Evaluation of Two Sinogram Interpolation Methods for Metal Artefacts Reduction in Computed Tomography

被引:0
|
作者
Osman, Noor Diyana [1 ]
Sobri, Nurul Fathin Mohamad [1 ]
Achuthan, Anusha [1 ]
Saidun, Halimatul Asma [1 ]
Aziz, Mohd Zahri Abdul [1 ]
Shuaib, Ibrahim Lutfi [1 ]
机构
[1] Univ Sains Malaysia, Cluster Oncol & Radiol Sci, Adv Med & Dent Inst, Kepala Batas, Malaysia
关键词
sinogram interpolation; metal artefact reduction; computed tomography; CT;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the presence of metal implant, it can induce streak artefacts appearance in computed tomography (CT) images that can degrade image quality and lead to misdiagnosis. A comparative study of two different sinogram interpolation methods for metal artefact reduction in CT images is presented. The metal part of the sinogram was determined and removed by thresholding technique. The missing part of the metal trace on the sinogram was interpolated by two interpolation methods which were cubic spline and Laplace interpolation. Both methods were applied to the selected CT images of different metal geometry and complexity. The effectiveness of both interpolation methods was compared. The results showed Laplace interpolation method produced the better results of gap filling as compared to cubic spline interpolation. But, it produces lower signal-to-noise ratio (SNR) values.
引用
收藏
页码:137 / 139
页数:3
相关论文
共 50 条
  • [31] Evaluation of Metal Artifact Reduction (MAR) Software On Computed Tomography (CT) Images
    Huang, V.
    Kohli, K.
    MEDICAL PHYSICS, 2015, 42 (06) : 3244 - 3244
  • [32] Analytic Computed Tomography Reconstruction in Sparse-Angular Sampling Using a Sinogram-Normalization Interpolation Method
    Guna Kim
    Chulkyu Park
    Dongyeon Lee
    Hyosung Cho
    Changwoo Seo
    Soyoung Park
    Kyuseok Kim
    Hyunwoo Lim
    Hunwoo Lee
    Seokyoon Kang
    Jeongeun Park
    Duhee Jeon
    Woosung Kim
    Younghwan Lim
    Journal of the Korean Physical Society, 2018, 73 : 361 - 367
  • [33] Analytic Computed Tomography Reconstruction in Sparse-Angular Sampling Using a Sinogram-Normalization Interpolation Method
    Kim, Guna
    Park, Chulkyu
    Lee, Dongyeon
    Cho, Hyosung
    Seo, Changwoo
    Park, Soyoung
    Kim, Kyuseok
    Lim, Hyunwoo
    Lee, Hunwoo
    Kang, Seokyoon
    Park, Jeongeun
    Jeon, Duhee
    Kim, Woosung
    Lim, Younghwan
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2018, 73 (03) : 361 - 367
  • [34] Evaluation of a prototype correction algorithm to reduce metal artefacts in flat detector computed tomography of scaphoid fixation screws
    Lukas Filli
    Magda Marcon
    Bernhard Scholz
    Maurizio Calcagni
    Tim Finkenstädt
    Gustav Andreisek
    Roman Guggenberger
    Skeletal Radiology, 2014, 43 : 1705 - 1712
  • [35] Dual layer computed tomography: Reduction of metal artefacts from posterior spinal fusion using virtual monoenergetic imaging
    Dangelmaier, Julia
    Schwaiger, Benedikt J.
    Gersing, Alexandra S.
    Kopp, Felix F.
    Sauter, Andreas
    Renz, Martin
    Riederer, Isabelle
    Braren, Rickmer
    Pfeiffer, Daniela
    Fingerle, Alexander
    Rummeny, Ernst J.
    Noel, Peter B.
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 105 : 195 - 203
  • [36] Evaluation of a prototype correction algorithm to reduce metal artefacts in flat detector computed tomography of scaphoid fixation screws
    Filli, Lukas
    Marcon, Magda
    Scholz, Bernhard
    Calcagni, Maurizio
    Finkenstaedt, Tim
    Andreisek, Gustav
    Guggenberger, Roman
    SKELETAL RADIOLOGY, 2014, 43 (12) : 1705 - 1712
  • [37] Artifact Reduction Based on Sinogram Interpolation for the 3D Reconstruction of Nanoparticles Using Electron Tomography
    Sentosun, Kadir
    Lobato, Ivan
    Bladt, Eva
    Zhang, Yang
    Palenstijn, Willem Jan
    Batenburg, Kees Joost
    Van Dyck, Dirk
    Bals, Sara
    PARTICLE & PARTICLE SYSTEMS CHARACTERIZATION, 2017, 34 (12)
  • [38] CAPABILITY EVALUATION OF A SINOGRAM ERROR-DETECTION AND CORRECTION METHOD IN COMPUTED-TOMOGRAPHY
    HUANG, SC
    YU, DC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) : 1106 - 1110
  • [39] Comparative Evaluation of the Artefacts Index of Dental Materials on Two-Dimensional Cone-beam Computed Tomography
    Yuan, Fusong
    Chen, Litong
    Wang, Xiaofei
    Wang, Yong
    Lyu, Peijun
    Sun, Yuchun
    SCIENTIFIC REPORTS, 2016, 6
  • [40] Comparative Evaluation of the Artefacts Index of Dental Materials on Two-Dimensional Cone-beam Computed Tomography
    Fusong Yuan
    Litong Chen
    Xiaofei Wang
    Yong Wang
    Peijun Lyu
    Yuchun Sun
    Scientific Reports, 6