CT-Guided Lumbar Nerve Root Injections: Are We Using the Correct Radiation Dose Settings?

被引:14
|
作者
Schauberger, J. S. [1 ]
Kranz, P. G. [1 ]
Choudhury, K. R. [1 ]
Eastwood, J. D. [1 ]
Gray, L. [1 ]
Hoang, J. K. [1 ,2 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
关键词
IMAGE QUALITY; FLUOROSCOPY; EXPOSURE;
D O I
10.3174/ajnr.A3096
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Selecting a lower tube current for CT fluoroscopic spine injections is a method of radiation dose reduction. Ideally tube current should be tailored to the patient's body habitus, but a greater influence on tube current may be the proceduralist's personal preference. The purpose of this study was to compare tube current and fluoroscopy time of different proceduralists for lumbar spine CT-guided selective nerve root blocks, and to correlate image quality to patient diameter and tube current. MATERIALS AND METHODS: Eighty CT-guided SNRBs performed by 4 proceduralists were retrospectively reviewed for tube current and fluoroscopy time. Patient body habitus was evaluated by measuring anteroposterior diameters on scout images. Image quality was evaluated objectively and subjectively: noise was measured in the psoas muscle and images were graded on a 3-point scale. RESULTS: The mean tube current was 59 +/- 20 mA and mean fluoroscopy time was 10.4 +/- 7.5 seconds. The mean tube current between proceduralists differed by almost 2-fold, and there was greater than 2-fold difference in mean fluoroscopy time (P < .0001 and .01, respectively). Mean AP body size was 27 +/- 5 cm. When categoric data of tube current and AP diameter were analyzed, only AP diameter was a statistically significant variable influencing image noise (P = .009). Twenty of 23 patients with AP diameter <= 30 cm had adequate to excellent image quality, even with lower tube current of <= 40 mA. CONCLUSIONS: Wide variability in tube current selection between proceduralists calls for a more objective method of selecting tube current to minimize radiation dose. Body size, measured by AP diameter, had the greatest influence on image quality. This could be used to identify patients for lower tube current selection.
引用
收藏
页码:1855 / 1859
页数:5
相关论文
共 50 条
  • [41] Selective lumbar nerve root blocks with CT fluoroscopic guidance: Technique, results, procedure time, and radiation dose
    Wagner, AL
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2004, 25 (09) : 1592 - 1594
  • [42] Preoperative CT-guided localization of pulmonary nodules with low-dose radiation
    Ma, Yanhe
    Cheng, Shizhao
    Li, Jianhui
    Yuan, Wei
    Song, Zhenchun
    Zhang, Hong
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (07) : 4295 - 4304
  • [43] Clinical Study on CT-guided Modified Akupotomye in the Treatment of Lumbar Nerve Posterior Branch Compression
    乔晋琳
    李金牛
    林井副
    汲广成
    向东东
    沈红星
    WorldJournalofIntegratedTraditionalandWesternMedicine, 2020, 6 (01) : 26 - 31
  • [44] CT-guided vs. fluoroscopically guided transforaminal epidural steroid injections for lumbar radiculopathy: a comparison of efficacy, safety and cost
    Kamp, Jozef P. M.
    Bartlett, Jonathan
    Fahmy, Amr
    To, Kendrick
    Hossain, Rumana
    Akula, Maheswara
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (05) : 2355 - 2361
  • [45] CT-guided vs. fluoroscopically guided transforaminal epidural steroid injections for lumbar radiculopathy: a comparison of efficacy, safety and cost
    Jozef P. M. Kamp
    Jonathan Bartlett
    Amr Fahmy
    Kendrick To
    Rumana Hossain
    Maheswara Akula
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 2355 - 2361
  • [46] Effect of steroid dose on efficacy of CT-guided pudendal nerve blocks for pudendal neuralgia
    Gubbels, Ashley
    Linder, Mitchell
    Baran, Timothy M.
    Koritysskiy, Filip
    Rahman, Akm
    JOURNAL OF ENDOMETRIOSIS AND PELVIC PAIN DISORDERS, 2022, 14 (04) : 192 - 198
  • [47] Ultra-low radiation dose protocol for CT-guided intrathecal nusinersen injections for patients with spinal muscular atrophy and severe scoliosis
    Rosiak, Grzegorz
    Lusakowska, Anna
    Milczarek, Krzysztof
    Konecki, Dariusz
    Fraczek, Anna
    Rowinski, Olgierd
    Kostera-Pruszczyk, Anna
    NEURORADIOLOGY, 2021, 63 (04) : 539 - 545
  • [48] Ultra-low radiation dose protocol for CT-guided intrathecal nusinersen injections for patients with spinal muscular atrophy and severe scoliosis
    Grzegorz Rosiak
    Anna Lusakowska
    Krzysztof Milczarek
    Dariusz Konecki
    Anna Fraczek
    Olgierd Rowinski
    Anna Kostera-Pruszczyk
    Neuroradiology, 2021, 63 : 539 - 545
  • [49] CT-Guided Transforaminal Epidural Injections with Local Anesthetic, Steroid, and Tramadol for the Treatment of Persistent Lumbar Radicular Pain
    Wewalka, Mathias
    Abdelrahimsai, Ahmadollah
    Wiesinger, Guenther F.
    Maria, Eva
    PAIN PHYSICIAN, 2012, 15 (02) : 153 - 159
  • [50] Symptomatic lumbar facet joint cysts treated by CT-guided intracystic and intra-articular steroid injections
    Nicolas Amoretti
    Laurent Huwart
    Pauline Foti
    Pascal Boileau
    Marie-Eve Amoretti
    Amelie Pellegrin
    Pierre-Yves Marcy
    Olivier Hauger
    European Radiology, 2012, 22 : 2836 - 2840