Estimation of Validity of A-Mode Ultrasound for Measurements of Muscle Thickness and Muscle Quality

被引:1
|
作者
Lee, Ji-Won [1 ]
Hong, Seung-Ug [2 ]
Lee, Ju-Hee [3 ]
Park, Sung-Yun [4 ]
机构
[1] Dongguk Univ, Grad Sch, Dept Korean Med, Goyang 10326, South Korea
[2] Dongguk Univ, Coll Korean Med, Dept Ophthalmol Otolaryngol & Dermatol, Goyang 10326, South Korea
[3] Dongguk Univ, Coll Korean Med, Goyang 10326, South Korea
[4] Dongguk Univ, Coll Korean Med, Dept Diagnost, Goyang 10326, South Korea
来源
BIOENGINEERING-BASEL | 2024年 / 11卷 / 02期
基金
新加坡国家研究基金会;
关键词
amplitude modulation; muscle thickness; muscle quality; subcutaneous fat thickness;
D O I
10.3390/bioengineering11020149
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
This study aimed to determine whether amplitude modulation (A-mode) ultrasound (US) provides accurate and reliable measurements comparable to those obtained using brightness modulation (B-mode) US under diverse conditions. Thirty healthy participants (15 women and 15 men) underwent measurements of subcutaneous fat thickness (SFT), muscle thickness (MT), and muscle quality (MQ) in the trapezius and biceps brachii muscles using both US modes before and after exercises designed to stimulate the respective muscles. Among the three key indices, the results demonstrated the high validity of the A-mode, with minimal mean differences (MDs) between the two devices less than 0.91 mm and intra-class correlation coefficients (ICCs) exceeding 0.95 for all measures. In addition, the correlation coefficients between the error scores and average scores for the trapezius and biceps brachii suggested no evidence of systematic error. The trapezius MT and MQ significantly increased, and the biceps brachii MT significantly increased after the exercises (p < 0.05). Notably, both the A- and B-modes exhibited the same trend in these post-exercise changes in the muscle. This study suggests that low-cost and low-resolution A-mode US provides measurements of SFT, MT, and MQ similar to the more expensive, high-resolution B-mode imaging. A-mode US is an affordable and portable alternative for muscle assessment.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] A-Mode Ultrasound Reliability in Fat and Muscle Thickness Measurement
    Ribeiro, Guilherme
    de Aguiar, Rafael A.
    Penteado, Rafael
    Lisboa, Felipe D.
    Raimundo, Joao A. G.
    Loch, Thiago
    Meira, Angelo
    Turnes, Tiago
    Caputo, Fabrizio
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2022, 36 (06) : 1610 - 1617
  • [2] A comparison of acute changes in muscle thickness between A-mode and B-mode ultrasound
    Kuehne, Tayla E.
    Yitzchaki, Noam
    Jessee, Matthew B.
    Graves, B. Sue
    Buckner, Samuel L.
    PHYSIOLOGICAL MEASUREMENT, 2019, 40 (11)
  • [3] The concurrent validity of a portable ultrasound probe for muscle thickness measurements
    Homer, Kai A.
    Cross, Matt R.
    Jukic, Ivan
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2025, 45 (01)
  • [4] Exercise-induced Changes In Muscle Thickness As Measured By Both A-mode And B-mode Ultrasound
    Kuehne, Tayla E.
    Yitzchaki, Noam
    Graves, B. Sue
    Buckner, Samuel L.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 336 - 336
  • [5] The validity of ultrasound estimation of muscle volumes
    Infantolino, Benjamin W.
    Gales, Daniel J.
    Winter, Samantha L.
    Challis, John H.
    JOURNAL OF APPLIED BIOMECHANICS, 2007, 23 (03) : 213 - 217
  • [6] Stimulation-Induced Muscle Deformation Measured With A-Mode Ultrasound Correlates With Muscle Fatigue
    Alvarez, Jonathan T.
    Jin, Yichu
    Choe, Dabin K.
    Suitor, Elizabeth L.
    Walsh, Conor J.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2025, 33 : 10 - 21
  • [7] Reliability of Muscle Thickness Measurements Using Ultrasound
    Chagas Gomes, Paulo Sergio
    Meirelles, Claudia de Mello
    Leite, Sandra Pereira
    Barbosa Montenegro, Carlos Antonio
    REVISTA BRASILEIRA DE MEDICINA DO ESPORTE, 2010, 16 (01) : 41 - 45
  • [8] Comparative Analysis of Wearable A-Mode Ultrasound and sEMG for Muscle-Computer Interface
    Yang, Xingchen
    Yan, Jipeng
    Liu, Honghai
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (09) : 2434 - 2442
  • [9] Reliability and Validity of A-Mode Ultrasound to Quantify Body Composition
    Hendrickson, Nathan
    Davison, John
    Schiller, Luke
    Willey, Michael
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 (09) : 472 - 477
  • [10] Automatic Estimation of Biceps Brachi Muscle Thickness in B-Mode Ultrasound Images
    He, Keshi
    Ye, Linwei
    Sun, Xueli
    Yang, Xingchen
    Liu, Honghai
    2018 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2018, : 4326 - 4330