摘要
This study aimed to determine whether amplitude modulation (A-mode) ultrasound (US) provides accurate and reliable measurements comparable to those obtained using brightness modulation (B-mode) US under diverse conditions. Thirty healthy participants (15 women and 15 men) underwent measurements of subcutaneous fat thickness (SFT), muscle thickness (MT), and muscle quality (MQ) in the trapezius and biceps brachii muscles using both US modes before and after exercises designed to stimulate the respective muscles. Among the three key indices, the results demonstrated the high validity of the A-mode, with minimal mean differences (MDs) between the two devices less than 0.91 mm and intra-class correlation coefficients (ICCs) exceeding 0.95 for all measures. In addition, the correlation coefficients between the error scores and average scores for the trapezius and biceps brachii suggested no evidence of systematic error. The trapezius MT and MQ significantly increased, and the biceps brachii MT significantly increased after the exercises (p < 0.05). Notably, both the A- and B-modes exhibited the same trend in these post-exercise changes in the muscle. This study suggests that low-cost and low-resolution A-mode US provides measurements of SFT, MT, and MQ similar to the more expensive, high-resolution B-mode imaging. A-mode US is an affordable and portable alternative for muscle assessment.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Validity and Reliability of A-Mode Ultrasound for Body Composition Assessment of NCAA Division I Athletes
    Wagner, Dale R.
    Cain, Dustin L.
    Clark, Nicolas W.
    PLOS ONE, 2016, 11 (04):
  • [42] Prediction of the muscle strength by the muscle thickness and hardness using ultrasound muscle hardness meter
    Muraki, Satoshi
    Fukumoto, Kiyotaka
    Fukuda, Osamu
    SPRINGERPLUS, 2013, 2 : 1 - 7
  • [43] A-mode and B-mode Ultrasound Measurement of Subcutaneous Fat Thickness: A Cadaver Analysis Validation Study
    Wagner, Dale R.
    Thompson, Brennan J.
    Anderson, D. Andy
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (05): : 257 - 257
  • [44] Reliability of muscle thickness measurements in ultrasonography
    Barotsis, Nikolaos
    Tsiganos, Panagiotis
    Kokkalis, Zinon
    Panayiotakis, George
    Panagiotopoulos, Elias
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2020, 43 (02) : 123 - 128
  • [45] Quantitative peripheral muscle ultrasound in sepsis: Muscle area superior to thickness
    Palakshappa, Jessica A.
    Reilly, John P.
    Schweickert, William D.
    Anderson, Brian J.
    Khoury, Viviane
    Shashaty, Michael G.
    Fitzgerald, David
    Forker, Caitlin
    Butler, Kelly
    Ittner, Caroline A.
    Feng, Rui
    Files, D. Clark
    Bonk, Michael P.
    Christie, Jason D.
    Meyer, Nuala J.
    JOURNAL OF CRITICAL CARE, 2018, 47 : 324 - 330
  • [46] Muscle Ultrasound As a Link to Muscle Quality and Frailty in the Clinic
    Bartley, Jenna M.
    Studenski, Stephanie A.
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2017, 65 (12) : 2562 - 2563
  • [47] Comparison of ultrasound muscle thickness measurements in ICU patients in muscle groups known to undergo atrophy vs muscle groups that do not undergo atrophy
    M Moukas
    F Takis
    K Mandragos
    E Palli
    I Dimitrakaki
    E Panou
    M Vassiliou
    Critical Care, 5 (Suppl 1):
  • [48] Ultrasound Assessment of Adductor Muscle Size Using Muscle Thickness of the Thigh
    Ogawa, Madoka
    Mitsukawa, Naotoshi
    Bemben, Michael G.
    Abe, Takashi
    JOURNAL OF SPORT REHABILITATION, 2012, 21 (03) : 244 - 248
  • [49] Effect of packaging thickness and muscle type on ultrasound-assisted beef quality
    Contreras-Lopez, German
    Morales-Rodriguez, Simon
    Alarcon-Rojo, AlmaD.
    Carrillo-Lopez, Luis M.
    ULTRASONICS SONOCHEMISTRY, 2024, 103
  • [50] A-mode and B-mode Ultrasound Measurement of Subcutaneous Fat Thickness: A Cadaver Analysis Validation Study
    Wagner, Dale R.
    Thompson, Brennan J.
    Anderson, D. Andy
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 257 - 257