An Open-Source Ultrasound Software for Diagnosis of Fistula Maturation

被引:7
|
作者
Belmont, Barry [1 ]
Park, Dae Woo [2 ]
Weitzel, William F. [3 ,4 ]
Shih, Albert J. [1 ,2 ]
机构
[1] Univ Michigan, Biomed Engn, Ann Arbor, MI 48109 USA
[2] Natl Canc Ctr, Innovat Med Engn & Technol, 323 Ilsan Ro, Goyang Si 10408, Gyeonggi Do, South Korea
[3] Vet Affairs Ann Arbor Hlth Syst, Ann Arbor, MI USA
[4] Internal Med, Ann Arbor, MI USA
关键词
autogenous arteriovenous fistulas; distensibility; flow gradient; DIAMETER; FAILURE; GRAFTS;
D O I
10.1097/MAT.0000000000000590
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Vascular access is essential for hemodialysis patients. The mature native arteriovenous fistula has been the preferred vascular access for hemodialysis, because it has greater longevity than synthetic grafts. However, once surgically created, fistulas often fail to develop (mature) into viable points of vascular access, requiring surgical or radiologic interventions before their use. Because maturation depends on vascular mechanics (e.g., distensibility and wall shear), we developed open-source ultrasound software to investigate these metrics clinically. We demonstrated in a single patient the ability of the software for consistent measurements from various locations within a cardiac cycle and between different cardiac cycles. We further assessed the ability of the software to identify changes in distensibility of a patient's fistula from 1 to 6 weeks postoperation. The routine frame rates of clinical machines demonstrated high fidelity tracking within cardiac cycles (coefficient of variation [CV] = 2.4% +/- 0.011) and between cardiac cycles (CV = 2.4% +/- 0.004). The distensibility of the patient's fistula from 1 to 6 weeks postoperation increased from 4% to 7% in the arterial inflow and from 3% to 4% in the postarterial anastomotic segment (PAAS). In contrast, the distensibility of the outflow vein decreased from 4% to 2%. These results corroborate that in addition to diameter changes, the mechanical properties of the vascular segments changed during fistula maturation. This demonstrates that our software-based approach may allow ultrasound-based mechanical measurements to become more accessible for wider clinical research.
引用
收藏
页码:70 / 76
页数:7
相关论文
共 50 条
  • [21] Unlocked: embedding open-source software
    Webb, W
    EDN, 2003, 48 (11) : 40 - +
  • [22] goGPS: open-source MATLAB software
    Antonio M. Herrera
    Hendy F. Suhandri
    Eugenio Realini
    Mirko Reguzzoni
    M. Clara de Lacy
    GPS Solutions, 2016, 20 : 595 - 603
  • [23] Open-source software: not quite endsville
    Stahl, MT
    DRUG DISCOVERY TODAY, 2005, 10 (03) : 219 - 222
  • [24] Greenstone: Open-source DL software
    Witten, IH
    Bainbridge, D
    Boddie, S
    COMMUNICATIONS OF THE ACM, 2001, 44 (05) : 47 - 47
  • [25] Who Chooses Open-Source Software?
    Lemley, Mark A.
    Shafir, Ziv
    UNIVERSITY OF CHICAGO LAW REVIEW, 2011, 78 (01): : 139 - 164
  • [26] Characterizing Commits in Open-Source Software
    Ferreira, Mivian M.
    Goncalves, Diego Santos
    Bigonha, Mariza A. S.
    Ferreira, Kecia A. M.
    PROCEEDINGS OF THE 21TH BRAZILIAN SYMPOSIUM ON SOFTWARE QUALITY, SBOS 2022, 2022,
  • [28] Open-source software for SEM metrology
    Mochi, Iacopo
    Vockenhuber, Michaela
    Allenet, Timothee
    Ekinci, Yasin
    PHOTOMASK TECHNOLOGY 2020, 2020, 11518
  • [29] Open-source software for geospatial analysis
    Isamar M. Cortés
    Nature Reviews Earth & Environment, 2023, 4 : 143 - 143
  • [30] Open-source software for geospatial analysis
    Cortes, Isamar M.