Thermoelectric thick-film hydrogen gas sensor operating at room temperature

被引:73
|
作者
Shin, W [1 ]
Imai, K [1 ]
Izu, N [1 ]
Murayama, N [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Synergy Mat Res Ctr, Moriyama Ku, Nagoya, Aichi 4638560, Japan
来源
关键词
D O I
10.1143/JJAP.40.L1232
中图分类号
O59 [应用物理学];
学科分类号
摘要
A sensor of thick film NiO doped with alkali ions was fabricated and coated with Pt as the catalyst on half of its, surface. When this sensor was exposed to air mixed with hydrogen gas, the catalytic reaction heated up the Pt-coated surface, and then thermoelectric voltage appeared across the hot and cold region of the oxide film. At 22 degreesC, the sensor showed the built-up temperature difference and voltage signal of 0.12 degreesC and 0.087 mV, respectively, for the 100 ccm flow of 3% hydrogen/air mixed gas, with the full response time, T-90, of 55 s.
引用
收藏
页码:L1232 / L1234
页数:3
相关论文
共 50 条
  • [21] THICK-FILM CO GAS SENSORS
    NITTA, M
    HARADOME, M
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1979, 26 (03) : 247 - 249
  • [22] Influence of ambient temperature on electronic conduction in thick-film gas sensors
    Giberti, A.
    Carotta, M. C.
    Guidi, V.
    Malagu, C.
    Martinelli, G.
    Milano, L.
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 137 (01) : 111 - 114
  • [23] AMPEROMETRIC HYDROGEN SENSOR USING PROTON CONDUCTOR (ANTIMONIC ACID) THICK-FILM
    MIURA, N
    HARADA, T
    SHIMIZU, Y
    YAMAZOE, N
    NIPPON KAGAKU KAISHI, 1991, (06) : 736 - 740
  • [24] THICK-FILM RESISTANCE TEMPERATURE DETECTORS
    EVANS, WD
    CONTROL AND INSTRUMENTATION, 1982, 14 (08): : 37 - &
  • [25] Thick-film resistive temperature sensors
    Dziedzic, A
    Golonka, LJ
    Kozlowski, J
    Licznerski, BW
    Nitsch, K
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1997, 8 (01) : 78 - 85
  • [26] Thick-film resistive temperature sensors
    Technical Univ of Wroclaw, Wroclaw, Poland
    Meas Sci Technol, 1 (78-85):
  • [27] A thick-film hydrogen sensor based on a ZnO:MoO3 formulation
    Dayan, NJ
    Sainkar, SR
    Karekar, RN
    Aiyer, RC
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (03) : 360 - 364
  • [28] Disposable creatinine sensor based on thick-film hydrogen peroxide electrode system
    Kim, EJ
    Haruyama, T
    Yanagida, Y
    Kobatake, E
    Aizawa, M
    ANALYTICA CHIMICA ACTA, 1999, 394 (2-3) : 225 - 231
  • [29] Novel semiconductor NO gas sensor operating at room temperature
    Saitama Univ, Urawa, Japan
    Sens Actuators, B Chem, 1-2 (58-62):
  • [30] A novel semiconductor NO gas sensor operating at room temperature
    Zhang, WY
    Uchida, H
    Katsube, T
    Nakatsubo, T
    Nishioka, Y
    TRANSDUCERS 97 - 1997 INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS AND ACTUATORS, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 1997, : 569 - 572