A Contact-Free Optical Device for the Detection of Pulmonary Congestion-A Pilot Study

被引:1
|
作者
Merdler, Ilan [1 ]
Hochstadt, Aviram [1 ]
Ghantous, Eihab [1 ]
Lupu, Lior [1 ]
Borohovitz, Ariel [1 ]
Zahler, David [1 ]
Taieb, Philippe [1 ]
Sadeh, Ben [1 ]
Zalevsky, Zeev [2 ,3 ]
Garcia-Monreal, Javier [2 ,4 ]
Shergei, Michael [2 ]
Shatsky, Maxim [2 ]
Beck, Yoav [2 ]
Polani, Sagi [2 ]
Arbel, Yaron [1 ,2 ]
机构
[1] Tel Aviv Univ, Tel Aviv Med Ctr, Dept Cardiol, 6 Weizmann St, IL-69978 Tel Aviv, Israel
[2] Formerly Contin Use Biometr Ltd, Donisi Hlth, IL-69978 Tel Aviv, Israel
[3] Bar Ilan Univ, Fac Engn, IL-52900 Ramat Gan, Israel
[4] Univ Valencia, Dept Opt, Valencia 46003, Spain
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 10期
关键词
contact-free; increased lung fluid content; congestion; heart failure; camera; remote monitoring; HEART-FAILURE; LUNG ULTRASOUND; PREVALENCE; MANAGEMENT;
D O I
10.3390/bios12100833
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: The cost of heart failure hospitalizations in the US alone is over USD 10 billion per year. Over 4 million Americans are hospitalized every year due to heart failure (HF), with a median length of stay of 4 days and an in-hospital mortality rate that exceeds 5%. Hospitalizations of patients with HF can be prevented by early detection of lung congestion. Our study assessed a new contact-free optical medical device used for the early detection of lung congestion. Methods: The Gili system is an FDA-cleared device used for measuring chest motion vibration data. Lung congestion in the study was assessed clinically and verified via two cardiologists. An algorithm was developed using machine learning techniques, and cross-validation of the findings was performed to estimate the accuracy of the algorithm. Results: A total of 227 patients were recruited (101 cases vs. 126 controls). The sensitivity and specificity for the device in our study were 0.91 (95% CI: 0.86-0.93) and 0.91 (95% CI: 0.87-0.94), respectively. In all instances, the observed estimates of PPVs and NPVs were at least 0.82 and 0.90, respectively. The accuracy of the algorithm was not affected by different covariates (including respiratory or valvular conditions). Conclusions: This study demonstrates the efficacy of a contact-free optical device for detecting lung congestion. Further validation of the study results across a larger and precise scale is warranted.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Wi-Wheat: Contact-free Wheat Moisture Detection with Commodity WiFi
    Yang, Weidong
    Wang, Xuyu
    Song, Anxiao
    Mao, Shiwen
    2018 IEEE INTERNATIONAL CONFERENCE ON COMMUNICATIONS (ICC), 2018,
  • [32] Dynamic contact-free continuous-wave diffuse optical tomography system for the detection of vascular dynamics within the foot
    Khalil, M. A.
    Hoi, J.
    Kim, H. K.
    Hielscher, A. H.
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE X, 2013, 8578
  • [33] Suitability of Contact-Free Oxygen Optical Microsensors for Measuring Respiration and Photosynthesis in Green Algae
    Zhang, Xin
    Filser, Juliane
    FRONTIERS IN ENVIRONMENTAL SCIENCE, 2017, 5
  • [34] VALIDATION OF THE CONTACT-FREE SLEEP MONITORING DEVICE FOR DIAGNOSIS OF OBSTRUCTIVE SLEEP APNEA IN CHINESE ADULTS
    Dong, Xiaosong
    Zhi, Hui
    Chen, Jianan
    Han, Fang
    Zhao, Rui
    SLEEP, 2019, 42
  • [35] Design of an Armband Type Contact-Free Space Input Device for Human-Machine Interface
    Ryoo, Dongwan
    Park, Junseok
    IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS (ICCE 2011), 2011, : 841 - 842
  • [36] A Real-Time Contact-Free Atrial Fibrillation Detection System for Mobile Devices
    Tseng, Chih-Wei
    Wu, Bing-Fei
    Sun, Yu
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2025, 29 (01) : 17 - 29
  • [37] A NEW PHOTOELECTRIC DEVICE FOR CONTACT-FREE RECORDING OF DIAMETERS OF SHORT BLOOD-VESSEL SEGMENTS INVITRO
    TUTSCHKE, U
    BIOMEDIZINISCHE TECHNIK, 1988, 33 (7-8): : 166 - 172
  • [38] Machine Learning for Cognitive Load Classification - A Case Study on Contact-Free Approach
    Ahmed, Mobyen Uddin
    Begum, Shahina
    Gestlof, Rikard
    Rahman, Hamidur
    Sorman, Johannes
    ARTIFICIAL INTELLIGENCE APPLICATIONS AND INNOVATIONS, AIAI 2020, PT I, 2020, 583 : 31 - 42
  • [39] High-Throughput, Contact-Free Detection of Atrial Fibrillation From Video With Deep Learning
    Yan, Bryan P.
    Lai, William H. S.
    Chan, Christy K. Y.
    Au, Alex C. K.
    Freedman, Ben
    Poh, Yukkee C.
    Poh, Ming-Zher
    JAMA CARDIOLOGY, 2020, 5 (01) : 105 - 107
  • [40] FUNDAMENTAL STUDY OF MAGNETICALLY LEVITATED CONTACT-FREE MICRO-BEARING FOR MEMS APPLICATIONS
    Nakao, T.
    Han, H.
    Koshimoto, Y.
    INTERNATIONAL JOURNAL ON SMART SENSING AND INTELLIGENT SYSTEMS, 2010, 3 (03) : 536 - 549