In-operation modal analysis of containments using ambient vibration

被引:5
|
作者
Choi, Sanghyun
Park, Sooyong [1 ,2 ]
Hyun, Chang-Hun [3 ]
Kim, Moon-Soo [4 ]
机构
[1] Korea Natl Univ Transportat, Dept Railroad Facil Engn, Uiwang 437763, Gyeonggi Do, South Korea
[2] Korea Maritime Univ, Dept Architecture & Ocean Space, Pusan 606791, South Korea
[3] Korea Inst Nucl Safety, Struct Syst & Site Evaluat, Taejon 305600, South Korea
[4] Korea Inst Nucl Safety, Mech Struct & Mat Engn Dept, Taejon 305600, South Korea
关键词
ATUCHA-II NPP; IDENTIFICATION; BUILDINGS; TESTS; SIMULATION; FREQUENCY; DAMAGE;
D O I
10.1016/j.nucengdes.2013.01.027
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The importance of preserving the structural integrity of a containment can never be overemphasized. Currently the structural integrity of the containment is evaluated periodically via various nondestructive inspection methods. However, these methods can only provide local integrity data, and cannot deliver continuous monitoring information on overall structural integrity. In this paper, the result of a feasibility study on utilizing ambient vibration measurements to monitor the structural integrity of a containment is presented. The ambient vibration testing was selected, because it can avoid the interruption of normal operation of power plants. For the purpose of the study, the ambient vibration of four different containments in Korea, i.e. Ulchin Unit 5, Wolsong Unit 2, Ulchin Unit 1, and Yeonggwang Unit 4, was measured and modal parameters were extracted via frequency domain modal analysis techniques. The experimental modes were then compared to the analytical modes estimated using finite element analysis to examine the correlation, and highly correlated modes were adopted in identifying structural parameters using a system identification method. The structural parameter selected in this study was the elastic modulus of the concrete, and the identified moduli were compared to design values and inspection results. The result shows the ambient vibration can be utilized in monitoring the structural integrity of a containment, though further extensive study needs to be conducted to identify and exclude the effect of ambient conditions such as temperature and humidity on resonant frequencies. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:16 / 29
页数:14
相关论文
共 50 条
  • [41] Structural finite element model updating using incomplete ambient vibration modal data
    Chen HuaPeng
    Tee KongFah
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2014, 57 (09) : 1677 - 1688
  • [42] Identification of modal parameters from nonstationary ambient vibration data using correlation technique
    Chiang, Dar-Yun
    Lin, Chang-Sheng
    AIAA Journal, 2008, 46 (11): : 2752 - 2759
  • [43] Structural finite element model updating using incomplete ambient vibration modal data
    CHEN HuaPeng
    TEE KongFah
    Science China(Technological Sciences), 2014, 57 (09) : 1677 - 1688
  • [44] Modal analysis and ambient vibration measurements on Mila-Algeria cable stayed bridge
    Kibboua, Abderrahmane
    Farsi, Mohamed Naboussi
    Chatelain, Jean-Luc
    Guillier, Bertrand
    Bechtoula, Hakim
    Mehani, Youcef
    STRUCTURAL ENGINEERING AND MECHANICS, 2008, 29 (02) : 171 - 186
  • [45] Structural damage assessment using vibration modal analysis
    Khoo, LM
    Mantena, PR
    Jadhav, P
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2004, 3 (02): : 177 - 194
  • [46] Bayesian strain modal analysis under ambient vibration and damage identification using distributed fiber Bragg grating sensors
    Zhang, Yanhui
    Yang, Wenyu
    SENSORS AND ACTUATORS A-PHYSICAL, 2013, 201 : 434 - 449
  • [47] Autonomous structural health monitoring - Part II: Vibration-based in-operation damage assessment
    Parloo, E
    Verboven, P
    Guillaume, P
    Van Overmeire, M
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2002, 16 (04) : 659 - 675
  • [48] Model-based structural identification and monitoring using in-operation data
    Balmès, É
    Basseville, M
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 1999, 13 (06) : 821 - 821
  • [49] Identification of Modal Parameters of a Multistoried RC Building Using Ambient Vibration and Strong Vibration Records of Bhuj Earthquake, 2001
    Singh, J. P.
    Agarwal, Pankaj
    Kumar, Ashok
    Thakkar, S. K.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2014, 18 (03) : 444 - 457
  • [50] EXTENDING BLIND MODAL IDENTIFICATION TO THE UNDERDETERMINED CASE FOR AMBIENT VIBRATION
    McNeill, Scot
    INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 12, 2013, : 241 - 252