An Open-Source Ultrasound Software for Diagnosis of Fistula Maturation

被引:7
|
作者
Belmont, Barry [1 ]
Park, Dae Woo [2 ]
Weitzel, William F. [3 ,4 ]
Shih, Albert J. [1 ,2 ]
机构
[1] Univ Michigan, Biomed Engn, Ann Arbor, MI 48109 USA
[2] Natl Canc Ctr, Innovat Med Engn & Technol, 323 Ilsan Ro, Goyang Si 10408, Gyeonggi Do, South Korea
[3] Vet Affairs Ann Arbor Hlth Syst, Ann Arbor, MI USA
[4] Internal Med, Ann Arbor, MI USA
关键词
autogenous arteriovenous fistulas; distensibility; flow gradient; DIAMETER; FAILURE; GRAFTS;
D O I
10.1097/MAT.0000000000000590
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Vascular access is essential for hemodialysis patients. The mature native arteriovenous fistula has been the preferred vascular access for hemodialysis, because it has greater longevity than synthetic grafts. However, once surgically created, fistulas often fail to develop (mature) into viable points of vascular access, requiring surgical or radiologic interventions before their use. Because maturation depends on vascular mechanics (e.g., distensibility and wall shear), we developed open-source ultrasound software to investigate these metrics clinically. We demonstrated in a single patient the ability of the software for consistent measurements from various locations within a cardiac cycle and between different cardiac cycles. We further assessed the ability of the software to identify changes in distensibility of a patient's fistula from 1 to 6 weeks postoperation. The routine frame rates of clinical machines demonstrated high fidelity tracking within cardiac cycles (coefficient of variation [CV] = 2.4% +/- 0.011) and between cardiac cycles (CV = 2.4% +/- 0.004). The distensibility of the patient's fistula from 1 to 6 weeks postoperation increased from 4% to 7% in the arterial inflow and from 3% to 4% in the postarterial anastomotic segment (PAAS). In contrast, the distensibility of the outflow vein decreased from 4% to 2%. These results corroborate that in addition to diameter changes, the mechanical properties of the vascular segments changed during fistula maturation. This demonstrates that our software-based approach may allow ultrasound-based mechanical measurements to become more accessible for wider clinical research.
引用
收藏
页码:70 / 76
页数:7
相关论文
共 50 条
  • [41] Open-source software entrepreneurial business modelling
    1600, Springer Science and Business Media, LLC (427):
  • [42] Free and Open-Source Software in Higher Education
    Oreski, Predrag
    Kermek, Dragutin
    Kirinic, Valentina
    CROATIAN JOURNAL OF EDUCATION-HRVATSKI CASOPIS ZA ODGOJ I OBRAZOVANJE, 2024, 26 (03): : 823 - 879
  • [43] Evaluation indicators for open-source software: a review
    Yuhang Zhao
    Ruigang Liang
    Xiang Chen
    Jing Zou
    Cybersecurity, 4
  • [44] Integrated open-source software for multiscale electrophysiology
    Nasiotis, Konstantinos
    Cousineau, Martin
    Tadel, Francois
    Peyrache, Adrien
    Leahy, Richard M.
    Pack, Christopher C.
    Baillet, Sylvain
    SCIENTIFIC DATA, 2019, 6 (1)
  • [45] Research brief - Open-source software development
    von Krogh, G
    MIT SLOAN MANAGEMENT REVIEW, 2003, 44 (03) : 14 - 18
  • [46] Open-source software: Freedom from ethics?
    Bernhard, Max
    Engineering and Technology, 2021, 16 (04):
  • [47] Sharing experiments using open-source software
    Nelson, Adam
    Menzies, Tim
    Gay, Gregory
    SOFTWARE-PRACTICE & EXPERIENCE, 2011, 41 (03): : 283 - 305
  • [48] Microgrid Planner: An Open-Source Software Platform
    Reich, Daniel
    Frye, Leah
    INFORMS JOURNAL ON COMPUTING, 2024,
  • [49] Evaluation indicators for open-source software: a review
    Zhao, Yuhang
    Liang, Ruigang
    Chen, Xiang
    Zou, Jing
    CYBERSECURITY, 2021, 4 (01)
  • [50] BRAVEHEART: Open-source software for automated electrocardiographic and
    Stabenau, Hans Friedrich
    Waks, Jonathan W.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2023, 242