In-operation modal analysis of containments using ambient vibration

被引:5
|
作者
Choi, Sanghyun
Park, Sooyong [1 ,2 ]
Hyun, Chang-Hun [3 ]
Kim, Moon-Soo [4 ]
机构
[1] Korea Natl Univ Transportat, Dept Railroad Facil Engn, Uiwang 437763, Gyeonggi Do, South Korea
[2] Korea Maritime Univ, Dept Architecture & Ocean Space, Pusan 606791, South Korea
[3] Korea Inst Nucl Safety, Struct Syst & Site Evaluat, Taejon 305600, South Korea
[4] Korea Inst Nucl Safety, Mech Struct & Mat Engn Dept, Taejon 305600, South Korea
关键词
ATUCHA-II NPP; IDENTIFICATION; BUILDINGS; TESTS; SIMULATION; FREQUENCY; DAMAGE;
D O I
10.1016/j.nucengdes.2013.01.027
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The importance of preserving the structural integrity of a containment can never be overemphasized. Currently the structural integrity of the containment is evaluated periodically via various nondestructive inspection methods. However, these methods can only provide local integrity data, and cannot deliver continuous monitoring information on overall structural integrity. In this paper, the result of a feasibility study on utilizing ambient vibration measurements to monitor the structural integrity of a containment is presented. The ambient vibration testing was selected, because it can avoid the interruption of normal operation of power plants. For the purpose of the study, the ambient vibration of four different containments in Korea, i.e. Ulchin Unit 5, Wolsong Unit 2, Ulchin Unit 1, and Yeonggwang Unit 4, was measured and modal parameters were extracted via frequency domain modal analysis techniques. The experimental modes were then compared to the analytical modes estimated using finite element analysis to examine the correlation, and highly correlated modes were adopted in identifying structural parameters using a system identification method. The structural parameter selected in this study was the elastic modulus of the concrete, and the identified moduli were compared to design values and inspection results. The result shows the ambient vibration can be utilized in monitoring the structural integrity of a containment, though further extensive study needs to be conducted to identify and exclude the effect of ambient conditions such as temperature and humidity on resonant frequencies. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:16 / 29
页数:14
相关论文
共 50 条
  • [31] Ambient vibration testing & modal identification of an office building
    Tamura, Y
    Zhang, LM
    Yoshida, A
    Cho, K
    Nakata, S
    Naito, S
    PROCEEDINGS OF IMAC-XX: STRUCTURAL DYNAMICS VOLS I AND II, 2002, 4753 : 141 - 146
  • [32] Modal Identification through Ambient Vibration: Comparative Study
    Giraldo, Diego F.
    Song, Wei
    Dyke, Shirley J.
    Caicedo, Juan M.
    JOURNAL OF ENGINEERING MECHANICS, 2009, 135 (08) : 759 - 770
  • [33] On modal parameter estimates from ambient vibration tests
    Agneni, A.
    Brincker, R.
    Coppotelli, G.
    Proceedings of ISMA 2004: International Conference on Noise and Vibration Engineering, Vols 1-8, 2005, : 2239 - 2248
  • [34] In-operation structural damage detection using maximum likelihood techniques
    Parloo, E
    Guillaume, P
    Van Overmeire, M
    IMAC-XVIII: A CONFERENCE ON STRUCTURAL DYNAMICS, VOLS 1 AND 2, PROCEEDINGS, 2000, 4062 : 1563 - 1569
  • [35] Failure analysis of a cooling pump using modal and vibration analysis
    Hazelwood, Thomas
    Van Hoy, Blake
    International Journal of COMADEM, 2020, 23 (03): : 11 - 15
  • [36] In-operation structural damage detection using maximum likelihood techniques
    Parloo, E.
    Guillaume, P.
    Van Overmeire, M.
    2000, SEM, United States (02):
  • [37] Hybrid time and frequency domain technique on modal identification using ambient vibration tests
    Kuroiwa, Tatiana
    Iemura, Hirokazu
    Structural Engineering/Earthquake Engineering, 2009, 26 (02)
  • [38] Structural finite element model updating using incomplete ambient vibration modal data
    HuaPeng Chen
    KongFah Tee
    Science China Technological Sciences, 2014, 57 : 1677 - 1688
  • [39] Identification of Modal Parameters from Nonstationary Ambient Vibration Data Using Correlation Technique
    Chiang, Dar-Yun
    Lin, Chang-Sheng
    AIAA JOURNAL, 2008, 46 (11) : 2752 - 2759
  • [40] Structural finite element model updating using incomplete ambient vibration modal data
    CHEN HuaPeng
    TEE KongFah
    Science China(Technological Sciences), 2014, (09) : 1677 - 1688