Optical Coherence Tomography Analysis of the Stenting of Saphenous Vein Graft (SOS) Xience V Study: Use of the Everolimus-Eluting Stent in Saphenous Vein Graft Lesions

被引:0
|
作者
Papayannis, Aristotelis C. [1 ,2 ]
Michael, Tesfaldet T. [1 ,2 ]
Yangirova, Dinara [2 ]
Abdel-karim, Abdul-rahman [1 ,2 ]
Kohlhaas, Julia [2 ]
Mahmood, Arif [1 ,2 ]
Addo, Tayo [2 ]
Haagen, Donald [1 ]
Makke, Lorenza [1 ]
Roesle, Michele [1 ]
Rangan, Bavana [1 ]
Banerjee, Subhash [1 ,2 ]
Brilakis, Emmanouil S. [1 ,2 ]
机构
[1] VA N Texas Healthcare Syst, Dallas, TX USA
[2] Univ Texas SW Med Ctr Dallas, Dallas, TX 75390 USA
来源
JOURNAL OF INVASIVE CARDIOLOGY | 2012年 / 24卷 / 08期
基金
美国国家卫生研究院;
关键词
saphenous vein grafts; drug-eluting stents; percutaneous coronary intervention; coronary artery bypass graft surgery; optical coherence tomography; BARE-METAL STENTS; CLINICAL FOLLOW-UP; NEOINTIMAL COVERAGE; INTRAVASCULAR ULTRASOUND; THROMBOSIS; IMPLANTATION; INTERVENTIONS; APPOSITION; DISEASE; 6-MONTH;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The Stenting of Saphenous Grafts-Xience V (SOS-Xience V) trial prospectively examined the frequency of angiographic in-stent restenosis in saphenous vein graft (SVG) lesions 12 months after implantation of a Xience V everolimus-eluting stent (EES; Abbott Vascular). Optical coherence tomography (OCT) during follow-up angiography was added to the protocol after OCT was approved for clinical use in the United States. Methods. Forty patients with 40 SVG lesions were enrolled in the study, of whom 27 underwent 12-month coronary angiography and 12 (only 1 of whom had in-stent restenosis) also had follow-up OCT evaluation. OCT strut-level analysis was performed to determine the percentage of strut coverage, malapposition, strut protrusion, neointimal thickness, and the existence of thrombus. Results. Mean patient age was 67 +/- 7 years, and 95% were men. A total of 2584 struts were evaluated by OCT. The percentages for uncovered, malapposed, and protruding struts were 4%, 9%, and 15%, respectively. The mean strut neointimal thickness was 0.094 +/- 0.094 mm. Of the 12 stents analyzed, 4 (33%) showed full neointimal coverage, 2 (17%) had all the struts embedded, 7 (58%) had at least 1 malapposed strut, and 10 (83%) had at least 1 protruding strut. The mean difference between the stent area and the lumen area was 0.36 +/- 1.6 mm(2). No thrombus was detected in the stented areas. Conclusions. Use of EES in SVGs is associated with high rates of stent strut coverage and high malapposition rates at 12 months post implantation.
引用
收藏
页码:390 / 394
页数:5
相关论文
共 50 条
  • [21] Drug-eluting stents for saphenous vein graft lesions: useful or harmful?
    Jeger, Raban V.
    EUROINTERVENTION, 2010, 5 (06) : 647 - 648
  • [22] Treating saphenous vein graft lesions: Drug-eluting stents are not the answer!
    Hall, Allison B.
    Brilakis, Emmanouil S.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 93 (03) : E193 - E194
  • [23] Drug-Eluting Stents for Saphenous Vein Graft Lesions The Limits of Evidence
    Bittl, John A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (11) : 929 - 930
  • [24] Continued Benefit From Paclitaxel-Eluting Compared With Bare-Metal Stent Implantation in Saphenous Vein Graft Lesions During Long-Term Follow-Up of the SOS (Stenting of Saphenous Vein Grafts) Trial
    Brilakis, Emmanouil S.
    Lichtenwalter, Christopher
    Abdel-karim, Abdul-rahman R.
    de Lemos, James A.
    Obel, Owen
    Addo, Tayo
    Roesle, Michele
    Haagen, Donald
    Rangan, Bavana V.
    Saeed, Bilal
    Bissett, Joseph K.
    Sachdeva, Rajesh
    Voudris, Vassilios V.
    Karyofillis, Panagiotis
    Kar, Biswajit
    Rossen, James
    Fasseas, Panayotis
    Berger, Peter
    Banerjee, Subhash
    JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (02) : 176 - 182
  • [25] Excimer laser for a highly stenotic saphenous vein graft: evidence of debulking by optical coherence tomography
    Niccoli, Giampaolo
    Di Vito, Luca
    Montone, Rocco Antonio
    Porto, Italo
    Crea, Filippo
    EUROINTERVENTION, 2014, 9 (12) : 1484 - 1484
  • [26] Preliminary Experiences Using the MGuard Stent Platform in Saphenous Vein Graft Lesions
    Vaknin-Assa, Hana
    Assali, Abid
    Kornowski, Ran
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 74 (07) : 1055 - 1057
  • [27] INTRAVASCULAR ULTRASOUND MECHANISMS OF IN-STENT RESTENOSIS IN SAPHENOUS VEIN GRAFT LESIONS
    Wolny, Rafal
    Mintz, Gary
    Matsumura, Mitsuaki
    Ishida, Masaru
    Parviz, Yasir
    Fall, Khady
    Nazif, Tamim
    Parikh, Manish
    Rabbani, Leroy
    Collins, Michael
    Green, Philip
    Ali, Ziad
    Karmpaliotis, Dimitrios I.
    Brogno, David
    Kodali, Susheel K.
    Vahl, Torsten
    Parikh, Sahil
    Privitera, Lauren
    Leon, Martin B.
    Stone, Gregg
    Kirtane, Ajay
    Moses, Jeffrey
    Maehara, Akiko
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1251 - 1251
  • [28] Contemporary Use of Embolic Protection Devices in Saphenous Vein Graft Interventions: Insights From the Stenting of Saphenous Vein Grafts Trial
    Badhey, Neeraj
    Lichtenwalter, Christopher
    de Lemos, James A.
    Roesle, Michele
    Obel, Owen
    Addo, Tayo A.
    Haagen, Donald
    Abdel-Karim, Abdul-Rahman
    Saeed, Bilal
    Bissett, Joseph K.
    Sachdeva, Rajesh
    Voudris, Vassilios V.
    Karyofillis, Panagiotis
    Kar, Biswajit
    Rossen, James
    Fasseas, Panayotis
    Berger, Peter B.
    Banerjee, Subhash
    Brilakis, Emmanouil S.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 76 (02) : 263 - 269
  • [29] Impact of Drug-Eluting Stent Expansion on Saphenous Vein Graft Percutaneous Intervention
    Alemzadeh-Ansari, Mohammad Javad
    Firouzi, Ata
    Alimohammadi, Mousa
    Khalilipur, Ehsan
    Noohi, Feridoun
    Maleki, Majid
    Peighambari, Mohammad Mehdi
    Mohebbi, Bahram
    Zahedmehr, Ali
    Rashidinejad, Alireza
    Shakerian, Farshad
    Kiani, Reza
    Bakhshandeh, Hooman
    IRANIAN HEART JOURNAL, 2022, 23 (01):
  • [30] A completely fractured zotarolimus-eluting stent in an aortocoronary saphenous vein bypass graft
    Venero, Carmelo V.
    Aligeti, Venkata R.
    Wortham, Dale C.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (01) : 62 - 65