Analysis of Ag(I) Biocide in Water Samples Using Anodic Stripping Voltammetry with a Boron-Doped Diamond Disk Electrode

被引:27
|
作者
Maldonado, Vanessa Y. [1 ,5 ]
Espinoza-Montero, Patricio J. [2 ,3 ]
Rusinek, Cory A. [4 ]
Swain, Greg M. [5 ]
机构
[1] Escuela Politec Nacl, Fac Ingn Quim & Agroind, Ladron Guevara E11-253,POB 17-01-2759, Quito 170525, Ecuador
[2] Pontificia Univ Catolica Ecuador, Escuela Ciencias Quim, Ave 12 Octubre & Roca,POB 17-01-2184, Quito, Ecuador
[3] Escuela Politec Nacl, Dept Ingn Civil & Ambiental, Ladron Guevara E11-253,POB 17-01-2759, Quito, Ecuador
[4] Michigan State Univ, Fraunhofer Ctr Coatings & Diamond Technol, E Lansing, MI 48824 USA
[5] Michigan State Univ, Dept Chem, E Lansing, MI 48824 USA
关键词
CARBON-PASTE ELECTRODE; SOLID-PHASE EXTRACTION; THIN-FILM ELECTRODES; HEAVY-METAL IONS; HYDROGENATED GLASSY-CARBON; SILVER NANOPARTICLES; ELECTROCHEMICAL DETECTION; PYROLYTIC-GRAPHITE; IN-SITU; TOXICITY;
D O I
10.1021/acs.analchem.7b04983
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electroanalytical performance of a new commercial boron doped diamond disk and a traditional nanocrystalline thin-film electrode were compared for the anodic stripping voltammetric determination of Ag(I). The diamond disk electrode is more flexible than the planar film as the former is compatible with most electrochemical cell designs including those incorporating magnetic stirring. Additionally, mechanical polishing and surface cleaning are simpler to execute. Differential pulse anodic stripping voltammetry (DPASV) was used to detect Ag(I) in standard solutions after optimization of the deposition potential, deposition time and scan rate. The optimized conditions were used to determine the concentration of Ag(I) in a NASA simulated potable water sample and a NIST standard reference solution. The electrochemical results were validated by ICP-OES measurements of the same solutions. The detection figures of merit for the disk electrode were as good or superior to those for the thin-film electrode. Detection limits were <= 5 mu g L-1 (S/N = 3) for a 120 s deposition period, and response variabilities were <5% RSD. The polished disk electrode presented a more limited linear dynamic range presumably because of the reduced surface area available for metal phase formation. The concentrations of Ag(I) in the two water samples, as determined by DPASV, were in good agreement with the concentrations determined by ICP-OES.
引用
收藏
页码:6477 / 6485
页数:9
相关论文
共 50 条
  • [31] Anodic behaviour of fulvestrant and its voltammetric determination in pharmaceuticals and human serum on highly boron-doped diamond electrode using differential pulse adsorptive stripping voltammetry
    Dogan-Topal, B.
    Kul, Dilek
    Ozkan, Sibel A.
    Uslu, B.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2011, 41 (11) : 1253 - 1260
  • [32] Anodic behaviour of fulvestrant and its voltammetric determination in pharmaceuticals and human serum on highly boron-doped diamond electrode using differential pulse adsorptive stripping voltammetry
    B. Dogan-Topal
    Dilek Kul
    Sibel A. Ozkan
    B. Uslu
    Journal of Applied Electrochemistry, 2011, 41 : 1253 - 1260
  • [33] Electrochemical determination of pterostilbene at a cathodically pretreated boron-doped diamond electrode using square-wave adsorptive anodic stripping voltammetry in cationic surfactant media
    Yigit, Aydin
    Yardim, Yavuz
    Zorer, Ozlem Selcuk
    Senturk, Zuhre
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 231 : 688 - 695
  • [34] The Use of Boron-Doped Diamond Electrode for the Determination of Selected Biocides in Water Samples
    Mielech-Lukasiewicz, Katarzyna
    Starczewska, Barbara
    WATER, 2019, 11 (08)
  • [35] Determination of methiocarb pesticide using differential pulse voltammetry with a boron-doped diamond electrode
    Chylkova, J.
    Tomaskova, M.
    Svancara, I.
    Janikova, L.
    Selesovska, R.
    ANALYTICAL METHODS, 2015, 7 (11) : 4671 - 4677
  • [36] Determination of viloxazine by differential pulse voltammetry with boron-doped diamond electrode
    Madej, Maria
    Kochana, Jolanta
    Bas, Boguslaw
    MONATSHEFTE FUR CHEMIE, 2019, 150 (09): : 1655 - 1665
  • [37] Determination of viloxazine by differential pulse voltammetry with boron-doped diamond electrode
    Maria Madej
    Jolanta Kochana
    Bogusław Baś
    Monatshefte für Chemie - Chemical Monthly, 2019, 150 : 1655 - 1665
  • [38] Determination of manganese in particulate matter of workplace environments using a boron-doped diamond electrode and cathodic stripping square wave voltammetry
    Felix, Fabiana da Silva
    Mendes de Barros, Rita de Cassia
    Lichtig, Jaim
    Masini, Jorge C.
    Ferreira, Neidenei Gomes
    QUIMICA NOVA, 2005, 28 (06): : 1000 - 1005
  • [39] Interaction of Pb and Cd during anodic stripping voltammetric analysis at boron-doped diamond electrodes
    Manivannan, A
    Kawasaki, R
    Tryk, DA
    Fujishima, A
    ELECTROCHIMICA ACTA, 2004, 49 (20) : 3313 - 3318
  • [40] Electrochemical sensing of thiabendazole in complex samples using boron-doped diamond electrode
    Paulino Ribeiro, Francisco Wirley
    de Oliveira, Raissa Costa
    de Oliveira, Andre Gadelha
    Nascimento, Ronaldo Ferreira
    Becker, Helena
    de Lima-Neto, Pedro
    Correia, Adriana Nunes
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 866