An Open-Source Ultrasound Software for Diagnosis of Fistula Maturation

被引:7
|
作者
Belmont, Barry [1 ]
Park, Dae Woo [2 ]
Weitzel, William F. [3 ,4 ]
Shih, Albert J. [1 ,2 ]
机构
[1] Univ Michigan, Biomed Engn, Ann Arbor, MI 48109 USA
[2] Natl Canc Ctr, Innovat Med Engn & Technol, 323 Ilsan Ro, Goyang Si 10408, Gyeonggi Do, South Korea
[3] Vet Affairs Ann Arbor Hlth Syst, Ann Arbor, MI USA
[4] Internal Med, Ann Arbor, MI USA
关键词
autogenous arteriovenous fistulas; distensibility; flow gradient; DIAMETER; FAILURE; GRAFTS;
D O I
10.1097/MAT.0000000000000590
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Vascular access is essential for hemodialysis patients. The mature native arteriovenous fistula has been the preferred vascular access for hemodialysis, because it has greater longevity than synthetic grafts. However, once surgically created, fistulas often fail to develop (mature) into viable points of vascular access, requiring surgical or radiologic interventions before their use. Because maturation depends on vascular mechanics (e.g., distensibility and wall shear), we developed open-source ultrasound software to investigate these metrics clinically. We demonstrated in a single patient the ability of the software for consistent measurements from various locations within a cardiac cycle and between different cardiac cycles. We further assessed the ability of the software to identify changes in distensibility of a patient's fistula from 1 to 6 weeks postoperation. The routine frame rates of clinical machines demonstrated high fidelity tracking within cardiac cycles (coefficient of variation [CV] = 2.4% +/- 0.011) and between cardiac cycles (CV = 2.4% +/- 0.004). The distensibility of the patient's fistula from 1 to 6 weeks postoperation increased from 4% to 7% in the arterial inflow and from 3% to 4% in the postarterial anastomotic segment (PAAS). In contrast, the distensibility of the outflow vein decreased from 4% to 2%. These results corroborate that in addition to diameter changes, the mechanical properties of the vascular segments changed during fistula maturation. This demonstrates that our software-based approach may allow ultrasound-based mechanical measurements to become more accessible for wider clinical research.
引用
收藏
页码:70 / 76
页数:7
相关论文
共 50 条
  • [1] A pilot study to measure vascular compliance changes during fistula maturation using open-source software
    Belmont, Barry
    Park, Dae Woo
    Shih, Albert
    Leavitt, Matthew
    Plattner, Brett
    Henke, Peter K.
    Weitzel, William F.
    JOURNAL OF VASCULAR ACCESS, 2019, 20 (01): : 41 - 45
  • [2] Open-source software - Introduction
    Sabbah, D
    Frye, D
    IBM SYSTEMS JOURNAL, 2005, 44 (02)
  • [3] Open-source bioinformatics software
    Vlagioiu, Constantin
    Vuta, Vlad
    Barbuceanu, Florica
    Predoi, Gabriel
    Tudor, Nicolae
    JOURNAL OF BIOTECHNOLOGY, 2017, 256 : S53 - S53
  • [4] Open-source software for repositories
    Vasilyeva, Natalya V.
    NAUCHNYE I TEKHNICHESKIE BIBLIOTEKI-SCIENTIFIC AND TECHNICAL LIBRARIES, 2023, (03): : 102 - 119
  • [5] OPEN-SOURCE SOFTWARE IN ROBOTICS
    Timoftei, Sanda
    Brad, Emilia
    Sarb, Anca
    Stan, Ovidiu
    ACTA TECHNICA NAPOCENSIS SERIES-APPLIED MATHEMATICS MECHANICS AND ENGINEERING, 2018, 61 (03): : 519 - 526
  • [6] Robust open-source software
    Neumann, PG
    COMMUNICATIONS OF THE ACM, 1999, 42 (02) : 128 - 128
  • [7] An Overview of Open-Source Software Licenses and the Value of Open-Source Software to Public Health Initiatives
    Hahn, Erin N.
    JOHNS HOPKINS APL TECHNICAL DIGEST, 2014, 32 (04): : 690 - 698
  • [8] Development of open-source software for free-hand 3D vascular ultrasound: Dialysis fistula application
    Weitzel, William F.
    Rajaram, Nirmala
    Zheng, Yihao
    Funes-Lora, Miguel Angel
    Hamilton, James
    Yessayan, Lenar
    Krishnamurthy, Venkataramu N.
    Henke, Peter
    Osborne, Nicholas
    Bishop, Brandie
    Shih, Albert J.
    Thelen, Brian J.
    JOURNAL OF VASCULAR ACCESS, 2023, 24 (04): : 722 - 728
  • [9] Reusing open-source software and practices: The impact of open-source on commercial vendors
    Brown, AW
    Booch, G
    SOFTWARE REUSE: METHODS, TECHNIQUES, AND TOOLS, PROCEEDINGS, 2002, 2319 : 123 - 136
  • [10] OPEN-SOURCE SIMULATION SOFTWARE "JAAMSIM"
    King, D. H.
    Harrison, Harvey S.
    2013 WINTER SIMULATION CONFERENCE (WSC), 2013, : 2163 - 2171