Validity of ultrasonograph muscle thickness measurements for estimating muscle volume of knee extensors in humans

被引:114
|
作者
Miyatani, M
Kanehisa, H
Kuno, S
Nishijima, T
Fukunaga, T
机构
[1] Univ Tokyo, Dept Life Sci Sports Sci, Meguro Ku, Tokyo 1538902, Japan
[2] Univ Tsukuba, Ctr Tsukuba Adv Res Alliance, TARA, Tsukuba, Ibaraki 3058574, Japan
[3] Univ Tsukuba, Inst Hlth & Sports Sci, Tsukuba, Ibaraki 3058574, Japan
关键词
brightness mode ultrasound; magnetic resonance imaging; quadriceps femoris muscle; field research;
D O I
10.1007/s00421-001-0533-9
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
This study aimed to investigate the suitability of using ultrasonograph muscle thickness (MT) measurements to estimate the muscle volume (MV) of the quadriceps femoris as an alternative approach to magnetic resonance imaging (MRI). The subjects were 46 men aged from 20 to 70 years who were randomly allocated to either a validation or a cross-validation group, In the validation group, multiple and simple regression equations, which used a set of MT values determined at mid-thigh and thigh length (1) and the product of pi. (MT/2)(2). and 1 [pi.(MT/2)(2).1]. respectively, as independent variables, were derived to estimate the MV measured by MRI. Because the two equations were cross-validated, the data from the two groups were pooled to generate the final prediction equations: MV (cm(3))=(MT x 311.732)+(1 x 53,346) -2058.529 as the multiple regression equation and MV (cm(3)) = [pi.(MT/ 2)(2).1] x 1.1176 663.040 as the simple regression equation. In the multiple regression equation, NIT explained 75% of the variation in the MV measured by MRI. The r(2) and the standard error of the estimate (SEE) of the equations were 0.824 and 175.6 cm(3) (10.6%), respectively. for the multiple regression equation and 0.829 and 173.7 cm(3) (10.5%), respectively, for the simple regression equation. Thus. the present results indicate that ultrasonograph NIT measurements at mid-thigh are useful for estimating the MV of knee extensors. However, the observed SEE values suggest that the prediction equation obtained in this study may be limited to population studies rather than individual assessments in longitudinal studies.
引用
收藏
页码:203 / 208
页数:6
相关论文
共 50 条
  • [1] Validity of ultrasonograph muscle thickness measurements for estimating muscle volume of knee extensors in humans
    Masae Miyatani
    Hiroaki Kanehisa
    Shinya Kuno
    Takahiko Nishijima
    Tetsuo Fukunaga
    European Journal of Applied Physiology, 2002, 86 : 203 - 208
  • [2] Relationship between muscle volume and contractile properties of the human knee extensors
    Behrens, Martin
    Brown, Niklas
    Bollinger, Robert
    Bubeck, Dieter
    Mau-Moeller, Anett
    Weippert, Matthias
    Zschorlich, Volker
    Bruhn, Sven
    Alt, Wilfried
    APPLIED PHYSIOLOGY NUTRITION AND METABOLISM, 2016, 41 (01) : 110 - 113
  • [3] Validity of estimating limb muscle volume by bioelectrical impedance
    Miyatani, M
    Kanehisa, H
    Masuo, Y
    Ito, M
    Fukunaga, T
    JOURNAL OF APPLIED PHYSIOLOGY, 2001, 91 (01) : 386 - 394
  • [4] The Relationship Between Spasticity and Muscle Volume of the Knee Extensors in Children With Cerebral Palsy
    Pierce, Samuel R.
    Prosser, Laura A.
    Lee, Samuel C. K.
    Lauer, Richard T.
    PEDIATRIC PHYSICAL THERAPY, 2012, 24 (02) : 177 - 181
  • [5] ENHANCING THE EXAMINER'S RESISTING FORCE IMPROVES THE VALIDITY OF MANUAL MUSCLE STRENGTH MEASUREMENTS: APPLICATION TO KNEE EXTENSORS AND FLEXORS
    Lu, Tung-Wu
    Chien, Hui-Lien
    Chang, Ling-Ying
    Hsu, Horng-Chaung
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2012, 26 (09) : 2364 - 2371
  • [6] Estimation of Validity of A-Mode Ultrasound for Measurements of Muscle Thickness and Muscle Quality
    Lee, Ji-Won
    Hong, Seung-Ug
    Lee, Ju-Hee
    Park, Sung-Yun
    BIOENGINEERING-BASEL, 2024, 11 (02):
  • [7] Effects of growth on muscle architecture of knee extensors
    Mogi, Yasuyoshi
    Wakahara, Taku
    JOURNAL OF ANATOMY, 2022, 241 (03) : 683 - 691
  • [8] Sex differences in muscle morphology of the knee flexors and knee extensors
    Behan, Fearghal P.
    Maden-Wilkinson, Thomas M.
    Pain, Matt T. G.
    Folland, Jonathan P.
    PLOS ONE, 2018, 13 (01):
  • [9] Commentary on "The Relationship Between Spasticity and Muscle Volume of the Knee Extensors in Children With Cerebral Palsy"
    Nervick, Deborah
    Parent-Nichols, Jennifer
    PEDIATRIC PHYSICAL THERAPY, 2012, 24 (02) : 182 - 182
  • [10] Reliability and Validity of Quadriceps Muscle Thickness Measurements in Ultrasonography: A Comparison with Muscle Mass and Strength
    Ogawa, Masato
    Matsumoto, Tsuyoshi
    Harada, Risa
    Yoshikawa, Ryo
    Ueda, Yuya
    Takamiya, Daiki
    Sakai, Yoshitada
    PROGRESS IN REHABILITATION MEDICINE, 2023, 8