Comparison of Diagnostic Accuracy between Octopus 900 and Goldmann Kinetic Visual Fields

被引:21
|
作者
Rowe, Fiona J. [1 ]
Rowlands, Alison [2 ]
机构
[1] Univ Liverpool, Dept Hlth Serv Res, Liverpool L69 3GB, Merseyside, England
[2] Warrington & Halton Hosp NHS Fdn Trust, Dept Ophthalmol, Warrington WA5 1QG, Cheshire, England
关键词
IDIOPATHIC INTRACRANIAL HYPERTENSION; PERIMETRY;
D O I
10.1155/2014/214829
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose. To determine diagnostic accuracy of kinetic visual field assessment by Octopus 900 perimetry compared with Goldmann perimetry. Methods. Prospective cross section evaluation of 40 control subjects with full visual fields and 50 patients with known visual field loss. Comparison of test duration and area measurement of isopters for Octopus 3, 5, and 10 degrees/sec stimulus speeds. Comparison of test duration and type of visual field classification for Octopus versus Goldmann perimetry. Results were independently graded for presence/absence of field defect and for type and location of defect. Statistical evaluation comprised of ANOVA and paired t test for evaluation of parametric data with Bonferroni adjustment. Bland Altman and Kappa tests were used for measurement of agreement between data. Results. Octopus 5 degrees/sec perimetry had comparable test duration to Goldmann perimetry. Octopus perimetry reliably detected type and location of visual field loss with visual fields matched to Goldmann results in 88.8% of results (K = 0.775). Conclusions. Kinetic perimetry requires individual tailoring to ensure accuracy. Octopus perimetry was reproducible for presence/absence of visual field defect. Our screening protocol when using Octopus perimetry is 5 degrees/sec for determining boundaries of peripheral isopters and 3 degrees/sec for blind spot mapping with further evaluation of area of field loss for defect depth and size.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Direct comparison of the diagnostic accuracy between blood and cerebrospinal fluid procalcitonin levels in patients with meningitis
    Shen, Hong-Yuan
    Gao, Wei
    Cheng, Juan-Juan
    Zhao, Shi-Di
    Sun, Yi
    Han, Zhi-Jun
    Hua, Jun
    CLINICAL BIOCHEMISTRY, 2015, 48 (16-17) : 1079 - 1082
  • [42] Diagnostic accuracy of glycoproteins in the assessment of liver fibrosis: A comparison between laminin, fibronectin, and hyaluronic acid
    Younesi, Simin
    Parsian, Hadi
    TURKISH JOURNAL OF GASTROENTEROLOGY, 2019, 30 (06): : 524 - 531
  • [43] Comparison of diagnostic accuracy between brush and basket cytology for differential diagnosis of bile duct stricture
    Kim, Chang Joon
    Kim, Hong Joo
    Park, Dong Il
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2012, 27 : 71 - 71
  • [44] Diagnostic Accuracy of Coronary Computed Tomography Angiography A Comparison Between Prospective and Retrospective Electrocardiogram Triggering
    Pontone, Gianluca
    Andreini, Daniele
    Bartorelli, Antonio L.
    Cortinovis, Sarah
    Mushtaq, Saima
    Bertella, Erika
    Annoni, Andrea
    Formenti, Alberto
    Nobili, Enrica
    Trabattoni, Daniela
    Montorsi, Piero
    Ballerini, Giovanni
    Agostoni, Piergiuseppe
    Pepi, Mauro
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (04) : 346 - 355
  • [45] A COMPARISON OF UNWEIGHTED AND FLUCTUATION-WEIGHTED INDEXES (WITHIN THE CENTRAL 28-DEGREES OF GLAUCOMATOUS VISUAL-FIELDS MEASURED WITH THE OCTOPUS AUTOMATED PERIMETER)
    FUNKHOUSER, AT
    FANKHAUSER, F
    INTERNATIONAL OPHTHALMOLOGY, 1991, 15 (05) : 347 - 351
  • [46] Diagnostic Accuracy of CT Angiography in the Evaluation of Stenosis in Lower Limbs: Comparison Between Visual Score and Quantitative Analysis Using a Semiautomated 3D Software
    Iezzi, Roberto
    Santoro, Marco
    Dattesi, Roberta
    la Torre, Michele Fabio
    Guerra, Alessandra
    Di Stasi, Carmine
    Antonuccio, Enzo Gabriele Maria
    Marano, Riccardo
    Bonomo, Lorenzo
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (03) : 419 - 425
  • [47] Comparison of diagnostic ability between visual and quantitative analysis of salivary gland scintigraphy in Sjogren syndrome
    Yoon, Seok-Ho
    Song, Hee Sung
    Jo, Kyung Sook
    Lee, Su Jin
    Yoon, Joon-Kee
    An, Young-Sil
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [48] Diagnostic Innovations in Glaucoma Study (DIGS): Diagnostic Accuracy of the Spectralis Normative Database in Differentiating between Healthy and Early Visual Field Defect Eyes
    Silverman, Anna
    Sharpsten, Lucie
    Medeiros, Felipe A.
    Khachatryan, Naira
    Hammel, Naama
    Girkin, Christopher A.
    Liebmann, Jeffrey M.
    Weinreb, Robert N.
    Zangwill, Linda M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [49] Diagnostic accuracy in gynecological malignant tumors: A comparison between PET/CT and PET/MRI fusion images
    Nakajo, Kazuya
    Tatsumi, Mituaki
    Inoue, Atsuo
    Isohashi, Kayako
    Higuchi, Ichiro
    Kato, Hiroki
    Shimosegawa, Eku
    Hatazawa, Jun
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [50] Comparison of diagnostic accuracy between three different rules of interpreting high sensitivity troponin T results
    Buccelletti, Francesco
    Galiuto, Leonarda
    Marsiliani, Davide
    Iacomini, Paolo
    Mattogno, Pierpaolo
    Carroccia, Annarita
    Cordischi, Chiara
    Antonini, Simone
    Fedele, Elisa
    Sabbatini, Marta
    Silveri, Nicolo Gentiloni
    Franceschi, Francesco
    INTERNAL AND EMERGENCY MEDICINE, 2012, 7 (04) : 365 - 370