Comparison of Diagnostic Accuracy between Octopus 900 and Goldmann Kinetic Visual Fields

被引:21
|
作者
Rowe, Fiona J. [1 ]
Rowlands, Alison [2 ]
机构
[1] Univ Liverpool, Dept Hlth Serv Res, Liverpool L69 3GB, Merseyside, England
[2] Warrington & Halton Hosp NHS Fdn Trust, Dept Ophthalmol, Warrington WA5 1QG, Cheshire, England
关键词
IDIOPATHIC INTRACRANIAL HYPERTENSION; PERIMETRY;
D O I
10.1155/2014/214829
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose. To determine diagnostic accuracy of kinetic visual field assessment by Octopus 900 perimetry compared with Goldmann perimetry. Methods. Prospective cross section evaluation of 40 control subjects with full visual fields and 50 patients with known visual field loss. Comparison of test duration and area measurement of isopters for Octopus 3, 5, and 10 degrees/sec stimulus speeds. Comparison of test duration and type of visual field classification for Octopus versus Goldmann perimetry. Results were independently graded for presence/absence of field defect and for type and location of defect. Statistical evaluation comprised of ANOVA and paired t test for evaluation of parametric data with Bonferroni adjustment. Bland Altman and Kappa tests were used for measurement of agreement between data. Results. Octopus 5 degrees/sec perimetry had comparable test duration to Goldmann perimetry. Octopus perimetry reliably detected type and location of visual field loss with visual fields matched to Goldmann results in 88.8% of results (K = 0.775). Conclusions. Kinetic perimetry requires individual tailoring to ensure accuracy. Octopus perimetry was reproducible for presence/absence of visual field defect. Our screening protocol when using Octopus perimetry is 5 degrees/sec for determining boundaries of peripheral isopters and 3 degrees/sec for blind spot mapping with further evaluation of area of field loss for defect depth and size.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Comparison between diagnostic accuracy of RIPASA score and Alvarado score in the diagnosis of acute appendicitis
    Ebied, Essam F.
    Mostafa, Mohab G. El Din
    Balamon, Remon M.
    EGYPTIAN JOURNAL OF SURGERY, 2021, 40 (04): : 1110 - 1115
  • [32] THE COMPARISON OF DIAGNOSTIC ACCURACY BETWEEN EULAR/ACR PROVISIONAL CLASSIFICATION FOR PMR AND OTHER CRITERION
    Yokoe, M.
    ANNALS OF THE RHEUMATIC DISEASES, 2014, 73 : 694 - 694
  • [33] Octopus Standard Automated Perimetry, Pulsar Perimetry, Moorfields Motion Displacement Test and Heidelberg Retinal Tomography in Glaucoma Detection - A Comparison of Diagnostic Accuracy
    Oleszczuk, J. D.
    Bergin, C.
    Schnyder, C.
    Crabb, D.
    Sharkawi, E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [34] COMPARISON OF DIAGNOSTIC CONSISTENCY AND DIAGNOSTIC ACCURACY BETWEEN SURVEY RADIOGRAPHY AND COMPUTED TOMOGRAPHY OF THE SKULL IN 30 RABBITS WITH DENTAL DISEASE
    Capello, Vittorio
    Cauduro, Alberto
    JOURNAL OF EXOTIC PET MEDICINE, 2016, 25 (02) : 115 - 127
  • [35] Comparison of global indices and test duration between two visual field analyzers: Octopus 300 and Topcon SBP-3000
    Javier Garcia-Medina, Jose
    Garcia-Medina, Manuel
    Zanon-Moreno, Vicente
    Garcia-Maturana, Carlos
    Javier Cruz-Espinosa, Francisco
    Dolores Pinazo-Duran, Maria
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (09) : 1347 - 1351
  • [36] Comparison of global indices and test duration between two visual field analyzers: Octopus 300 and Topcon SBP-3000
    Jose Javier Garcia-Medina
    Manuel Garcia-Medina
    Vicente Zanon-Moreno
    Carlos Garcia-Maturana
    Francisco Javier Cruz-Espinosa
    Maria Dolores Pinazo-Duran
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2012, 250 : 1347 - 1351
  • [37] Comparison between BNP and NT-proBNP diagnostic accuracy for early diagnosis of heart failure
    Emdin, M.
    Fontana, M.
    Giannoni, A.
    Gabutti, A.
    Mammini, C.
    Poletti, R.
    Prontera, C.
    Zyw, L.
    Clerico, A.
    Passino, C.
    EUROPEAN HEART JOURNAL, 2007, 28 : 306 - 306
  • [38] Comparison of diagnostic accuracy between EIA and LIA Helicobacter pylori antibody kits with the same antigen
    Kikuchi, S.
    Lin, Y.
    Wang, C.
    HELICOBACTER, 2017, 22
  • [39] Comparison of diagnostic accuracy between CellprepPlus® and ThinPrep® liquid-based preparations in effusion cytology
    Lee, Yong-Moon
    Hwang, Ji-Yong
    Son, Seung-Myoung
    Choi, Song-Yi
    Lee, Ho-Chang
    Kim, Eun-Joong
    Han, Hye-Suk
    An, Jin Young
    Han, Joung-Ho
    Lee, Ok-Jun
    DIAGNOSTIC CYTOPATHOLOGY, 2014, 42 (05) : 384 - 390
  • [40] Comparison of diagnostic accuracy between the chemiluminescence and electrochemical methods for nasal nitric oxide measurements in PCD
    Kouis, Panayiotis
    Chatziparasidis, Grigorios
    Boutopoulou, Barbara
    Omran, Heymut
    Kakkoura, Maria
    Papatheodorou, Stefania I.
    Kyriacou, Kyriacos
    Papadopoulos, Marios
    Grammeniatis, Vasilis
    Douros, Konstantinos
    Priftis, Kostas
    Yiallouros, Panayiotis K.
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52