A Contact-Free Optical Device for the Detection of Pulmonary Congestion-A Pilot Study

被引:1
|
作者
Merdler, Ilan [1 ]
Hochstadt, Aviram [1 ]
Ghantous, Eihab [1 ]
Lupu, Lior [1 ]
Borohovitz, Ariel [1 ]
Zahler, David [1 ]
Taieb, Philippe [1 ]
Sadeh, Ben [1 ]
Zalevsky, Zeev [2 ,3 ]
Garcia-Monreal, Javier [2 ,4 ]
Shergei, Michael [2 ]
Shatsky, Maxim [2 ]
Beck, Yoav [2 ]
Polani, Sagi [2 ]
Arbel, Yaron [1 ,2 ]
机构
[1] Tel Aviv Univ, Tel Aviv Med Ctr, Dept Cardiol, 6 Weizmann St, IL-69978 Tel Aviv, Israel
[2] Formerly Contin Use Biometr Ltd, Donisi Hlth, IL-69978 Tel Aviv, Israel
[3] Bar Ilan Univ, Fac Engn, IL-52900 Ramat Gan, Israel
[4] Univ Valencia, Dept Opt, Valencia 46003, Spain
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 10期
关键词
contact-free; increased lung fluid content; congestion; heart failure; camera; remote monitoring; HEART-FAILURE; LUNG ULTRASOUND; PREVALENCE; MANAGEMENT;
D O I
10.3390/bios12100833
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: The cost of heart failure hospitalizations in the US alone is over USD 10 billion per year. Over 4 million Americans are hospitalized every year due to heart failure (HF), with a median length of stay of 4 days and an in-hospital mortality rate that exceeds 5%. Hospitalizations of patients with HF can be prevented by early detection of lung congestion. Our study assessed a new contact-free optical medical device used for the early detection of lung congestion. Methods: The Gili system is an FDA-cleared device used for measuring chest motion vibration data. Lung congestion in the study was assessed clinically and verified via two cardiologists. An algorithm was developed using machine learning techniques, and cross-validation of the findings was performed to estimate the accuracy of the algorithm. Results: A total of 227 patients were recruited (101 cases vs. 126 controls). The sensitivity and specificity for the device in our study were 0.91 (95% CI: 0.86-0.93) and 0.91 (95% CI: 0.87-0.94), respectively. In all instances, the observed estimates of PPVs and NPVs were at least 0.82 and 0.90, respectively. The accuracy of the algorithm was not affected by different covariates (including respiratory or valvular conditions). Conclusions: This study demonstrates the efficacy of a contact-free optical device for detecting lung congestion. Further validation of the study results across a larger and precise scale is warranted.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Toward Contact-Free Motion Sensing Technique in Low-Field MRI Using Beat Pilot Tone
    Chen, Suen
    Sun, Haoyu
    Anand, Suma
    Lustig, Michael
    Qiu, Yueqi
    Zhong, Sijie
    Chen, Hao
    Zhang, Zhiyong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74
  • [42] Mie scatter spectra-based device for instant, contact-free, and specific diagnosis of bacterial skin infection
    Robin E. Sweeney
    Elizabeth Budiman
    Jeong-Yeol Yoon
    Scientific Reports, 7
  • [43] Mie scatter spectra-based device for instant, contact-free, and specific diagnosis of bacterial skin infection
    Sweeney, Robin E.
    Budiman, Elizabeth
    Yoon, Jeong-Yeol
    SCIENTIFIC REPORTS, 2017, 7
  • [44] CONTACT-FREE OPTICAL CONTROL OF GROWTH AND TEMPERATURE SPEED DURING ORGANOMETALLIC GAS-PHASE EPITAXY
    LUKYANOV, AY
    NOVIKOV, MA
    SKOLOTOV, OV
    SHASHKIN, VI
    PISMA V ZHURNAL TEKHNICHESKOI FIZIKI, 1993, 19 (01): : 7 - 11
  • [45] Change-point detection using diffusion maps for sleep apnea monitoring with contact-free sensors
    Shirotori, Momo
    Sugitani, Yasuo
    PLOS ONE, 2024, 19 (06):
  • [46] A pilot study of a wearable apnoea detection device
    Rodriguez-Villegas, Esther
    Chen, Gwangwei
    Radcliffe, Jeremy
    Duncan, John
    BMJ OPEN, 2014, 4 (10):
  • [47] Microfluidic enrichment of bacteria coupled to contact-free lysis on a magnetic polymer surface for downstream molecular detection
    Burklund, Alison
    Petryk, James D.
    Hoopes, P. Jack
    Zhang, John X. J.
    BIOMICROFLUIDICS, 2020, 14 (03)
  • [48] Leveraging Optical Anisotropy of the Morpho Butterfly Wing for Quantitative, Stain-Free, and Contact-Free Assessment of Biological Tissue Microstructures
    Kirya, Paula
    Mestre-Farrera, Aida
    Yang, Jing
    Poulikakos, Lisa V.
    ADVANCED MATERIALS, 2025,
  • [49] A Low-Power Optical Receiver for Contact-free Programming and 3D Localization of Autonomous Microsystems
    Wheeler, Brad
    Ng, Andrew
    Kilberg, Brian
    Maksimovic, Filip
    Pister, Kristofer S. J.
    2019 IEEE 10TH ANNUAL UBIQUITOUS COMPUTING, ELECTRONICS & MOBILE COMMUNICATION CONFERENCE (UEMCON), 2019, : 371 - 376
  • [50] Theoretical study on the effect of temperature gradient on contact-free scanning for scanning ion conductance microscopy
    Wang, Zhiwu
    Zhuang, Jian
    Zhou, Lidong
    Li, Hongjuan
    Ning, Shaohui
    Liao, Xiaobo
    ULTRAMICROSCOPY, 2024, 267