Semi-automated segmentation of pre-operative low grade gliomas in magnetic resonance imaging

被引:25
|
作者
Akkus, Zeynettin [1 ]
Sedlar, Jiri [1 ]
Coufalova, Lucie [1 ,2 ,3 ]
Korfiatis, Panagiotis [1 ]
Kline, Timothy L. [1 ]
Warner, Joshua D. [1 ]
Agrawal, Jay [1 ]
Erickson, Bradley J. [1 ]
机构
[1] Mayo Clin, Dept Radiol, 200 First St SW, Rochester, MN 55905 USA
[2] St Annes Univ Hosp Brno, Int Clin Res Ctr, Brno, Czech Republic
[3] Charles Univ Prague, Fac Med 1, Dept Neurosurg, Mil Univ Hosp, Prague, Czech Republic
基金
美国国家卫生研究院;
关键词
BRAIN-TUMOR SEGMENTATION; AUTOMATIC BRAIN; ALGORITHM; EVOLUTION; ATLAS; MODEL;
D O I
10.1186/s40644-015-0047-z
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Segmentation of pre-operative low-grade gliomas (LGGs) from magnetic resonance imaging is a crucial step for studying imaging biomarkers. However, segmentation of LGGs is particularly challenging because they rarely enhance after gadolinium administration. Like other gliomas, they have irregular tumor shape, heterogeneous composition, ill-defined tumor boundaries, and limited number of image types. To overcome these challenges we propose a semi-automated segmentation method that relies only on T2-weighted (T2W) and optionally post-contrast T1-weighted (T1W) images. Methods: First, the user draws a region-of-interest (ROI) that completely encloses the tumor and some normal tissue. Second, a normal brain atlas and post-contrast T1W images are registered to T2W images. Third, the posterior probability of each pixel/voxel belonging to normal and abnormal tissues is calculated based on information derived from the atlas and ROI. Finally, geodesic active contours use the probability map of the tumor to shrink the ROI until optimal tumor boundaries are found. This method was validated against the true segmentation (TS) of 30 LGG patients for both 2D (1 slice) and 3D. The TS was obtained from manual segmentations of three experts using the Simultaneous Truth and Performance Level Estimation (STAPLE) software. Dice and Jaccard indices and other descriptive statistics were computed for the proposed method, as well as the experts' segmentation versus the TS. We also tested the method with the BraTS datasets, which supply expert segmentations. Results and discussion: For 2D segmentation vs. TS, the mean Dice index was 0.90 +/- 0.06 (standard deviation), sensitivity was 0.92, and specificity was 0.99. For 3D segmentation vs. TS, the mean Dice index was 0.89 +/- 0.06, sensitivity was 0.91, and specificity was 0.99. The automated results are comparable with the experts' manual segmentation results. Conclusions: We present an accurate, robust, efficient, and reproducible segmentation method for pre-operative LGGs.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [31] Anaplastic transformation of low-grade gliomas (WHO II) on magnetic resonance imaging
    Bobek-Billewicz, Barbara
    Stasik-Pres, Gabriela
    Hebda, Anna
    Majchrzak, Krzysztof
    Kaspera, Wojciech
    Jurkowski, Marek
    FOLIA NEUROPATHOLOGICA, 2014, 52 (02) : 128 - 140
  • [32] Magnetic Resonance Arthrography, a valuable pre-operative imaging modality in femoro-acetabular impingement
    Nevien Ezzat El-Liethy
    Rania Zeitoun
    Heba Ahmed Kamal
    Ahmed Hazem Abd El-Azeem
    Egyptian Journal of Radiology and Nuclear Medicine, 50
  • [33] Impact of pre-operative breast magnetic resonance imaging upon surgical management of breast carcinoma
    Constantinidis, F.
    Christodoulidis, G.
    Spyridakis, M.
    Pappi, V.
    Dimas, D.
    Moustaka, A.
    Athanasiou, E.
    EJC SUPPLEMENTS, 2010, 8 (03): : 238 - 238
  • [34] Pediatric low-grade gliomas: Prognosis with proton magnetic resonance spectroscopic imaging
    Lazareff, JA
    Bockhorst, KHJ
    Curran, J
    Olmstead, C
    Alger, JR
    NEUROSURGERY, 1998, 43 (04) : 809 - 817
  • [35] Use of a semi-automated cardiac segmentation tool improves reproducibility and speed of segmentation of contaminated right heart magnetic resonance angiography
    Tandon, Animesh
    Byrne, Nicholas
    Forte, Maria de las Nieves Velasco
    Zhang, Song
    Dyer, Adrian K.
    Dillenbeck, Jeanne M.
    Greil, Gerald F.
    Hussain, Tarique
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (08): : 1273 - 1279
  • [36] Use of a semi-automated cardiac segmentation tool improves reproducibility and speed of segmentation of contaminated right heart magnetic resonance angiography
    Animesh Tandon
    Nicholas Byrne
    Maria de las Nieves Velasco Forte
    Song Zhang
    Adrian K. Dyer
    Jeanne M. Dillenbeck
    Gerald F. Greil
    Tarique Hussain
    The International Journal of Cardiovascular Imaging, 2016, 32 : 1273 - 1279
  • [37] A Semi-automated Approach to Improve the Efficiency of Medical Imaging Segmentation for Haptic Rendering
    Pat Banerjee
    Mengqi Hu
    Rahul Kannan
    Srinivasan Krishnaswamy
    Journal of Digital Imaging, 2017, 30 : 519 - 527
  • [38] High grade glioma segmentation in magnetic resonance imaging
    Vera, Miguel
    Huerfano, Yoleidy
    Javier Martinez, Luis
    Contreras, Yudith
    Salazar, Williams
    Isabel Vera, Maria
    Valbuena, Oscar
    Borrero, Maryury
    Hernandez, Carlos
    Barrera, Doris
    Valentin Molina, Angel
    Salazar, Juan
    Gelvez, Elkin
    Saenz, Frank
    Hoyos, Diego
    Arias, Yeny
    REVISTA LATINOAMERICANA DE HIPERTENSION, 2018, 13 (04): : 323 - 329
  • [39] A Semi-automated Approach to Improve the Efficiency of Medical Imaging Segmentation for Haptic Rendering
    Banerjee, Pat
    Hu, Mengqi
    Kannan, Rahul
    Krishnaswamy, Srinivasan
    JOURNAL OF DIGITAL IMAGING, 2017, 30 (04) : 519 - 527
  • [40] Diffusion-weighted magnetic resonance imaging for the pre-operative evaluation of epithelial ovarian cancer patients
    Feng, Zheng
    Fu, Yi
    Li, Ruimin
    Li, Haiming
    Lu, Jing
    Chen, Xiaojun
    Ju, Xingzhu
    Wu, Xiaohua
    Wen, Hao
    GYNECOLOGIC ONCOLOGY, 2023, 174 : 142 - 147