Ultrasound tissue motion assessment using full correlation analysis

被引:0
|
作者
Taki, Hirofumi [1 ]
Sakamoto, Takuya [1 ]
Yamakawa, Makoto [1 ]
Shiina, Tsuyoshi [1 ]
Sato, Toru [1 ]
机构
[1] Kyoto Univ, Sakyo Ku, Kyoto 6068501, Japan
关键词
Tissue velocity estimation; ultrasound imaging; cross-correlation; full correlation analysis; BLOOD-FLOW; RADAR;
D O I
10.1109/ULTSYM.2012.0642
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Conventional ultrasound cross-correlation technique for tissue motion assessment searches the best match between successive B-mode frames. This strategy neglects the decrease of cross-correlation caused by the time difference between two measurement points utilized for the calculation of cross-correlation. The assumption causes the smaller estimated velocity than the true velocity. In this study, we employ full correlation analysis to compensate for the change of the location where the correlation coefficient is maximum. Simulation study shows that the difference between the true tissue velocity and the expectation of the tissue velocity estimated using the proposed method is 11.3% of that estimated using the conventional cross-correlation technique. These findings indicate the potential of the proposed method to improve the accuracy in tissue motion assessment, including blood flow velocity estimation.
引用
收藏
页码:2563 / 2566
页数:4
相关论文
共 50 条
  • [41] ANALYSIS OF LEFT VENTRICULAR WALL MOTION BY REFLECTED ULTRASOUND - APPLICATION TO ASSESSMENT OF MYOCARDIAL FUNCTION
    MCDONALD, IG
    FEIGENBAUM, H
    CHANG, S
    CIRCULATION, 1972, 46 (01) : 14 - +
  • [42] ANALYSIS OF LEFT VENTRICULAR WALL MOTION BY REFLECTED ULTRASOUND - APPLICATION TO ASSESSMENT OF MYOCARDIAL FUNCTION
    MCDONALD, IG
    FEIGENBAUM, H
    CHANG, S
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1971, 1 (03): : 322 - +
  • [43] Flexible Needle Steering in Moving Biological Tissue With Motion Compensation Using Ultrasound and Force Feedback
    Chevrie, Jason
    Shahriari, Navid
    Babel, Marie
    Krupa, Alexandre
    Misra, Sarthak
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2018, 3 (03): : 2338 - 2345
  • [44] Ultrasound tissue analysis and characterization
    Kaufhold, J
    Chan, R
    Karl, WC
    Castanon, DA
    BATTLEFIELD BIOMEDICAL TECHNOLOGIES, 1999, 3712 : 73 - 83
  • [45] Analysis of interorganisms relationship in a fish school using motion correlation techniques
    Inada, Y.
    Kawachi, K.
    Liu, H.
    COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY A-MOLECULAR & INTEGRATIVE PHYSIOLOGY, 2005, 141 (03): : S167 - S168
  • [46] Cloud motion analysis using multichannel correlation-relaxation labeling
    Evans, Adrian N.
    IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2006, 3 (03) : 392 - 396
  • [47] Cost assessment of filmless ultrasound using unit cost analysis
    Brandon W. Chan
    John R. Dorl
    M. Robert DeJong
    Ulrike M. Hamper
    Journal of Digital Imaging, 1998, 11 : 115 - 116
  • [48] Hepatic steatosis: Ultrasound assessment using attenuation imaging (ATI) with liver biopsy correlation
    Welman, Christopher J.
    Saunders, Jacqualine
    Zelesco, Marilyn
    Abbott, Steven
    Boardman, Glenn
    Ayonrinde, Oyekoya T.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2023, 67 (01) : 45 - 53
  • [49] NONINVASIVE ASSESSMENT OF THE CIRCLE OF WILLIS USING TRANSCRANIAL PULSED DOPPLER ULTRASOUND WITH ANGIOGRAPHIC CORRELATION
    CHAUDHURI, R
    PADAYACHEE, TS
    LEWIS, RR
    GOSLING, RG
    COX, TCS
    CLINICAL RADIOLOGY, 1992, 46 (03) : 193 - 197
  • [50] Cost assessment of filmless ultrasound using unit cost analysis
    Chan, BW
    Dorl, JR
    DeJong, MR
    Hamper, UM
    JOURNAL OF DIGITAL IMAGING, 1998, 11 (03) : 115 - 116