Effects of heat and moisture exchangers on minute ventilation, ventilatory drive, and work of breathing during pressure-support ventilation in acute respiratory failure

被引:57
|
作者
Pelosi, P
Solca, M
Ravagnan, I
Tubiolo, D
Ferrario, L
Gattinoni, L
机构
[1] Istituto di Anestesia e Rianimazione, Universita' degli Studi di Milano, IRCCS Ospedale Maggiore, Milano
[2] Istituto di Anestesia e Rianimazione, Universita' degli Studi di Milano, IRCCS Ospedale Maggiore di Milano, 20122 Milano
关键词
acute respiratory failure; artificial ventilation; work of breathing; mechanical ventilation; respiratory function; respiratory deadspace; lungs; critical illness; pulmonary emergencies;
D O I
10.1097/00003246-199607000-00020
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To evaluate the effect of two commonly used heat and moisture exchangers on respiratory function and gas ex change in patients with acute respiratory failure during pressure-support ventilation. Design: Prospective, randomized trial. Setting: Intensive care unit of a university hospital. Patients: Fourteen patients with moderate acute respiratory failure, receiving pressure support ventilation. Interventions: Patients were assigned randomly to two treatment groups, in which two different heat and moisture exchangers were used: Hygroster(R)(DAR S.p.A., Mirandola, Italy) with higher deadspace and lower resistance (group 1, n = 7), and Hygrobac-S(R)(DAR S.p.A.) with lower deadspace and higher resistance (group 2, n = 7). Patients were assessed at three pressure-support levels: a) baseline (10.3 +/- 2.4 cm H2O for group 1, 9.3 +/- 1.3 cm H2O for group 2); b)5 cm H2O above baseline; and c)5 cm H2O below baseline. Measurements obtained with the heat and moisture exchangers were compared with those values obtained using the standard heated hot water humidifier. Measurements and Main Results: At baseline pressure-support ventilation, the insertion of both heat and moisture exchangers induced in all patients a significant increase in the following parameters: minute ventilation (12.4 +/- 3.2 to 15.0 +/- 2.6 L/min for group 1, and 11.8 +/- 3.6 to 14.2 +/- 3.5 L/min for group 2); static intrinsic positive end expiratory pressure (2.9 +/- 2.0 to 5.1 +/- 3.2 cm H2O for group 1, and 2.9 +/- 1.7 to 5.5 +/- 3.0 cm H2O for group 2); ventilatory drive, expressed as P-0.1 (2.7 +/- 2.0 to 5.2 +/- 4.0 cm H2O for group 1, and 3.3 +/- 2.0 to 5.3 +/- 3.0 cm H2O for group 2); and work of breathing, expressed as either power (8.8 +/- 9.4 to 14.5 +/- 10.3 joule/min for group 1, and 10.5 +/- 7.4 to 16.8 +/- 11.0 joule/min for group 2) or work per liter of ventilation (0.6 +/- 0.6 to 1.0 +/- 0.7 joule/L. for group 1, and 0.8 +/- 0.4 to 1.1 +/- 0.5 joule/L for group 2). These increases also occurred when pressure-support ventilation was both above and below the baseline level, although at high pres sure support the increase in work of breathing with heat and moisture exchangers was less evident. Gas exchange was unaffected by heat and moisture exchangers, as minute ventilation increased to compensate for the higher deadspace produced in the circuit by the insertion of heat and moisture exchangers. Conclusions: The tested heat and moisture exchangers should be used carefully in patients with acute respiratory failure during pressure-support ventilation, since these devices substantially increase minute ventilation, ventilatory drive, and work of breathing. However, an increase in pressure-support ventilation (5 to 10 cm H2O) may compensate for the increased work of breathing.
