CT-Guided Lumbar Nerve Root Injections: Are We Using the Correct Radiation Dose Settings?

被引:14
|
作者
Schauberger, J. S. [1 ]
Kranz, P. G. [1 ]
Choudhury, K. R. [1 ]
Eastwood, J. D. [1 ]
Gray, L. [1 ]
Hoang, J. K. [1 ,2 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
关键词
IMAGE QUALITY; FLUOROSCOPY; EXPOSURE;
D O I
10.3174/ajnr.A3096
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Selecting a lower tube current for CT fluoroscopic spine injections is a method of radiation dose reduction. Ideally tube current should be tailored to the patient's body habitus, but a greater influence on tube current may be the proceduralist's personal preference. The purpose of this study was to compare tube current and fluoroscopy time of different proceduralists for lumbar spine CT-guided selective nerve root blocks, and to correlate image quality to patient diameter and tube current. MATERIALS AND METHODS: Eighty CT-guided SNRBs performed by 4 proceduralists were retrospectively reviewed for tube current and fluoroscopy time. Patient body habitus was evaluated by measuring anteroposterior diameters on scout images. Image quality was evaluated objectively and subjectively: noise was measured in the psoas muscle and images were graded on a 3-point scale. RESULTS: The mean tube current was 59 +/- 20 mA and mean fluoroscopy time was 10.4 +/- 7.5 seconds. The mean tube current between proceduralists differed by almost 2-fold, and there was greater than 2-fold difference in mean fluoroscopy time (P < .0001 and .01, respectively). Mean AP body size was 27 +/- 5 cm. When categoric data of tube current and AP diameter were analyzed, only AP diameter was a statistically significant variable influencing image noise (P = .009). Twenty of 23 patients with AP diameter <= 30 cm had adequate to excellent image quality, even with lower tube current of <= 40 mA. CONCLUSIONS: Wide variability in tube current selection between proceduralists calls for a more objective method of selecting tube current to minimize radiation dose. Body size, measured by AP diameter, had the greatest influence on image quality. This could be used to identify patients for lower tube current selection.
引用
收藏
页码:1855 / 1859
页数:5
相关论文
共 50 条
  • [21] CT-Guided intervention with low radiation dose: Feasibility and experience
    Lucey, Brian C.
    Varghese, Jose C.
    Hochberg, Aaron
    Blake, Michael A.
    Soto, Jorge A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05) : 1187 - 1194
  • [22] Radiation dose reduction in CT-guided cryoablation of renal tumors
    Zhong, Jim
    Gallagher, Michael
    Hounslow, Chris
    Iball, Gareth
    Wah, Tze
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2021, 27 (02) : 244 - 248
  • [23] Radiation dose reduction in pediatric CT-guided musculoskeletal procedures
    Anand S. Patel
    Bruno Soares
    Jesse Courtier
    John D. MacKenzie
    Pediatric Radiology, 2013, 43 : 1303 - 1308
  • [24] Radiation Dose in CT-guided Interventional Procedures: Establishing a Benchmark
    Leng, Shuai
    RADIOLOGY, 2018, 289 (01) : 158 - 159
  • [25] Radiation Dose Reduction for CT-guided Renal Tumor Cryoablation
    Leng, S.
    Atwell, T.
    Yu, L.
    Mandrekar, J.
    Liewis, B.
    Woodrum, D.
    Bruesewitz, M.
    McCollough, C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [26] Imaging dose management using multi-resolution in CT-guided radiation therapy
    Sheng, K
    Jeraj, R
    Shaw, R
    Mackie, TR
    Paliwal, BR
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (06): : 1205 - 1219
  • [27] Radiation dose of fluoroscopy-guided versus ultralow-dose CT-fluoroscopy-guided lumbar spine epidural steroid injections
    Wieschhoff, Ged G.
    Miskin, Nityanand P.
    Kim, Jeom Soon
    Hamberg, Leena M.
    Mandell, Jacob C.
    SKELETAL RADIOLOGY, 2022, 51 (05) : 1055 - 1062
  • [28] Radiation dose of fluoroscopy-guided versus ultralow-dose CT-fluoroscopy-guided lumbar spine epidural steroid injections
    Ged G. Wieschhoff
    Nityanand P. Miskin
    Jeom Soon Kim
    Leena M. Hamberg
    Jacob C. Mandell
    Skeletal Radiology, 2022, 51 : 1055 - 1062
  • [29] MRI-Guided and CT-Guided Cervical Nerve Root Infiltration Therapy: A Cost Comparison
    Maurer, M. H.
    Froeling, V.
    Roettgen, R.
    Bretschneider, T.
    Hartwig, T.
    Disch, A. C.
    de Bucourt, M.
    Hamm, B.
    Streitparth, F.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (06): : 559 - 566
  • [30] Is There a Need for Contrast Administration Prior to CT-Guided Cervical Nerve Root Block?
    Ryan, T. M.
    Kavanagh, E. C.
    MacMahon, P. J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (04) : E45 - E45