Ultrasound tissue motion assessment using full correlation analysis

被引:0
|
作者
Taki, Hirofumi [1 ]
Sakamoto, Takuya [1 ]
Yamakawa, Makoto [1 ]
Shiina, Tsuyoshi [1 ]
Sato, Toru [1 ]
机构
[1] Kyoto Univ, Sakyo Ku, Kyoto 6068501, Japan
关键词
Tissue velocity estimation; ultrasound imaging; cross-correlation; full correlation analysis; BLOOD-FLOW; RADAR;
D O I
10.1109/ULTSYM.2012.0642
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Conventional ultrasound cross-correlation technique for tissue motion assessment searches the best match between successive B-mode frames. This strategy neglects the decrease of cross-correlation caused by the time difference between two measurement points utilized for the calculation of cross-correlation. The assumption causes the smaller estimated velocity than the true velocity. In this study, we employ full correlation analysis to compensate for the change of the location where the correlation coefficient is maximum. Simulation study shows that the difference between the true tissue velocity and the expectation of the tissue velocity estimated using the proposed method is 11.3% of that estimated using the conventional cross-correlation technique. These findings indicate the potential of the proposed method to improve the accuracy in tissue motion assessment, including blood flow velocity estimation.
引用
收藏
页码:2563 / 2566
页数:4
相关论文
共 50 条
  • [31] The Assessment of the Possibility of Using Ethanol and Ultrasound to Design the Properties of Dried Carrot Tissue
    Dadan, Magdalena
    Nowacka, Malgorzata
    APPLIED SCIENCES-BASEL, 2021, 11 (02): : 1 - 19
  • [32] Tissue blood flow assessment of pulsed Doppler ultrasound using autoregressive modeling
    Bay Ö.F.
    Güler I.
    Journal of Medical Systems, 1999, 23 (1) : 77 - 81
  • [33] Assessment of neck tissue fibrosis using an ultrasound palpation system: A feasibility study
    Y. P. Zheng
    S. F. Leung
    A. F. T. Mak
    Medical and Biological Engineering and Computing, 2000, 38 : 497 - 502
  • [34] Changes in shoulder muscle activities and glenohumeral motion after rotator cuff repair: an assessment using ultrasound real-time tissue elastography
    Ishikawa, Hiroaki
    Muraki, Takayuki
    Morise, Shuhei
    Kurokawa, Daisuke
    Yamamoto, Nobuyuki
    Itoi, Eiji
    Izumi, Shin-Ichi
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2021, 30 (11) : 2577 - 2586
  • [35] Non-invasive Assessment of Soft-tissue Artefacts in Hip Joint Kinematics Using Motion Capture Data and Ultrasound Depth Measurements
    Rouhandeh, Azadeh
    Joslin, Chris
    Qu, Zhen
    Ono, Yuu
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 4342 - 4345
  • [36] Ultrasound Assessment of Anterior Neck Soft Tissue Thickness and Its Correlation with Difficult Laryngoscopy in Obese Patients
    Bhandari, Parshal
    Saleem, Jodat
    Aslam, Mudassar
    Saqib, Muhammad
    Nguyen Tien Huy
    ANESTHESIA AND ANALGESIA, 2024, 139 (06): : 32 - 33
  • [37] Ultrasound in the Assessment of Pulmonary Fibrosis in Connective Tissue Disorders: Correlation with High-Resolution Computed Tomography
    Tardella, Marika
    Gutierrez, Marwin
    Salaffi, Fausto
    Carotti, Marina
    Ariani, Alarico
    Bertolazzi, Chiara
    Filippucci, Emilio
    Grassi, Walter
    JOURNAL OF RHEUMATOLOGY, 2012, 39 (08) : 1641 - 1647
  • [38] Assessment of tissue Doppler imaging measurements of arterial wall motion using a tissue mimicking test rig
    Thrush, Abigail J.
    Brewin, Mark P.
    Birch, Malcolm J.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (03): : 446 - 453
  • [39] Ultrasound-Based Local Lung Motion Assessment Using Synthetic Lateral Phase
    Fung, Christopher M.
    Rubin, Jonathan M.
    Gao, Jing
    Hamilton, James D.
    JOURNAL OF CLINICAL ULTRASOUND, 2025,
  • [40] Ultrasound in the assessment of metatarsalgia: a surgical and histological correlation
    Oliver, TB
    Beggs, I