Influence of dentin biomodification with epigallocatechin-3-gallate on the bond strength of self-etch adhesive: Twelve-month results

被引:20
|
作者
Neri, Jiovanne R. [1 ,2 ,3 ]
Yamauti, Monica [4 ]
da Silveira, Felipe D. [1 ]
Mendonca, Juliano S. [1 ]
de Carvalho, Ricardo M. [5 ]
Santiago, Sergio L. [1 ]
机构
[1] Univ Fed Ceara, Fac Pharm Dent & Nursing, Dept Restorat Dent, Fortaleza, Ceara, Brazil
[2] Univ Fortaleza, Grad Sch Dent, Fortaleza, Ceara, Brazil
[3] Univ Ctr Christus, Grad Sch Dent, Fortaleza, Ceara, Brazil
[4] Univ Fed Minas Gerais, Fac Dent, Dept Restorat Dent, Belo Horizonte, MG, Brazil
[5] Univ British Columbia, Fac Dent, Dept Oral Biol & Med Sci, Vancouver, BC, Canada
关键词
Self-etch adhesive; Dentine; MMP inhibitors; Micro-tensile; CARIES-AFFECTED DENTIN; COLLAGEN DEGRADATION; MATRIX METALLOPROTEINASES; INTRAPULPAL PRESSURE; ARTIFICIAL SALIVA; BIOFILM FORMATION; CHLORHEXIDINE; DURABILITY; RESIN; EGCG;
D O I
10.1016/j.ijadhadh.2016.08.007
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
To evaluate the effectiveness of dentin biomodification with epigallocatechin-3-gallate (EGCG) on the resin-dentin bonds over time. Twenty seven extracted human third molars were prepared to expose a flat dentin surface and divided into 3 groups (n=9). Dentin surfaces were dried and treated with 20 mu L aliquots of either distilled water (control); 2% chlorhexidine digluconate solution (CHX) or 0.1% EGCG aqueous solution. Solutions were rubbed for 60 s followed by bonding with Adper Easy One, and 5-mm-thick resin crown build-up. Bonded teeth were stored in distilled water for 24 h and then longitudinally sectioned to obtain bonded sticks. One-third of the specimens were immediately subjected to a micro tensile bond strength test in tension at 0.5 mm/min, while the remaining specimens were tested after six and twelve months of storage in distilled water at 37 degrees C. Data were analyzed with Two-way ANOVA and Holm-Sidak method. After 24 h of storage, mean bond strength values were not significantly different among all groups (p > 0.05). Bond strengths of EGCG and CHX remained stable after 6 and 12 months. (p > 0.05). To conclude, pretreatment with EGCG or CHX preserved the bonding of Adper Easy One to dentin after six and twelve months of storage. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:81 / 86
页数:6
相关论文
共 50 条
  • [21] Effect of epigallocatechin-3-gallate and thermal cycling on the bond strength of resin cements to the root dentin
    Messias, Danielle Cristine
    da Silva, Moises Franco Barbosa
    de Faria, Natalia Spadini
    Dias-Arnez, Tatiane Rocco
    Rached-Junior, Fuad Jacob
    Sousa, Ana Beatriz Silva
    ODONTOLOGY, 2021, 109 (04) : 854 - 859
  • [22] Effect of epigallocatechin-3-gallate solutions on bond durability at the adhesive interface in caries-affected dentin
    Nogueira Fialho, Melissa Proenca
    Hass, Viviane
    Nogueira, Rodrigo Proenca
    Gomes Franca, Fabiana Mantovani
    Turssi, Cecilia Pedroso
    Basting, Roberta Tarkany
    Botelho Amaral, Flavia Lucisano
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 91 : 398 - 405
  • [23] Microtensile bond strength of a filled vs unfilled adhesive to dentin using self-etch and total-etch technique
    Say, EC
    Nakajima, M
    Senawongse, P
    Soyman, M
    Özer, F
    Ogata, M
    Tagami, J
    JOURNAL OF DENTISTRY, 2006, 34 (04) : 283 - 291
  • [24] Microshear bond strength and interfacial morphology of etch-and-rinse and self-etch adhesive systems to superficial and deep dentin
    Yousry, Mai Mahmoud
    ElNaga, Albeer Abo
    Hafez, Randa M.
    El-Badrawy, Wafa
    QUINTESSENCE INTERNATIONAL, 2011, 42 (09): : E96 - E106
  • [25] Microtensile bond strength of etch and rinse versus self-etch adhesive systems
    Hamouda, Ibrahim M.
    Samra, Nagia R.
    Badawi, Manal F.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2011, 4 (03) : 461 - 466
  • [26] Self-etch or etch-and-rinse mode did not affect the microshear bond strength of a universal adhesive to primary dentin
    Thanaratikul, Benjaporn
    Santiwong, Busayarat
    Harnirattisai, Choltacha
    DENTAL MATERIALS JOURNAL, 2016, 35 (02) : 174 - 179
  • [27] Effect of Desensitizing Agents on the Microtensile Bond Strength of a Two-step Self-etch Adhesive to Dentin
    Arisu, H. D.
    Dalkihc, E.
    Uctasli, M. B.
    OPERATIVE DENTISTRY, 2011, 36 (02) : 153 - 161
  • [28] Effect of sonic application mode on the resin–dentin bond strength and nanoleakage of simplified self-etch adhesive
    Alexandra Mena-Serrano
    Eugenio Jose Garcia
    Alessandro Dourado Loguercio
    Alessandra Reis
    Clinical Oral Investigations, 2014, 18 : 729 - 736
  • [29] Microtensile Bond Strength of Self-Etch Adhesives on Dentin Treated with Chlorhexidine
    Furtado, Carolina O. D. A.
    Baroudi, Kusai
    Amaral, Marina
    Amorim, Thiago N.
    Devito, Karina L.
    de Goes, Mario F.
    Salvio, Luciana A.
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2024, 32 (01): : 133 - 141
  • [30] Effect of the C-factor and Dentin Preparation Method in the Bond Strength of a Mild Self-etch Adhesive
    Marques, M. S. M.
    Kenshima, S.
    Muench, A.
    Ballester, R. Y.
    Rodrigues Filho, L. E.