Use of a semi-automated cardiac segmentation tool improves reproducibility and speed of segmentation of contaminated right heart magnetic resonance angiography

被引:12
|
作者
Tandon, Animesh [1 ,2 ,3 ]
Byrne, Nicholas [5 ,6 ]
Forte, Maria de las Nieves Velasco [5 ]
Zhang, Song [4 ]
Dyer, Adrian K. [1 ,3 ]
Dillenbeck, Jeanne M. [2 ,3 ]
Greil, Gerald F. [1 ,2 ,3 ]
Hussain, Tarique [1 ,2 ,3 ]
机构
[1] Univ Texas Southwestern Med Ctr, Dept Pediat, Dallas, TX 75235 USA
[2] Univ Texas Southwestern Med Ctr, Dept Radiol, Dallas, TX 75235 USA
[3] Childrens Med Ctr Dallas, Pediat Cardiol, 1935 Med Dist Dr, Dallas, TX 75235 USA
[4] Univ Texas Southwestern Med Ctr, Dept Clin Sci, Dallas, TX USA
[5] Kings Coll London, Div Imaging Sci & Biomed Engn, London, England
[6] Guys & St Thomas NHS Fdn Trust, Med Phys, London, England
来源
关键词
Stereolithography; 3D printing; Magnetic resonance angiography; Cardiac segmentation; DISEASE; ADULTS;
D O I
10.1007/s10554-016-0906-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Three-dimensional printing has an increasing number of clinical applications in pediatric cardiology. Time required for dataset segmentation and conversion to stereolithography (STL) format remains a significant limitation. We investigated the impact of semi-automated cardiovascular-specific segmentation software on time and reproducibility of segmentation. Magnetic resonance angiograms (MRAs) of 19 patients undergoing intervention for right ventricular outflow lesions were segmented to demonstrate the right heart. STLs were created by two independent clinicians using semi-automated cardiovascular segmentation (SAS) and traditional manual segmentation (MS). Time was recorded and geometric STL disagreement was determined (0 % = no disagreement, 100 % = complete disagreement). MRA datasets were categorized as clean when only right heart structures were present in the MRA, or contaminated when left heart structures were also present and required removal. Eighteen (seven clean and 11 contaminated) cases were successfully segmented with both methods. Time to STL for clean datasets was faster with MS than SAS [median 209 s (IQR 192-252) vs. 296 s (272-317), p = 0.018] while contaminated datasets were faster with SAS [455 s (384-561) vs. 866 s (310-1429), p = 0.033]. Interobserver STL geometric disagreement was significantly lower using SAS than MS overall (0.70 +/- 1.15 % vs. 1.31 +/- 1.52 %, p = 0.030), and for the contaminated subset (0.81 +/- 1.08 % vs. 1.75 +/- 1.57 %, p = 0.036). Most geometric disagreement occurred at areas where left heart contamination was removed. Semi-automated segmentation was faster and more reproducible for contaminated datasets, while MS was faster but equally reproducible for clean datasets. Semi-automated segmentation methods are preferable for contaminated datasets and continued refinement of these tools should be supported.
引用
收藏
页码:1273 / 1279
页数:7
相关论文
共 50 条
  • [1] Use of a semi-automated cardiac segmentation tool improves reproducibility and speed of segmentation of contaminated right heart magnetic resonance angiography
    Animesh Tandon
    Nicholas Byrne
    Maria de las Nieves Velasco Forte
    Song Zhang
    Adrian K. Dyer
    Jeanne M. Dillenbeck
    Gerald F. Greil
    Tarique Hussain
    The International Journal of Cardiovascular Imaging, 2016, 32 : 1273 - 1279
  • [2] Visually interactive semi-automated 3D segmentation of cine cardiac magnetic resonance images
    Papademetris, X
    Rambo, J
    Dione, DP
    Sinusas, AJ
    Duncan, JS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 7A - 7A
  • [3] IMPLEMENTATION OF A SEMI-AUTOMATED SEGMENTATION TOOL FOR COLON SURGICAL PLANNING
    Lobato, C.
    Sanchez-Margallo, J. A.
    Sanchez-Margallo, F. M.
    BRITISH JOURNAL OF SURGERY, 2024, 111
  • [4] Semi-automated segmentation of the lateral periventricular regions using diffusion magnetic resonance imaging
    Isaacs, Albert M.
    Han, Rowland H.
    Smyser, Christopher D.
    Limbrick, David D., Jr.
    Shimony, Joshua S.
    METHODSX, 2020, 7
  • [5] Semi-automated carotid lumen segmentation in computed tomography angiography images
    Hamid Reza Hemmati
    Mahdi Alizadeh
    Alireza Kamali-Asl
    Shapour Shirani
    TheJournalofBiomedicalResearch, 2017, 31 (06) : 548 - 558
  • [6] IMPROVED SEMI-AUTOMATED SEGMENTATION OF CARDIAC CT AND MR IMAGES
    Li, Chao
    Jia, Xiao
    Sun, Ying
    2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 25 - 32
  • [7] Reproducibility of Radiogenomic Image Features: Comparison of Two Semi-Automated Segmentation Methods
    Lee, M.
    Woo, B.
    Kim, J.
    Jamshidi, N.
    Kuo, M.
    MEDICAL PHYSICS, 2015, 42 (06) : 3324 - 3324
  • [8] Clinical feasibility of a myocardial signal intensity threshold-based semi-automated cardiac magnetic resonance segmentation method
    Akos Varga-Szemes
    Giuseppe Muscogiuri
    U. Joseph Schoepf
    Julian L. Wichmann
    Pal Suranyi
    Carlo N. De Cecco
    Paola M. Cannaò
    Matthias Renker
    Stefanie Mangold
    Mary A. Fox
    Balazs Ruzsics
    European Radiology, 2016, 26 : 1503 - 1511
  • [9] Clinical feasibility of a myocardial signal intensity threshold-based semi-automated cardiac magnetic resonance segmentation method
    Varga-Szemes, Akos
    Muscogiuri, Giuseppe
    Schoepf, U. Joseph
    Wichmann, Julian L.
    Suranyi, Pal
    De Cecco, Carlo N.
    Cannao, Paola M.
    Renker, Matthias
    Mangold, Stefanie
    Fox, Mary A.
    Ruzsics, Balazs
    EUROPEAN RADIOLOGY, 2016, 26 (05) : 1503 - 1511
  • [10] CTScanTool, a semi-automated organ segmentation tool for radiotherapy treatment planning
    Liamsuwan, T.
    Tantisatirapong, S.
    Tangboonduangjit, P.
    INTERNATIONAL NUCLEAR SCIENCE AND TECHNOLOGY CONFERENCE, 2019, 1285