Influence of dentin biomodification with epigallocatechin-3-gallate on the bond strength of self-etch adhesive: Twelve-month results

被引:20
|
作者
Neri, Jiovanne R. [1 ,2 ,3 ]
Yamauti, Monica [4 ]
da Silveira, Felipe D. [1 ]
Mendonca, Juliano S. [1 ]
de Carvalho, Ricardo M. [5 ]
Santiago, Sergio L. [1 ]
机构
[1] Univ Fed Ceara, Fac Pharm Dent & Nursing, Dept Restorat Dent, Fortaleza, Ceara, Brazil
[2] Univ Fortaleza, Grad Sch Dent, Fortaleza, Ceara, Brazil
[3] Univ Ctr Christus, Grad Sch Dent, Fortaleza, Ceara, Brazil
[4] Univ Fed Minas Gerais, Fac Dent, Dept Restorat Dent, Belo Horizonte, MG, Brazil
[5] Univ British Columbia, Fac Dent, Dept Oral Biol & Med Sci, Vancouver, BC, Canada
关键词
Self-etch adhesive; Dentine; MMP inhibitors; Micro-tensile; CARIES-AFFECTED DENTIN; COLLAGEN DEGRADATION; MATRIX METALLOPROTEINASES; INTRAPULPAL PRESSURE; ARTIFICIAL SALIVA; BIOFILM FORMATION; CHLORHEXIDINE; DURABILITY; RESIN; EGCG;
D O I
10.1016/j.ijadhadh.2016.08.007
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
To evaluate the effectiveness of dentin biomodification with epigallocatechin-3-gallate (EGCG) on the resin-dentin bonds over time. Twenty seven extracted human third molars were prepared to expose a flat dentin surface and divided into 3 groups (n=9). Dentin surfaces were dried and treated with 20 mu L aliquots of either distilled water (control); 2% chlorhexidine digluconate solution (CHX) or 0.1% EGCG aqueous solution. Solutions were rubbed for 60 s followed by bonding with Adper Easy One, and 5-mm-thick resin crown build-up. Bonded teeth were stored in distilled water for 24 h and then longitudinally sectioned to obtain bonded sticks. One-third of the specimens were immediately subjected to a micro tensile bond strength test in tension at 0.5 mm/min, while the remaining specimens were tested after six and twelve months of storage in distilled water at 37 degrees C. Data were analyzed with Two-way ANOVA and Holm-Sidak method. After 24 h of storage, mean bond strength values were not significantly different among all groups (p > 0.05). Bond strengths of EGCG and CHX remained stable after 6 and 12 months. (p > 0.05). To conclude, pretreatment with EGCG or CHX preserved the bonding of Adper Easy One to dentin after six and twelve months of storage. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:81 / 86
页数:6
相关论文
共 50 条
  • [31] The effect of 6-month water storage on the bond strength of self-etch adhesives bonded to dentin
    Zander-Grande, Christiana
    Loguercio, Alessandro D.
    Stanislawczuk, Rodrigo
    Martins, Gislaine Cristine
    Mongruel Gomes, Osnara Maria
    Reis, Alessandra
    AMERICAN JOURNAL OF DENTISTRY, 2011, 24 (04): : 239 - 244
  • [32] Effect of chlorhexidine on the shear bond strength of self-etch adhesives to dentin
    Chaharom, Mohammad Esmaeel Ebrahimi
    Ajami, Amir Ahmad
    Kimyai, Soodabeh
    Abbasi, Ahmad
    AFRICAN JOURNAL OF BIOTECHNOLOGY, 2011, 10 (49): : 10054 - 10057
  • [33] Effect of Bur Roughness on Bond to Sclerotic Dentin With Self-etch Adhesive Systems
    Luque-Martinez, I. V.
    Mena-Serrano, A.
    Munoz, M. A.
    Hass, V.
    Reis, A.
    Loguercio, A. D.
    OPERATIVE DENTISTRY, 2013, 38 (01) : 39 - 47
  • [34] Influence of different Er,Cr:YSGG laser parameters on long-term dentin bond strength of self-etch adhesive
    Yildirim, Tahsin
    Ayar, Muhammet Kerim
    Yesilyurt, Cemal
    LASERS IN MEDICAL SCIENCE, 2015, 30 (09) : 2363 - 2368
  • [35] Epigallocatechin-3-gallate increased the push out bond strength of an epoxy resin sealer to root dentin
    Pheenithicharoenkul, Suthida
    Panichuttra, Anchana
    DENTAL MATERIALS JOURNAL, 2016, 35 (06) : 888 - 892
  • [36] Influence of different Er,Cr:YSGG laser parameters on long-term dentin bond strength of self-etch adhesive
    Tahsin Yildirim
    Muhammet Kerim Ayar
    Cemal Yesilyurt
    Lasers in Medical Science, 2015, 30 : 2363 - 2368
  • [37] Human dentin bond strength of chlorhexidine containing universal adhesive system used in total-etch and self-etch modes
    Tessore, Romina
    Silveira, Camila
    Vazquez, Priscila
    Mederos, Matias
    Garcia, Andres
    Cuevas-Suarez, Carlos Enrique
    Grazioli, Guillermo
    ODONTOESTOMATOLOGIA, 2020, 22 (35): : 20 - 29
  • [38] Influence of thermal cycling on dentin bond strengths of single-step self-etch adhesive systems
    Asaka, Y.
    Amano, S.
    Rikuta, A.
    Kurokawa, H.
    Miyazaki, M.
    Platt, J. A.
    Moore, B. K.
    OPERATIVE DENTISTRY, 2007, 32 (01) : 73 - 78
  • [39] Effect of sonic application mode on the resin-dentin bond strength and nanoleakage of simplified self-etch adhesive
    Mena-Serrano, Alexandra
    Garcia, Eugenio Jose
    Loguercio, Alessandro Dourado
    Reis, Alessandra
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (03) : 729 - 736
  • [40] Influence of Adhesive Application Time on Enamel Bond Strength of Single-step Self-etch Adhesive Systems
    Tsuchiya, H.
    Tsubota, K.
    Iwasa, M.
    Ando, S.
    Miyazaki, M.
    Platt, J. A.
    OPERATIVE DENTISTRY, 2010, 35 (01) : 77 - 83