Thermoelectric thick-film hydrogen gas sensor operating at room temperature

被引:73
|
作者
Shin, W [1 ]
Imai, K [1 ]
Izu, N [1 ]
Murayama, N [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Synergy Mat Res Ctr, Moriyama Ku, Nagoya, Aichi 4638560, Japan
来源
关键词
D O I
10.1143/JJAP.40.L1232
中图分类号
O59 [应用物理学];
学科分类号
摘要
A sensor of thick film NiO doped with alkali ions was fabricated and coated with Pt as the catalyst on half of its, surface. When this sensor was exposed to air mixed with hydrogen gas, the catalytic reaction heated up the Pt-coated surface, and then thermoelectric voltage appeared across the hot and cold region of the oxide film. At 22 degreesC, the sensor showed the built-up temperature difference and voltage signal of 0.12 degreesC and 0.087 mV, respectively, for the 100 ccm flow of 3% hydrogen/air mixed gas, with the full response time, T-90, of 55 s.
引用
收藏
页码:L1232 / L1234
页数:3
相关论文
共 50 条
  • [31] A novel semiconductor NO gas sensor operating at room temperature
    Zhang, WY
    Uchida, H
    Katsube, T
    Nakatsubo, T
    Nishioka, Y
    SENSORS AND ACTUATORS B-CHEMICAL, 1998, 49 (1-2) : 58 - 62
  • [32] The topology optimisation of thick-film electrochemical sensor
    Adamek, Martin
    Prasek, Jan
    Hladik, Jiri
    2007 30TH INTERNATIONAL SPRING SEMINAR ON ELECTRONICS TECHNOLOGY, 2007, : 139 - 142
  • [33] OSCILLATION PHENOMENON IN THICK-FILM CO SENSOR
    NITTA, M
    HARADOME, M
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1979, 26 (03) : 219 - 223
  • [34] Gas sensitivity of ZnO based thick film sensor to NH3 at room temperature
    Rao, GST
    Rao, DT
    SENSORS AND ACTUATORS B-CHEMICAL, 1999, 55 (2-3) : 166 - 169
  • [35] Gas sensitivity of ZnO based thick film sensor to NH3 at room temperature
    Rao, G.S. Trivikrama
    Tarakarama Rao, D.
    Sensors and Actuators, B: Chemical, 1999, 55 (02): : 166 - 169
  • [36] Room-temperature hydrogen gas sensor
    Raissi, F
    Farivar, R
    APPLIED PHYSICS LETTERS, 2005, 87 (16) : 1 - 3
  • [37] A THICK-FILM SENSOR FOR ATMOSPHERIC CORROSION TESTING
    FRAIGI, L
    GWIRC, SN
    LUPI, D
    SENSORS AND ACTUATORS B-CHEMICAL, 1994, 19 (1-3) : 558 - 561
  • [38] A THICK-FILM PYROELECTRIC PLZT CERAMIC SENSOR
    LEPPAVUORI, S
    LOZINSKI, AH
    UUSIMAKI, A
    SENSORS AND ACTUATORS A-PHYSICAL, 1995, 47 (1-3) : 391 - 394
  • [39] A THICK-FILM RESONANT SENSOR FOR HUMIDITY MEASUREMENTS
    MORTEN, B
    DECICCO, G
    PRUDENZIATI, M
    SENSORS AND ACTUATORS A-PHYSICAL, 1993, 37-8 : 337 - 342
  • [40] A novel thick-film ceramic humidity sensor
    Qu, WM
    Meyer, JU
    SENSORS AND ACTUATORS B-CHEMICAL, 1997, 40 (2-3) : 175 - 182