Results from an amino acid racemization inter-laboratory proficiency study; design and performance evaluation

被引:17
|
作者
Powell, Joanne [1 ]
Collins, Matthew J. [1 ]
Cussens, James [3 ]
MacLeod, Norman [4 ]
Penkman, Kirsty E. H. [2 ]
机构
[1] Univ York, Dept Archaeol, BioArCh, York YO10 5DD, N Yorkshire, England
[2] Univ York, Dept Chem, BioArCh, York YO10 5DD, N Yorkshire, England
[3] Univ York, Dept Comp Sci, YCCSA, York YO10 5DD, N Yorkshire, England
[4] Nat Hist Museum, Dept Palaeontol, London SW7 5BD, England
基金
英国艺术与人文研究理事会;
关键词
Amino acid racemization; Geochronology; Inter-laboratory comparison; Proficiency test; Accuracy; Precision; Bias; Measurement uncertainty;
D O I
10.1016/j.quageo.2012.11.001
中图分类号
P9 [自然地理学];
学科分类号
0705 ; 070501 ;
摘要
It is nearly thirty years since the last inter-laboratory study was carried out for amino acid racemization (AAR) analysis using powdered fossil material (Wehmiller 1984). Since then there have been major changes in sample preparation and instrumentation, and it was considered timely to coordinate a new inter-laboratory study in support of current methodologies. In 2010, two such studies were undertaken. The first of these, coordinated by Wehmiller (this edition), used homogeneous hydrolysates of Pleistocene mollusc and eggshell materials and focused on the agreement of analytical measurements between laboratories, without interference from differing sample preparation procedures. The second (this study) was designed specifically as a proficiency test. Unlike previous inter-laboratory comparisons that have focussed on precision estimates, the purpose of this study was to carry out an evaluation of measurement bias by comparing the measurement results of laboratories carrying out their routine methods, including extraction, against the consensus values. Participants were sent one dried sample of a mixed amino acid standards solution and five homogeneous powders: two Pleistocene mollusc test materials prepared from material (ILC-A) supplied and used by Wehmiller in previous inter-laboratory studies (1984; and this edition), one Pleistocene opercula test material from the terrestrial gastropod, Bithynia tentaculata, and two heat-treated modern ostrich eggshell test materials. Results from this study demonstrate that whilst individual laboratory precision may be excellent, suggesting good control of random error influences (less than 1% for replicate measurements by some individual laboratories), agreement between methods, or even between laboratories carrying out the same method, may be very different. Trueness evaluation (determined as the relative percentage bias) reveals the extent of the disagreement reflected by the interlaboratory variability. Individual laboratory D/L value biases of 10-30% or more when compared to the consensus values are not uncommon. We demonstrate why bias contributions should also be included in AAR uncertainty estimation and recommend that the preparation of defined reference materials are seen as a priority in order to control and correct for systematic error influences in the analytical system. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:183 / 197
页数:15
相关论文
共 50 条
  • [31] Inter-laboratory proficiency testing scheme for tumour next-generation sequencing in Ontario: a pilot study
    Spence, T.
    Stickle, N.
    Yu, C.
    Chow, H.
    Feilotter, H.
    Lo, B.
    McCready, E.
    Sadikovic, B.
    Siu, L. L.
    Bedard, P. L.
    Stockley, T. L.
    CURRENT ONCOLOGY, 2019, 26 (06) : E717 - E732
  • [32] Evaluation of mouse bioassay results in an inter-laboratory comparison for paralytic shellfish poisoning toxins
    曹际娟
    郑江
    于兵
    王秋艳
    徐君怡
    李爱峰
    ChineseJournalofOceanologyandLimnology, 2011, 29 (04) : 912 - 916
  • [33] Evaluation of mouse bioassay results in an inter-laboratory comparison for paralytic shellfish poisoning toxins
    曹际娟
    郑江
    于兵
    王秋艳
    徐君怡
    李爱峰
    Journal of Oceanology and Limnology, 2011, (04) : 912 - 916
  • [34] Evaluation of mouse bioassay results in an inter-laboratory comparison for paralytic shellfish poisoning toxins
    Cao Jijuan
    Zheng Jiang
    Yu Bing
    Wang Qiuyan
    Xu Junyi
    Li Aifeng
    CHINESE JOURNAL OF OCEANOLOGY AND LIMNOLOGY, 2011, 29 (04): : 912 - 916
  • [35] Evaluation of mouse bioassay results in an inter-laboratory comparison for paralytic shellfish poisoning toxins
    Jijuan Cao
    Jiang Zheng
    Bing Yu
    Qiuyan Wang
    Junyi Xu
    Aifeng Li
    Chinese Journal of Oceanology and Limnology, 2011, 29 : 912 - 916
  • [36] Inter-laboratory consistency and variability in the buccal micronucleus cytome assay depends on biomarker scored and laboratory experience: results from the HUMNxl international inter-laboratory scoring exercise
    Bolognesi, Claudia
    Knasmueller, Siegfried
    Nersesyan, Armen
    Roggieri, Paola
    Ceppi, Marcello
    Bruzzone, Marco
    Blaszczyk, Ewa
    Mielzynska-Svach, Danuta
    Milic, Mirta
    Bonassi, Stefano
    Benedetti, Danieli
    Da Silva, Juliana
    Toledo, Raphael
    Favero Salvadori, Daisy Maria
    Groot de Restrepo, Helena
    Filipic, Metka
    Hercog, Klara
    Aktas, Ayca
    Burgaz, Sema
    Kundi, Michael
    Grummt, Tamara
    Thomas, Philip
    Hor, Maryam
    Escudero-Fung, Maria
    Holland, Nina
    Fenech, Michael
    MUTAGENESIS, 2017, 32 (02) : 257 - 266
  • [37] Inter-laboratory variation in results from immunohistochemical assessment of estrogen receptor status
    Layfield, LJ
    Goldstein, N
    Proia, A
    MODERN PATHOLOGY, 2002, 15 (01) : 40A - 41A
  • [38] Inter-laboratory variation in results from immunohistochemical assessment of estrogen receptor status
    Layfield, LJ
    Goldstein, N
    Proia, A
    LABORATORY INVESTIGATION, 2002, 82 (01) : 40A - 41A
  • [39] Assessment of Inter-Laboratory Variability for Flow Cytometric Crossmatch Testing: Lessons Learned from Proficiency Surveys
    Philogene, Mary Carmelle
    Timofeeva, Olga A.
    Gimferrer, Idoia
    Hod-Dvorai, Reut
    HUMAN IMMUNOLOGY, 2025, 85 (01)
  • [40] The choice of clinical laboratory may change study outcome: An inter-laboratory evaluation of aminotransferase measures
    Green, Jody L.
    Campagna, Elizabeth
    Bogdan, Gregory M.
    Heard, Kennon
    Dart, Richard C.
    HEPATOLOGY, 2007, 46 (04) : 808A - 809A