Optimum design of electrode structure and parameters in electrical impedance tomography

被引:24
|
作者
Yan, W [1 ]
Hong, S
Chaoshi, R
机构
[1] Chinese Acad Med Sci, Inst Biomed Engn, Tianjin 300192, Peoples R China
[2] Peking Union Med Coll, Tianjin 300192, Peoples R China
关键词
EIT; electrode structure and parameter; coercive equipotential node model; optimum design; simulation study;
D O I
10.1088/0967-3334/27/3/007
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In electrical impedance tomography (EIT) the electrode structure and parameters significantly influence measurement sensitivity and image quality, so how to optimize the electrode structure and parameters is one of the key problems in research today. This paper presents a method to optimize the EIT electrode structure and parameters based on coercive equipotential node models. The coercive equipotential mode of the compound electrode has been established based on that of the line electrode. A simulation study for the line electrode and the compound electrode of EIT has been made on a simulation software platform. The influences of different electrode structures and parameters on measurement sensitivity and the image reconstruction quality are studied. For line electrode simulation studies, two important conclusions are drawn. First, a narrower electrode is helpful in improving the imaging quality. Second, although it is known that a wider electrode is beneficial in decreasing the contact impedance, using a too wide electrode causes the measurement sensitivity to decrease. Furthermore the electrode width that leads to the best measurement sensitivity is different for different measurement depths. The compound electrode has four parameters: the excitation electrode width, the measurement electrode width, the space between the excitation electrode and the measurement electrode, and the distance between two adjacent compound electrodes. These parameters have mutual restrictions and complex influences on each other. It is unwise to optimize the design of a compound electrode by only using the overlay rate of electrodes. A simulation study of EIT electrode structure and parameter influences can be carried out according to this paper to determine the optimum design of the electrode structure and its parameters.
引用
收藏
页码:291 / 306
页数:16
相关论文
共 50 条
  • [21] Optimal Implementation Parameters of a Nonlinear Electrical Impedance Tomography Method Using the Complete Electrode Model
    Park, Jeongwoo
    Kang, Jun Won
    Choi, Eunsoo
    SENSORS, 2022, 22 (17)
  • [22] Effect of sternal electrode gap and belt rotation on the robustness of pulmonary electrical impedance tomography parameters
    Sophocleous, L.
    Waldmann, A. D.
    Becher, T.
    Kallio, M.
    Rahtu, M.
    Miedema, M.
    Papadouri, T.
    Karaoli, C.
    Tingay, D. G.
    Van Kaam, A. H.
    Yerworth, R.
    Bayford, R.
    Frerichs, I
    PHYSIOLOGICAL MEASUREMENT, 2020, 41 (03)
  • [23] Current source design for electrical impedance tomography
    Ross, AS
    Saulnier, GJ
    Newell, JC
    Isaacson, D
    PHYSIOLOGICAL MEASUREMENT, 2003, 24 (02) : 509 - 516
  • [24] The complete electrode model for imaging and electrode contact compensation in Electrical Impedance Tomography
    Boverman, Gregory
    Kim, Bong Seok
    Isaacson, David
    Newell, Jonathan C.
    Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings, 2007, : 3462 - 3465
  • [25] The complete electrode model for imaging and electrode contact compensation in electrical impedance tomography
    Boverman, Gregory
    Kim, Bong Seok
    Isaacson, David
    Newell, Jonathan C.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 3462 - +
  • [26] Determination of internal structure by electrical impedance tomography
    Univ of Newcastle upon Tyne, United Kingdom
    Nondestr Test Eval, 3 (173-181):
  • [27] A Mismatch Correction Method for Electrode Offset in Electrical Impedance Tomography
    Shi, Yanyan
    Lou, Yajun
    Wang, Meng
    Tian, Zhiwei
    Yang, Bin
    Fu, Feng
    IEEE SENSORS JOURNAL, 2022, 22 (07) : 7248 - 7257
  • [28] Imaging of electrode movement and conductivity change in Electrical Impedance Tomography
    Gomez-Laberge, Camille
    Adler, Andy
    2006 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-5, 2006, : 1029 - +
  • [29] A New Method for Electrical Impedance Tomography With Incomplete Electrode Array
    Sun, Benyuan
    Zhao, Yu
    Zhong, Hangyu
    Ma, Long
    Wang, Huaxiang
    IEEE SENSORS JOURNAL, 2023, 23 (18) : 21610 - 21619
  • [30] IMAGING OF ELECTRODE MOVEMENT AND CONDUCTIVITY CHANGE IN ELECTRICAL IMPEDANCE TOMOGRAPHY
    Quan, Wan
    Dinh, Anh
    2006 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-5, 2006, : 1033 - +