Use of a semi-automated cardiac segmentation tool improves reproducibility and speed of segmentation of contaminated right heart magnetic resonance angiography

被引:12
|
作者
Tandon, Animesh [1 ,2 ,3 ]
Byrne, Nicholas [5 ,6 ]
Forte, Maria de las Nieves Velasco [5 ]
Zhang, Song [4 ]
Dyer, Adrian K. [1 ,3 ]
Dillenbeck, Jeanne M. [2 ,3 ]
Greil, Gerald F. [1 ,2 ,3 ]
Hussain, Tarique [1 ,2 ,3 ]
机构
[1] Univ Texas Southwestern Med Ctr, Dept Pediat, Dallas, TX 75235 USA
[2] Univ Texas Southwestern Med Ctr, Dept Radiol, Dallas, TX 75235 USA
[3] Childrens Med Ctr Dallas, Pediat Cardiol, 1935 Med Dist Dr, Dallas, TX 75235 USA
[4] Univ Texas Southwestern Med Ctr, Dept Clin Sci, Dallas, TX USA
[5] Kings Coll London, Div Imaging Sci & Biomed Engn, London, England
[6] Guys & St Thomas NHS Fdn Trust, Med Phys, London, England
来源
关键词
Stereolithography; 3D printing; Magnetic resonance angiography; Cardiac segmentation; DISEASE; ADULTS;
D O I
10.1007/s10554-016-0906-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Three-dimensional printing has an increasing number of clinical applications in pediatric cardiology. Time required for dataset segmentation and conversion to stereolithography (STL) format remains a significant limitation. We investigated the impact of semi-automated cardiovascular-specific segmentation software on time and reproducibility of segmentation. Magnetic resonance angiograms (MRAs) of 19 patients undergoing intervention for right ventricular outflow lesions were segmented to demonstrate the right heart. STLs were created by two independent clinicians using semi-automated cardiovascular segmentation (SAS) and traditional manual segmentation (MS). Time was recorded and geometric STL disagreement was determined (0 % = no disagreement, 100 % = complete disagreement). MRA datasets were categorized as clean when only right heart structures were present in the MRA, or contaminated when left heart structures were also present and required removal. Eighteen (seven clean and 11 contaminated) cases were successfully segmented with both methods. Time to STL for clean datasets was faster with MS than SAS [median 209 s (IQR 192-252) vs. 296 s (272-317), p = 0.018] while contaminated datasets were faster with SAS [455 s (384-561) vs. 866 s (310-1429), p = 0.033]. Interobserver STL geometric disagreement was significantly lower using SAS than MS overall (0.70 +/- 1.15 % vs. 1.31 +/- 1.52 %, p = 0.030), and for the contaminated subset (0.81 +/- 1.08 % vs. 1.75 +/- 1.57 %, p = 0.036). Most geometric disagreement occurred at areas where left heart contamination was removed. Semi-automated segmentation was faster and more reproducible for contaminated datasets, while MS was faster but equally reproducible for clean datasets. Semi-automated segmentation methods are preferable for contaminated datasets and continued refinement of these tools should be supported.
引用
收藏
页码:1273 / 1279
页数:7
相关论文
共 50 条
  • [21] Semi-automated myocardial segmentation of bright blood multi-gradient echo images improves reproducibility of myocardial contours and T2* determination
    Pandji Triadyaksa
    Niek H. J. Prakken
    Jelle Overbosch
    Robin B. Peters
    J. Martijn van Swieten
    Matthijs Oudkerk
    Paul E. Sijens
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2017, 30 : 239 - 254
  • [22] Development and validation of SCAISS, a tool for semi-automated quantification of sacroilitis by magnetic resonance in spondyloarthritis
    Pedro Zarco
    Raquel Almodóvar
    Ángel Bueno
    Luis Miguel Molinero
    Rheumatology International, 2018, 38 : 1919 - 1926
  • [23] Development and validation of SCAISS, a tool for semi-automated quantification of sacroilitis by magnetic resonance in spondyloarthritis
    Zarco, Pedro
    Almodovar, Raquel
    Bueno, Angel
    Miguel Molinero, Luis
    RHEUMATOLOGY INTERNATIONAL, 2018, 38 (10) : 1919 - 1926
  • [24] The use of an active appearance model for automated prostate segmentation in magnetic resonance
    Korsager, Anne Sofie
    Stephansen, Ulrik Landberg
    Carl, Jesper
    Ostergaard, Lasse Riis
    ACTA ONCOLOGICA, 2013, 52 (07) : 1374 - 1377
  • [25] Semi-automated myocardial segmentation of bright blood multi-gradient echo images improves reproducibility of myocardial contours and T2*determination
    Triadyaksa, Pandji
    Prakken, Niek H. J.
    Overbosch, Jelle
    Peters, Robin B.
    van Swieten, J. Martijn
    Oudkerk, Matthijs
    Sijens, Paul E.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2017, 30 (03) : 239 - 254
  • [26] A Web-Based Tool for Semi-Automated Segmentation of Histopathological Images Using Nonlinear Color Classifiers
    Lopes, Marcelo Dornbusch
    Sobieranske, Antonio C.
    von Wangenheim, Aldo
    Comunello, Eros
    2016 IEEE 29TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS), 2016, : 247 - 252
  • [27] Combining generative modelling and semi-supervised domain adaptation for whole heart cardiovascular magnetic resonance angiography segmentation
    Muffoletto, Marica
    Xu, Hao
    Kunze, Karl P.
    Neji, Radhouene
    Botnar, Rene
    Prieto, Claudia
    Ruckert, Daniel
    Young, Alistair A.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2023, 25 (01)
  • [28] Combining generative modelling and semi-supervised domain adaptation for whole heart cardiovascular magnetic resonance angiography segmentation
    Marica Muffoletto
    Hao Xu
    Karl P. Kunze
    Radhouene Neji
    René Botnar
    Claudia Prieto
    Daniel Rückert
    Alistair A. Young
    Journal of Cardiovascular Magnetic Resonance, 25
  • [29] ACCURACY OF FULLY- AND SEMI-AUTOMATED ECHOCARDIOGRAPHIC ANALYSIS AGAINST CARDIAC MAGNETIC RESONANCE
    Hawkes, Will
    Knott, Kristopher
    Nikolou, Evgenia
    Akerman, Ashley
    Woodward, Gary
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 2316 - 2316
  • [30] Automated Heart Localization for the Segmentation of the Ventricular Cavities on Cine Magnetic Resonance Images
    Constantinides, C.
    Chenoune, Y.
    Mousseaux, E.
    Roullot, E.
    Frouin, F.
    COMPUTING IN CARDIOLOGY 2010, VOL 37, 2010, 37 : 911 - 914