Analysis of Ag(I) Biocide in Water Samples Using Anodic Stripping Voltammetry with a Boron-Doped Diamond Disk Electrode

被引:27
|
作者
Maldonado, Vanessa Y. [1 ,5 ]
Espinoza-Montero, Patricio J. [2 ,3 ]
Rusinek, Cory A. [4 ]
Swain, Greg M. [5 ]
机构
[1] Escuela Politec Nacl, Fac Ingn Quim & Agroind, Ladron Guevara E11-253,POB 17-01-2759, Quito 170525, Ecuador
[2] Pontificia Univ Catolica Ecuador, Escuela Ciencias Quim, Ave 12 Octubre & Roca,POB 17-01-2184, Quito, Ecuador
[3] Escuela Politec Nacl, Dept Ingn Civil & Ambiental, Ladron Guevara E11-253,POB 17-01-2759, Quito, Ecuador
[4] Michigan State Univ, Fraunhofer Ctr Coatings & Diamond Technol, E Lansing, MI 48824 USA
[5] Michigan State Univ, Dept Chem, E Lansing, MI 48824 USA
关键词
CARBON-PASTE ELECTRODE; SOLID-PHASE EXTRACTION; THIN-FILM ELECTRODES; HEAVY-METAL IONS; HYDROGENATED GLASSY-CARBON; SILVER NANOPARTICLES; ELECTROCHEMICAL DETECTION; PYROLYTIC-GRAPHITE; IN-SITU; TOXICITY;
D O I
10.1021/acs.analchem.7b04983
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electroanalytical performance of a new commercial boron doped diamond disk and a traditional nanocrystalline thin-film electrode were compared for the anodic stripping voltammetric determination of Ag(I). The diamond disk electrode is more flexible than the planar film as the former is compatible with most electrochemical cell designs including those incorporating magnetic stirring. Additionally, mechanical polishing and surface cleaning are simpler to execute. Differential pulse anodic stripping voltammetry (DPASV) was used to detect Ag(I) in standard solutions after optimization of the deposition potential, deposition time and scan rate. The optimized conditions were used to determine the concentration of Ag(I) in a NASA simulated potable water sample and a NIST standard reference solution. The electrochemical results were validated by ICP-OES measurements of the same solutions. The detection figures of merit for the disk electrode were as good or superior to those for the thin-film electrode. Detection limits were <= 5 mu g L-1 (S/N = 3) for a 120 s deposition period, and response variabilities were <5% RSD. The polished disk electrode presented a more limited linear dynamic range presumably because of the reduced surface area available for metal phase formation. The concentrations of Ag(I) in the two water samples, as determined by DPASV, were in good agreement with the concentrations determined by ICP-OES.
引用
收藏
页码:6477 / 6485
页数:9
相关论文
共 50 条
  • [21] Detection of trace lead at boron-doped diamond electrodes by anodic stripping analysis
    Manivannan, A
    Tryk, DA
    Fujishima, A
    ELECTROCHEMICAL AND SOLID STATE LETTERS, 1999, 2 (09) : 455 - 456
  • [22] Anodic Stripping Voltammetry of Se4+ on Gold-Modified Boron-Doped Diamond Electrodes
    Fierro, Stephane
    Watanabe, Takeshi
    Akai, Kazumi
    Yamanuki, Mikito
    Einaga, Yasuaki
    INTERNATIONAL JOURNAL OF ELECTROCHEMISTRY, 2012, 2012
  • [23] Detection of aniline at boron-doped diamond electrodes with cathodic stripping voltammetry
    Spataru, Tanja
    Spataru, Nicolae
    Fujishima, Akira
    TALANTA, 2007, 73 (02) : 404 - 406
  • [24] Abrasive stripping voltammetry of silver and tin at boron-doped diamond electrodes
    Chatterjee, A
    Wiltshire, R
    Holt, KB
    Compton, RG
    Foord, JS
    Marken, F
    DIAMOND AND RELATED MATERIALS, 2002, 11 (3-6) : 646 - 650
  • [25] Metal ion analysis in contaminated water samples using anodic stripping voltammetry and a nanocrystalline diamond thin-film electrode
    Sonthalia, P
    McGaw, E
    Show, Y
    Swain, GM
    ANALYTICA CHIMICA ACTA, 2004, 522 (01) : 35 - 44
  • [26] Sensitive Detection of Capsaicin by Adsorptive Stripping Voltammetry at a Boron-Doped Diamond Electrode in the Presence of Sodium Dodecylsulfate
    Yardim, Yavuz
    ELECTROANALYSIS, 2011, 23 (10) : 2491 - 2497
  • [27] Imunossupressor leflunomide anodic behaviour at a boron-doped diamond electrode
    Suoro, Rafael M.
    Enache, Teodor A.
    Serrano, Silvia H. P.
    Oliveira-Brett, Ana Maria
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 729 : 61 - 67
  • [28] Controlling the diffusion profile of electroactive species for selective anodic stripping voltammetry of cadmium at boron-doped diamond electrodes
    Sugitani, Ai
    Watanabe, Takeshi
    Ivandini, Tribidasari A.
    Iguchi, Tatsuo
    Einaga, Yasuaki
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2013, 15 (01) : 142 - 147
  • [29] Anodic stripping voltammetry of gold nanoparticles at boron-doped diamond electrodes and its application in immunochromatographic strip tests
    Ivandini, Tribidasari A.
    Wicaksono, Wiyogo P.
    Saepudin, Endang
    Rismetov, Bakhadir
    Einaga, Yasuaki
    TALANTA, 2015, 134 : 136 - 143
  • [30] Simultaneous Determination of Paracetamol and Ibuprofen in Pharmaceutical Samples by Differential Pulse Voltammetry Using a Boron-Doped Diamond Electrode
    Lima, Amanda B.
    Torres, Livia M. F. C.
    Guimaraes, Carlos F. R. C.
    Verly, Rodrigo M.
    da Silva, Leonardo M.
    Carvalho Junior, Alvaro D.
    dos Santos, Wallans T. P.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2014, 25 (03) : 478 - 483