A Pipeline for Automated Voxel Dosimetry: Application in Patients with Multi-SPECT/CT Imaging After 177Lu-Peptide Receptor Radionuclide Therapy

被引:18
|
作者
Dewaraja, Yuni K. [1 ]
Mirando, David M. [2 ]
Peterson, Avery B. [1 ,3 ]
Niedbala, Jeremy [1 ]
Millet, John D. [1 ]
Mikell, Justin K. [4 ]
Frey, Kirk A. [1 ]
Wong, Ka Kit [1 ]
Wilderman, Scott J. [1 ]
Nelson, Aaron S. [2 ]
机构
[1] Univ Michigan, Dept Radiol, Ann Arbor, MI 48104 USA
[2] MIM Software Inc, Cleveland, OH USA
[3] Wayne State Univ, Dept Radiat Oncol, Detroit, MI USA
[4] Univ Michigan, Radiat Oncol, Ann Arbor, MI USA
关键词
KIDNEY DOSIMETRY; IMAGES;
D O I
10.2967/jnumed.121.263738
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Patient-specific dosimetry in radiopharmaceutical therapy (RPT) is impeded by the lack of tools that are accurate and practical for the clinic. Our aims were to construct and test an integrated voxel-level pipeline that automates key components (organ segmentation, registration, dose-rate estimation, and curve fitting) of the RPT dosimetry process and then to use it to report patient-specific dosimetry in Lu-177-DOTATATE therapy. Methods: An integrated workflow that automates the entire dosimetry process, except tumor segmentation, was constructed. First, convolutional neural networks (CNNs) are used to automatically segment organs on the CT portion of one posttherapy SPECT/CT scan. Second, local contour intensity-based SPECT-SPECT alignment results in volume-of-interest propagation to other time points. Third, dose rate is estimated by explicit Monte Carlo (MC) radiation transport using the fast, Dose Planning Method code. Fourth, the optimal function for dose-rate fitting is automatically selected for each voxel. When reporting mean dose, we apply partial-volume correction, and uncertainty is estimated by an empiric approach of perturbing segmentations. Results: The workflow was used with 4-time-point Lu-177 SPECT/CT imaging data from 20 patients with 77 neuroendocrine tumors, segmented by a radiologist. CNN-defined kidneys resulted in high Dice values (0.91-0.94) and only small differences (2%-5%) in mean dose when compared with manual segmentation. Contour intensity-based registration led to visually enhanced alignment, and the voxel-level fitting had high R-2 values. Across patients, dosimetry results were highly variable; for example, the average of the mean absorbed dose (Gy/GBq) was 3.2 (range, 0.2-10.4) for lesions, 0.49 (range, 0.24-1.02) for left kidney, 0.54 (range, 0.31-1.07) for right kidney, and 0.51 (range, 0.27-1.04) for healthy liver. Patient results further demonstrated the high variability in the number of cycles needed to deliver hypothetical threshold absorbed doses of 23 Gy to kidney and 100 Gy to tumor. The uncertainty in mean dose, attributable to variability in segmentation, averaged 6% (range, 3%-17%) for organs and 10% (range, 3%-37%) for lesions. For a typical patient, the time for the entire process was about 25 min (similar to 2 min manual time) on a desktop computer, including time for CNN organ segmentation, coregistration, MC dosimetry, and voxel curve fitting. Conclusion: A pipeline integrating novel tools that are fast and automated provides the capacity for clinical translation of dosimetry-guided RPT.
引用
收藏
页码:1665 / 1672
页数:8
相关论文
共 50 条
  • [21] Serial Dosimetry in Peptide Receptor Radionuclide Therapy using Lu-177 DOTATATE or Lu-177 DOTATOC in the same Patient
    Schuchardt, C.
    Kulkarni, H.
    Baum, R. P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S139 - S139
  • [22] Single-Time-Point Dosimetry of 177Lu-PSMA-617 Radionuclide Therapy with SPECT/CT
    Burkerr, Brian J.
    RADIOLOGY-IMAGING CANCER, 2023, 5 (02):
  • [23] A dosimetry procedure for organs-at-risk in 177Lu peptide receptor radionuclide therapy of patients with neuroendocrine tumours
    Marin, Gwennaelle
    Vanderlinden, Bruno
    Karfis, Ioannis
    Guiot, Thomas
    Wimana, Zena
    Reynaert, Nick
    Vandenberghe, Stefaan
    Flamen, Patrick
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 56 : 41 - 49
  • [24] Towards a quality assurance for dosimetry in peptide receptor radionuclide therapy (PRRT) with 177Lu-DOTATATE
    Marin, G.
    Vanderlinden, B.
    Wimana, Z.
    Guiot, T.
    Karfis, I.
    Flamen, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S159 - S160
  • [25] DNA damage in blood lymphocytes in patients after 177Lu peptide receptor radionuclide therapy
    Uta Eberlein
    Carina Nowak
    Christina Bluemel
    Andreas Konrad Buck
    Rudolf Alexander Werner
    Harry Scherthan
    Michael Lassmann
    European Journal of Nuclear Medicine and Molecular Imaging, 2015, 42 : 1739 - 1749
  • [26] Radiopharmaceutical formulation and preliminary clinical dosimetry of [177Lu]Lu-DOTA-MGS5 for application in peptide receptor radionuclide therapy
    Zavvar, Taraneh Sadat
    Hoermann, Anton Amadeus
    Konijnenberg, Mark
    Kraihammer, Martin
    Mair, Christian
    Kronthaler, Ariane
    Joosten, Lieke
    Laverman, Peter
    Gruber, Leonhard
    di Santo, Gianpaolo
    Decristoforo, Clemens
    Virgolini, Irene
    von Guggenberg, Elisabeth
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2025, 52 (04) : 1321 - 1331
  • [27] DNA damage in blood lymphocytes in patients after 177Lu peptide receptor radionuclide therapy
    Eberlein, Uta
    Nowak, Carina
    Bluemel, Christina
    Buck, Andreas Konrad
    Werner, Rudolf Alexander
    Scherthan, Harry
    Lassmann, Michael
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (11) : 1739 - 1749
  • [28] Effect of peptide dose on radiation dosimetry for peptide receptor radionuclide therapy with 177Lu-DOTATOC: A pilot study
    Prasad, Vikas
    Prasad, Sonal
    Lehnert, Wencke
    Brenner, Winfried
    Kai, Huang
    Bronzel, Marcus
    Kluge, Andreas
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2021, 36 (04): : 412 - 421
  • [29] Evaluation of different infusion protocols and dosimetry assessment in patients undergoing peptide receptor radionuclide therapy with 177Lu-DOTATATE
    Varallo, A.
    Piscopo, L.
    Gaudieri, V.
    Grasso, S.
    Zampella, E.
    Nappi, C.
    Oliviero, C.
    Italiano, M.
    Volpe, F.
    Falzarano, M.
    Clemente, S.
    Cuocolo, A.
    Klain, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S649 - S649
  • [30] Dosimetry using Lu-177 DOTATATE, Lu-177 HA-DOTATATE and Lu-177 DOTATOC: Comparative Results in Patients Undergoing Peptide Receptor Radionuclide Therapy (PRRT)
    Schuchardt, C.
    Kulkarni, H. R.
    Wiessalla, S.
    Shahinfar, M.
    Shafaei, S.
    Kropf, S.
    Wester, H. J.
    Baum, R. P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S224 - S225