摘要
Patient-specific dosimetry in radiopharmaceutical therapy (RPT) is impeded by the lack of tools that are accurate and practical for the clinic. Our aims were to construct and test an integrated voxel-level pipeline that automates key components (organ segmentation, registration, dose-rate estimation, and curve fitting) of the RPT dosimetry process and then to use it to report patient-specific dosimetry in Lu-177-DOTATATE therapy. Methods: An integrated workflow that automates the entire dosimetry process, except tumor segmentation, was constructed. First, convolutional neural networks (CNNs) are used to automatically segment organs on the CT portion of one posttherapy SPECT/CT scan. Second, local contour intensity-based SPECT-SPECT alignment results in volume-of-interest propagation to other time points. Third, dose rate is estimated by explicit Monte Carlo (MC) radiation transport using the fast, Dose Planning Method code. Fourth, the optimal function for dose-rate fitting is automatically selected for each voxel. When reporting mean dose, we apply partial-volume correction, and uncertainty is estimated by an empiric approach of perturbing segmentations. Results: The workflow was used with 4-time-point Lu-177 SPECT/CT imaging data from 20 patients with 77 neuroendocrine tumors, segmented by a radiologist. CNN-defined kidneys resulted in high Dice values (0.91-0.94) and only small differences (2%-5%) in mean dose when compared with manual segmentation. Contour intensity-based registration led to visually enhanced alignment, and the voxel-level fitting had high R-2 values. Across patients, dosimetry results were highly variable; for example, the average of the mean absorbed dose (Gy/GBq) was 3.2 (range, 0.2-10.4) for lesions, 0.49 (range, 0.24-1.02) for left kidney, 0.54 (range, 0.31-1.07) for right kidney, and 0.51 (range, 0.27-1.04) for healthy liver. Patient results further demonstrated the high variability in the number of cycles needed to deliver hypothetical threshold absorbed doses of 23 Gy to kidney and 100 Gy to tumor. The uncertainty in mean dose, attributable to variability in segmentation, averaged 6% (range, 3%-17%) for organs and 10% (range, 3%-37%) for lesions. For a typical patient, the time for the entire process was about 25 min (similar to 2 min manual time) on a desktop computer, including time for CNN organ segmentation, coregistration, MC dosimetry, and voxel curve fitting. Conclusion: A pipeline integrating novel tools that are fast and automated provides the capacity for clinical translation of dosimetry-guided RPT.
引用
收藏
页码:1665 / 1672
页数:8
相关论文
共 50 条
  • [41] Long-Term Hematotoxicity After Peptide Receptor Radionuclide Therapy with 177Lu-Octreotate
    Sabet, Amir
    Ezziddin, Khaled
    Pape, Ulrich-Frank
    Ahmadzadehfar, Hojjat
    Mayer, Karin
    Poeppel, Thorsten
    Guhlke, Stefan
    Biersack, Hans-Juergen
    Ezziddin, Samer
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (11) : 1857 - 1861
  • [42] Long-term hematotoxicity after peptide receptor radionuclide therapy with 177Lu-octrotate
    Sabet, A.
    Ezziddin, K.
    Hense, J.
    Ahmadzadehfar, H.
    Nagarajah, J.
    Thorsten, P.
    Guhlke, S.
    Biersack, H.
    Ezziddin, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S233 - S233
  • [43] Long-term hematotoxicity after peptide receptor radionuclide therapy with 177Lu-octrotate
    Sabet, Amir
    Ezziddin, Khaled
    Hense, Joerg
    Ahmadzadehfar, Hojjat
    Nagarajah, James
    Poeppel, Thorsten
    Guhlke, Stefan
    Biersack, Hans Juergen
    Ezziddin, Samer
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [44] A Clinical Guide to Peptide Receptor Radionuclide Therapy with 177Lu-DOTATATE in Neuroendocrine Tumor Patients
    Becx, Morticia N.
    Minczeles, Noemie S.
    Brabander, Tessa
    de Herder, Wouter W.
    Nonnekens, Julie
    Hofland, Johannes
    CANCERS, 2022, 14 (23)
  • [45] Digital Reference Phantoms for Accuracy Assessment of Image-Based Dosimetry in 177Lu Peptide Receptor Radionuclide Therapy
    Brolin, G.
    Gustafsson, J.
    Ljungberg, M.
    Gleisner, K. Sjogreen
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S305 - S306
  • [46] Evaluation of Kidney Dose in Neuroendocrine Tumors Patients after Peptide Receptor Radionuclide Therapy using 177Lu-DOTATATE
    Hidayati, N. R.
    Poon, A.
    Willowson, K.
    Eslick, E.
    Ryu, H.
    Bailey, D. L.
    ATOM INDONESIA, 2019, 45 (03) : 147 - 152
  • [47] Bone marrow dosimetry in peptide receptor radionuclide therapy with [177Lu-DOTA0,Tyr3]octreotate
    Flavio Forrer
    Eric P. Krenning
    Peter P. Kooij
    Bert F. Bernard
    Mark Konijnenberg
    Willem H. Bakker
    Jaap J. M. Teunissen
    Marion de Jong
    Kirsten van Lom
    Wouter W. de Herder
    Dik J. Kwekkeboom
    European Journal of Nuclear Medicine and Molecular Imaging, 2009, 36
  • [48] Data collection procedures for bone marrow dosimetry in peptide receptor radionuclide therapy with 177Lu-DOTATATE on neuroendocrine tumors
    Frederiksen, M. H. B.
    Klausen, T. L.
    de Nijs, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S631 - S631
  • [49] Bone marrow dosimetry in peptide receptor radionuclide therapy with [177Lu-DOTA0,Tyr3]octreotate
    Forrer, Flavio
    Krenning, Eric P.
    Kooij, Peter P.
    Bernard, Bert F.
    Konijnenberg, Mark
    Bakker, Willem H.
    Teunissen, Jaap J. M.
    de Jong, Marion
    van Lom, Kirsten
    de Herder, Wouter W.
    Kwekkeboom, Dik J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (07) : 1138 - 1146
  • [50] Peptide Receptor Radionuclide Therapy using SSTR antagonists: biokinetics and dosimetry of Lu-177 DOTA-LM3
    Schuchardt, C.
    Wiessalla, S.
    Singh, A.
    Zhang, J.
    Kulkarni, H. R.
    Mueller, D.
    Baum, R. P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S90 - S90