引用
收藏
页码:1184 / 1188
页数:5
相关论文
共 50 条
  • [41] Effects of connecting tubes and swivels on the breathing pattern and work of breathing during pressure support ventilation: a laboratory and simulation study
    C Stahl
    S Schumann
    C Haas
    K Möller
    J Guttmann
    Critical Care, 10 (Suppl 1):
  • [42] Respiratory muscle pressure: A very good predictor of work of breathing and a guide for setting pressure support ventilation
    Banner, MJ
    vanOostrom, JH
    Blanch, PB
    Melker, RJ
    Kirby, RR
    ANESTHESIOLOGY, 1996, 85 (3A) : A272 - A272
  • [43] Effects of pressure-support ventilation with different levels of positive end-expiratory in a mild model of acute respiratory distress syndrome
    PAF Magalhães
    GDA Padilha
    L Moraes
    CL Santos
    LB de Andrade
    MGPdA Magalhães
    MDCMB Duarte
    PRM Rocco
    PL Silva
    Intensive Care Medicine Experimental, 3 (Suppl 1)
  • [44] Comparison of the effects of heat and moisture exchangers and heated humidifiers on ventilation and gas exchange during non-invasive ventilation
    Jaber, S
    Chanques, G
    Matecki, S
    Ramonatxo, M
    Souche, B
    Perrigault, PF
    Eledjam, JJ
    INTENSIVE CARE MEDICINE, 2002, 28 (11) : 1590 - 1594
  • [45] Comparison of the effects of heat and moisture exchangers and heated humidifiers on ventilation and gas exchange during non-invasive ventilation
    Samir Jaber
    Gérald Chanques
    Stefan Matecki
    Michèle Ramonatxo
    Bruno Souche
    Pierre-François Perrigault
    Jean-Jacques Eledjam
    Intensive Care Medicine, 2002, 28 : 1590 - 1594
  • [46] Noninvasive pressure support versus proportional assist ventilation in acute respiratory failure
    Fernández-Vivas, M
    Caturla-Such, J
    de la Rosa, JG
    Acosta-Escribano, J
    Alvarez-Sánchez, B
    Cánovas-Robles, J
    INTENSIVE CARE MEDICINE, 2003, 29 (07) : 1126 - 1133
  • [47] Noninvasive pressure support versus proportional assist ventilation in acute respiratory failure
    Miguel Fernández-Vivas
    Juan Caturla-Such
    Javier González de la Rosa
    José Acosta-Escribano
    Bernabé Álvarez-Sánchez
    José Cánovas-Robles
    Intensive Care Medicine, 2003, 29 : 1126 - 1133
  • [48] WORK OF BREATHING DURING PRESSURE SUPPORT VENTILATION AFFECTED BY RISES IN PRESSURE AND FLOW-RATE
    BANNER, MJ
    BLANCH, PB
    KIRBY, RR
    ANESTHESIOLOGY, 1994, 81 (3A) : A270 - A270
  • [49] PRESSURE SUPPORT VENTILATION WITH A SIMPLIFIED VENTILATORY SUPPORT SYSTEM ADMINISTERED WITH A NASAL MASK IN PATIENTS WITH RESPIRATORY-FAILURE
    PENNOCK, BE
    KAPLAN, PD
    CARLIN, BW
    SABANGAN, JS
    MAGOVERN, JA
    CHEST, 1991, 100 (05) : 1371 - 1376
  • [50] Effects of different fluid management on lung and kidney during pressure-controlled and pressure-support ventilation in experimental acute lung injury
    de Carvalho, Eduardo Butturini
    Fernandes Fonseca, Ana Carolina
    Magalhaes, Raquel Ferreira
    Pinto, Eliete Ferreira
    Samary, Cynthia dos Santos
    Antunes, Mariana Alves
    Baldavira, Camila Machado
    Ramos da Silveira, Lizandre Keren
    Teodoro, Walcy Rosolia
    de Abreu, Marcelo Gama
    Capelozzi, Vera Luiza
    Felix, Nathane Santanna
    Pelosi, Paolo
    Macedo Rocco, Patricia Rieken
    Silva, Pedro Leme
    PHYSIOLOGICAL REPORTS, 2022, 10 (17):