Optical Coherence Tomography Analysis of the Stenting of Saphenous Vein Graft (SOS) Xience V Study: Use of the Everolimus-Eluting Stent in Saphenous Vein Graft Lesions

被引:0
|
作者
Papayannis, Aristotelis C. [1 ,2 ]
Michael, Tesfaldet T. [1 ,2 ]
Yangirova, Dinara [2 ]
Abdel-karim, Abdul-rahman [1 ,2 ]
Kohlhaas, Julia [2 ]
Mahmood, Arif [1 ,2 ]
Addo, Tayo [2 ]
Haagen, Donald [1 ]
Makke, Lorenza [1 ]
Roesle, Michele [1 ]
Rangan, Bavana [1 ]
Banerjee, Subhash [1 ,2 ]
Brilakis, Emmanouil S. [1 ,2 ]
机构
[1] VA N Texas Healthcare Syst, Dallas, TX USA
[2] Univ Texas SW Med Ctr Dallas, Dallas, TX 75390 USA
来源
JOURNAL OF INVASIVE CARDIOLOGY | 2012年 / 24卷 / 08期
基金
美国国家卫生研究院;
关键词
saphenous vein grafts; drug-eluting stents; percutaneous coronary intervention; coronary artery bypass graft surgery; optical coherence tomography; BARE-METAL STENTS; CLINICAL FOLLOW-UP; NEOINTIMAL COVERAGE; INTRAVASCULAR ULTRASOUND; THROMBOSIS; IMPLANTATION; INTERVENTIONS; APPOSITION; DISEASE; 6-MONTH;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The Stenting of Saphenous Grafts-Xience V (SOS-Xience V) trial prospectively examined the frequency of angiographic in-stent restenosis in saphenous vein graft (SVG) lesions 12 months after implantation of a Xience V everolimus-eluting stent (EES; Abbott Vascular). Optical coherence tomography (OCT) during follow-up angiography was added to the protocol after OCT was approved for clinical use in the United States. Methods. Forty patients with 40 SVG lesions were enrolled in the study, of whom 27 underwent 12-month coronary angiography and 12 (only 1 of whom had in-stent restenosis) also had follow-up OCT evaluation. OCT strut-level analysis was performed to determine the percentage of strut coverage, malapposition, strut protrusion, neointimal thickness, and the existence of thrombus. Results. Mean patient age was 67 +/- 7 years, and 95% were men. A total of 2584 struts were evaluated by OCT. The percentages for uncovered, malapposed, and protruding struts were 4%, 9%, and 15%, respectively. The mean strut neointimal thickness was 0.094 +/- 0.094 mm. Of the 12 stents analyzed, 4 (33%) showed full neointimal coverage, 2 (17%) had all the struts embedded, 7 (58%) had at least 1 malapposed strut, and 10 (83%) had at least 1 protruding strut. The mean difference between the stent area and the lumen area was 0.36 +/- 1.6 mm(2). No thrombus was detected in the stented areas. Conclusions. Use of EES in SVGs is associated with high rates of stent strut coverage and high malapposition rates at 12 months post implantation.
引用
收藏
页码:390 / 394
页数:5
相关论文
共 50 条
  • [31] Complete fracture and restenosis of sirolimus-eluting stent in ostial saphenous vein graft
    Ohgo, Takeshi
    Otsuka, Yoritaka
    Furuno, Takashi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 128 (03) : E89 - E90
  • [32] Prevalence and Outcomes of Intermediate Saphenous Vein Graft Lesions: Findings from the Stenting of Saphenous Vein Grafts Randomized-Controlled Trial
    Abdel-karim, Abdul-rahman R.
    da Silva, Monica
    Lichtenwalter, Christopher
    de Lemos, James A.
    Obel, Owen
    Addo, Tayo
    Roesle, Michele
    Haagen, Donald
    Rangan, Bavana V.
