Effects of heat and moisture exchangers on minute ventilation, ventilatory drive, and work of breathing during pressure-support ventilation in acute respiratory failure

被引:57
|
作者
Pelosi, P
Solca, M
Ravagnan, I
Tubiolo, D
Ferrario, L
Gattinoni, L
机构
[1] Istituto di Anestesia e Rianimazione, Universita' degli Studi di Milano, IRCCS Ospedale Maggiore, Milano
[2] Istituto di Anestesia e Rianimazione, Universita' degli Studi di Milano, IRCCS Ospedale Maggiore di Milano, 20122 Milano
关键词
acute respiratory failure; artificial ventilation; work of breathing; mechanical ventilation; respiratory function; respiratory deadspace; lungs; critical illness; pulmonary emergencies;
D O I
10.1097/00003246-199607000-00020
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To evaluate the effect of two commonly used heat and moisture exchangers on respiratory function and gas ex change in patients with acute respiratory failure during pressure-support ventilation. Design: Prospective, randomized trial. Setting: Intensive care unit of a university hospital. Patients: Fourteen patients with moderate acute respiratory failure, receiving pressure support ventilation. Interventions: Patients were assigned randomly to two treatment groups, in which two different heat and moisture exchangers were used: Hygroster(R)(DAR S.p.A., Mirandola, Italy) with higher deadspace and lower resistance (group 1, n = 7), and Hygrobac-S(R)(DAR S.p.A.) with lower deadspace and higher resistance (group 2, n = 7). Patients were assessed at three pressure-support levels: a) baseline (10.3 +/- 2.4 cm H2O for group 1, 9.3 +/- 1.3 cm H2O for group 2); b)5 cm H2O above baseline; and c)5 cm H2O below baseline. Measurements obtained with the heat and moisture exchangers were compared with those values obtained using the standard heated hot water humidifier. Measurements and Main Results: At baseline pressure-support ventilation, the insertion of both heat and moisture exchangers induced in all patients a significant increase in the following parameters: minute ventilation (12.4 +/- 3.2 to 15.0 +/- 2.6 L/min for group 1, and 11.8 +/- 3.6 to 14.2 +/- 3.5 L/min for group 2); static intrinsic positive end expiratory pressure (2.9 +/- 2.0 to 5.1 +/- 3.2 cm H2O for group 1, and 2.9 +/- 1.7 to 5.5 +/- 3.0 cm H2O for group 2); ventilatory drive, expressed as P-0.1 (2.7 +/- 2.0 to 5.2 +/- 4.0 cm H2O for group 1, and 3.3 +/- 2.0 to 5.3 +/- 3.0 cm H2O for group 2); and work of breathing, expressed as either power (8.8 +/- 9.4 to 14.5 +/- 10.3 joule/min for group 1, and 10.5 +/- 7.4 to 16.8 +/- 11.0 joule/min for group 2) or work per liter of ventilation (0.6 +/- 0.6 to 1.0 +/- 0.7 joule/L. for group 1, and 0.8 +/- 0.4 to 1.1 +/- 0.5 joule/L for group 2). These increases also occurred when pressure-support ventilation was both above and below the baseline level, although at high pres sure support the increase in work of breathing with heat and moisture exchangers was less evident. Gas exchange was unaffected by heat and moisture exchangers, as minute ventilation increased to compensate for the higher deadspace produced in the circuit by the insertion of heat and moisture exchangers. Conclusions: The tested heat and moisture exchangers should be used carefully in patients with acute respiratory failure during pressure-support ventilation, since these devices substantially increase minute ventilation, ventilatory drive, and work of breathing. However, an increase in pressure-support ventilation (5 to 10 cm H2O) may compensate for the increased work of breathing.
引用
收藏
页码:1184 / 1188
页数:5
相关论文
共 50 条
  • [21] MECHANICAL VENTILATORS OPTIMIZED FOR PEDIATRIC USE DECREASE WORK OF BREATHING AND OXYGEN-CONSUMPTION DURING PRESSURE-SUPPORT VENTILATION
    HEULITT, MJ
    CARMACK, J
    ANDERS, M
    CRITICAL CARE MEDICINE, 1995, 23 (11) : 1931 - 1932
  • [22] Noninvasive pressure support ventilation for acute respiratory failure in children
    Rimensberger, PC
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 2000, 130 (49) : 1880 - 1886
  • [23] Acute effects of hyperoxemia on dyspnoea and respiratory variables during pressure support ventilation
    Volta, CA
    Alvisi, V
    Bertacchini, S
    Marangoni, E
    Ragazzi, R
    Verri, M
    Alvisi, R
    INTENSIVE CARE MEDICINE, 2006, 32 (02) : 223 - 229
  • [24] Acute effects of hyperoxemia on dyspnoea and respiratory variables during pressure support ventilation
    Carlo Alberto Volta
    Valentina Alvisi
    Sara Bertacchini
    Elisabetta Marangoni
    Riccardo Ragazzi
    Marco Verri
    Raffaele Alvisi
    Intensive Care Medicine, 2006, 32 : 223 - 229
  • [25] Physiological comparison of breathing patterns with neurally adjusted ventilatory assist (NAVA) and pressure-support ventilation to improve NAVA settings
    Meric, Henri
    Calabrese, Pascale
    Pradon, Didier
    Lejaille, Michele
    Lofaso, Frederic
    Terzi, Nicolas
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2014, 195 : 11 - 18
  • [26] Correlation Between the %MinVol Setting and Work of Breathing During Adaptive Support Ventilation in Patients with Respiratory Failure
    Wu, Chin-Pyng
    Lin, Hen-I
    Perng, Wann-Chern
    Yang, Shih-Hsing
    Chen, Chien-Wen
    Huang, Yuh-Chin T.
    Huang, Kun-Lun
    RESPIRATORY CARE, 2010, 55 (03) : 334 - 341
  • [27] Respiratory response to CO2 during pressure-support ventilation in conscious normal humans
    Georgopoulos, D
    Mitrouska, I
    Bshouty, Z
    Webster, K
    Patakas, D
    Younes, M
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 156 (01) : 146 - 154
  • [28] COMPARISON OF PRESSURE SUPPORT VENTILATION AND ASSIST CONTROL VENTILATION IN PATIENTS WITH ACUTE RESPIRATORY-FAILURE
    TOKIOKA, H
    SAITO, S
    KOSAKA, F
    INTENSIVE CARE MEDICINE, 1989, 15 (06) : 364 - 367
  • [29] PATIENT AND VENTILATOR WORK OF BREATHING AND VENTILATORY MUSCLE LOADS AT DIFFERENT LEVELS OF PRESSURE SUPPORT VENTILATION
    BANNER, MJ
    KIRBY, RR
    MACINTYRE, NR
    CHEST, 1991, 100 (02) : 531 - 533
  • [30] Effects of Inspiratory Rise Time on Triggering Work Load During Pressure-Support Ventilation: A Lung Model Study
    Murata, Shinya
    Yokoyama, Kazuki
    Sakamoto, Yushi
    Yamashita, Ken
    Oto, Jun
    Imanaka, Hideaki
    Nishimura, Masaji
    RESPIRATORY CARE, 2010, 55 (07) : 878 - 884