images from two patient groups in two sessions. Readers recorded presence/absence of AD and confidence level. Agreement and differences in confidence and sensitivity/specificity between DBT versus DM and attendings versus fellows were examined using weighted Kappa and generalised mixed modeling, respectively. There were 59 AD patients and 59 controls for 1,888 observations (59 x 2 (cases and controls) x 2 breasts x 2 imaging techniques x 4 readers). For all readers, agreement improved with DBT versus DM (0.61 vs. 0.37). Confidence was higher with DBT, p = .001. DBT achieved higher sensitivity (.59 vs. .32), p < .001; specificity remained high (>.90). DBT achieved higher positive likelihood ratio values, smaller negative likelihood ratio values, and larger ROC values. DBT decreases IOV, increases confidence, and improves sensitivity while maintaining high specificity in detecting AD. aEuro cent Digital breast tomosynthesis decreases interobserver variability in the detection of architectural distortion. aEuro cent Digital breast tomosynthesis increases reader confidence in the detection of architectural distortion. aEuro cent Digital breast tomosynthesis improves sensitivity in the detection of architectural distortion.
引用
收藏
页码:3 / 10
页数:8
相关论文
共 50 条
  • [1] Comparison of digital mammography and digital breast tomosynthesis in the detection of architectural distortion
    Elizabeth H. Dibble
    Ana P. Lourenco
    Grayson L. Baird
    Robert C. Ward
    A. Stanley Maynard
    Martha B. Mainiero
    European Radiology, 2018, 28 : 3 - 10
  • [2] Computer-aided detection for architectural distortion: a comparison of digital breast tomosynthesis and digital mammography
    Li, Yue
    He, Zilong
    Ma, Xiangyuan
    Zeng, Weixiong
    Liu, Jialing
    Xu, Weimin
    Xu, Zeyuan
    Wang, Sina
    Wen, Chanjuan
    Zeng, Hui
    Wu, Jiefang
    Chen, Weiguo
    Lu, Yao
    MEDICAL IMAGING 2022: COMPUTER-AIDED DIAGNOSIS, 2022, 12033
  • [3] Architectural distortion outcome: digital breast tomosynthesis-detected versus digital mammography-detected
    Shimaa Abdalla Ahmed
    Marwa Samy
    Ahmed M. Ali
    Ramy A. Hassan
    La radiologia medica, 2022, 127 : 30 - 38
  • [4] Architectural distortion outcome: digital breast tomosynthesis-detected versus digital mammography-detected
    Ahmed, Shimaa Abdalla
    Samy, Marwa
    Ali, Ahmed M.
    Hassan, Ramy A.
    RADIOLOGIA MEDICA, 2022, 127 (01): : 30 - 38
  • [5] A COMPARISON OF DIGITAL BREAST TOMOSYNTHESIS AND FULL FIELD DIGITAL MAMMOGRAPHY IN THE DETECTION OF BREAST CANCER
    Moradzadeh, A.
    Bassett, L. W.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2013, 61 (01) : 128 - 128
  • [6] Comparison of Digital Breast Tomosynthesis and Digital Mammography for Detection of Breast Cancer in Kuwaiti Women
    Asbeutah, Akram M.
    Karmani, Nouralhuda
    Asbeutah, AbdulAziz A.
    Echreshzadeh, Yasmin A.
    AlMajran, Abdullah A.
    Al-Khalifah, Khalid H.
    MEDICAL PRINCIPLES AND PRACTICE, 2019, 28 (01) : 10 - 15
  • [7] Breast Cancer Detection: Digital Breast Tomosynthesis with Synthesized Mammography versus Digital Mammography
    Ha, Su Min
    Chang, Jung Min
    RADIOLOGY, 2023, 309 (03)
  • [8] Digital Mammography and Digital Breast Tomosynthesis
    Moseley, Tanya W.
    CLINICAL OBSTETRICS AND GYNECOLOGY, 2016, 59 (02): : 362 - 379
  • [9] Comparison of synthetic and digital mammography with digital breast tomosynthesis or alone for the detection and classification of microcalcifications
    Choi, Ji Soo
    Han, Boo-Kyung
    Ko, Eun Young
    Kim, Ga Ram
    Ko, Eun Sook
    Park, Ko Woon
    EUROPEAN RADIOLOGY, 2019, 29 (01) : 319 - 329
  • [10] Comparison of synthetic and digital mammography with digital breast tomosynthesis or alone for the detection and classification of microcalcifications
    Ji Soo Choi
    Boo-Kyung Han
    Eun Young Ko
    Ga Ram Kim
    Eun Sook Ko
    Ko Woon Park
    European Radiology, 2019, 29 : 319 - 329