    Makke, Lorenza
    Jeroudi, Omar M.
    Raghunathan, Deepa
    Saeed, Bilal
    Bissett, Joseph K.
    Sachdeva, Rajesh
    Voudris, Vassilios V.
    Karyofillis, Panagiotis
    Kar, Biswajit
    Rossen, James
    Fasseas, Panayotis
    Berger, Peter
    Banerjee, Subhash
    Brilakis, Emmanouil S.
    CIRCULATION, 2011, 124 (21)
  • [33] Prevalence and outcomes of intermediate saphenous vein graft lesions: Findings from the stenting of saphenous vein grafts randomized-controlled trial
    Abdel-karim, Abdul-rahman R.
    Da Silva, Monica
    Lichtenwalter, Christopher
    de Lemos, James A.
    Obel, Owen
    Addo, Tayo
    Roesle, Michele
    Haagen, Donald
    Rangan, Bavana V.
    Makke, Lorenza
    Jeroudi, Omar M.
    Raghunathan, Deepa
    Saeed, Bilal
    Bissett, Joseph K.
    Sachdeva, Rajesh
    Voudris, Vassilios V.
    Karyofillis, Panagiotis
    Kar, Biswajit
    Rossen, James
    Fasseas, Panayotis
    Berger, Peter
    Banerjee, Subhash
    Brilakis, Emmanouil S.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (03) : 2468 - 2473
  • [34] Clinical outcomes after sirolimus-eluting stent implantation for de Novo saphenous vein graft lesions
    Price, MJ
    Sawhney, N
    Kao, JA
    Madrid, A
    Schatz, RA
    Teirstein, PS
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 65 (02) : 208 - 211
  • [35] Contemporary Use of Embolic Protection Devices in Saphenous Vein Graft Interventions: Insights From the Stent of Saphenous Vein Grafts Trial
    Heuser, Richard R.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 77 (04) : 594 - 594
  • [36] Use of drug-eluting stents in saphenous vein aortocoronary bypass graft lesions: A critical appraisal
    Brilakis, Emmanouil S.
    Saeed, Bilal
    Banerjee, Subhash
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2008, 21 (02) : 151 - 157
  • [37] Efficacy Over Time With Drug-Eluting Stents in Saphenous Vein Graft Lesions
    Colleran, Roisin
    Kufner, Sebastian
    Mehilli, Julinda
    Rosenbeiger, Christian
    Schuepke, Stefanie
    Hoppmann, Petra
    Joner, Michael
    Mankerious, Nader
    Fusaro, Massimiliano
    Cassese, Salvatore
    Abdel-Wahab, Mohamed
    Neumann, Franz-Josef
    Richardt, Gert
    Ibrahim, Tareq
    Schunkert, Heribert
    Laugwitz, Karl-Ludwig
    Kastrati, Adnan
    Byrne, Robert A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (18) : 1973 - 1982
  • [38] Everolimus-eluting bioresorbable vascular scaffold implantation to treat saphenous vein graft disease, single-center initial experience
    Picard, Fabien
    Marquis-Gravel, Guillaume
    Avram, Robert
    Ly, Hung Q.
    Dorval, Jean-Francois
    Doucet, Serge
    de Hemptinne, Quentin
    L'allier, Philippe L.
    Tanguay, Jean-Francois
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2017, 30 (05) : 433 - 439
  • [39] Saphenous Vein Graft Aneurysm after Drug-Eluting Stent Implantation: Treatment by Covered Stent
    Papadopoulos, Kyriacos
    Avraamides, Panayiotis
    CASE REPORTS IN CARDIOLOGY, 2021, 2021
  • [40] PALMAZ-SCHATZ STENT IMPLANTATION IN THE TREATMENT OF SAPHENOUS-VEIN GRAFT LESIONS
    WONG, SC
    LEON, MB
    JOURNAL OF INVASIVE CARDIOLOGY, 1995, 7 : A23 - A29