Evaluation of central corneal thickness after cataract surgery, penetrating keratoplasty and long-term soft contact lens wear

被引:5
|
作者
Sel, Saadettin [1 ,2 ]
Trau, Stefanie [3 ]
Knak, Matthias [3 ]
Kalinski, Thomas [4 ]
Kaiser, Delia [4 ]
Kruse, Friedrich E. [2 ]
Huchzermeyer, Cord [2 ]
Duncker, Gernot I. W. [5 ]
Paulsen, Friedrich [6 ]
Auffarth, Gerd U. [1 ]
Nass, Norbert [4 ]
机构
[1] Heidelberg Univ, Dept Ophthalmol, Heidelberg, Germany
[2] Univ Erlangen Nurnberg, Dept Ophthalmol, D-91054 Erlangen, Germany
[3] Univ Halle Wittenberg, Dept Ophthalmol, D-06108 Halle, Germany
[4] Otto Von Guericke Univ, Dept Pathol, Magdeburg, Germany
[5] Eye Laser Inst, Halle, Germany
[6] Univ Erlangen Nurnberg, Inst Anat, Dept 2, D-91054 Erlangen, Germany
来源
CONTACT LENS & ANTERIOR EYE | 2013年 / 36卷 / 05期
关键词
Central corneal thickness; Pachymetry; Intraocular lens; Phacoemulsification; Penetrating keratoplasty; Soft contact lens; ROTATING SCHEIMPFLUG CAMERA; ULTRASONIC PACHYMETRY; TOPOGRAPHY;
D O I
10.1016/j.clae.2013.03.002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to compare central corneal thickness (CCT) between corneas of normal healthy eyes (cNHE), corneas of eyes that had undergone cataract surgery by clear corneal phacoemulsification with implantation of an intracapsular intraocular lens (cIOL), corneal grafts after penetrating keratoplasty (gPK) and corneas of long-term soft contact lens wearers (cCL). Methods: The study design was a consecutive cross-sectional trial. CCT was measured using rotating Scheimpflug camera (Pentacam, software version 1.16r04) in 80 cNHE, 79 cIOL, 46 gPK and 78 cCL. Analysis of variance (one-way ANOVA) was performed to compare differences of mean values between these four groups. Pearson's or Spearman's correlation coefficient (r) was determined between CCT value and age, follow up time after penetrating keratoplasty (timePK) or contact lens wearing time (timeCL). Results: Means of CCf measurements were comparable between cNHE (mean CCT +/- standard deviation, 554 +/- 36 mu m), cIOL (551 +/- 40 mu m) and gPK (534 +/- 52 mu m) as determined by one-way ANOVA. Mean CCT values in cCL (537 +/- 37 mu m) were statistically significantly lower in comparison to cNHE (p = 0.026, 95% CI = 1.43-31.44). There was no linear correlation between age and CCT values of cNHE and cIOL (p = 0.841, r = -0.031 and p = 0.931, r = 0.011, respectively). No linear relationship was determined between CCf values of cCL and timeCL(p = 0.315, r = -0.125). CCT values of gPK did not correlate with timePK (p = 0.738, r = 0.054). Conclusions: The data reported here indicate that in the same statistical model among CCT values of cNHE, cIOL and gPK only long-term soft contact lenses (CL) wearer have significantly lower CCT measurements. (C) 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:238 / 242
页数:5
相关论文
共 50 条
  • [31] Changes in corneal thickness, corneal volume, and densitometry after long-term orthokeratology wear
    Zhang, Yue Evelyn
    Ouzzani, Mhamed
    Wright, Catherine
    Sorbara, Luigina
    CONTACT LENS & ANTERIOR EYE, 2023, 46 (01):
  • [32] Corneal epithelial thickness map in long-term soft contact lenses wearers
    1600, Lippincott Williams and Wilkins (91):
  • [33] Corneal Epithelial Thickness Map in Long-Term Soft Contact Lenses Wearers
    Hong, Jiaxu
    Qian, Tingting
    Yang, Yujing
    Jiang, Chunhui
    Liu, Zuguo
    Sun, Xinghuai
    Deng, Sophie X.
    Xu, Jianjiang
    OPTOMETRY AND VISION SCIENCE, 2014, 91 (12) : 1455 - 1461
  • [34] Long-term astigmatic changes after clear corneal cataract surgery
    MullerJensen, K
    Barlinn, B
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (03): : 354 - 357
  • [35] Long-Term Change in Corneal Astigmatism After Sutureless Cataract Surgery
    Hayashi, Ken
    Hirata, Akira
    Manabe, Shin-Ichi
    Hayashi, Hideyuki
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 151 (05) : 858 - 865
  • [36] Secondary Intraocular Lens Implantation After Simultaneous Penetrating Keratoplasty and Cataract Extraction for Coexisting Corneal and Lens Opacities
    Solaiman, Kamal A. M.
    El-Haig, Wael M.
    Bor'i, Ashraf
    Khalil, Ahmad S.
    Awad, Ahmed M. B.
    Al-Bialy, Hani A.
    Ibrahim, Basem M.
    CORNEA, 2019, 38 (04) : 397 - 402
  • [37] Central corneal thickness changes after phacoemulsification cataract surgery
    Salvi, Sachin M.
    Soong, Terrence K.
    Kumar, Balakrishna V.
    Hawksworth, Nicholas R.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (08): : 1426 - 1428
  • [38] Central Corneal Thickness Measurement After Cataract Surgery Reply
    Perone, Jean Marc
    Goetz, Christophe
    Lhuillier, Louis
    CORNEA, 2018, 37 (04) : E20 - E20
  • [39] Changes in central corneal thickness after congenital cataract surgery
    Faramarzi, Amir
    Javadi, Mohammad Ali
    Bonyadi, Mohammad Hossein Jabbarpoor
    Yaseri, Mehdi
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (12): : 2041 - 2047
  • [40] Long-term graft survival after penetrating keratoplasty
    Thompson, RW
    Price, MO
    Bowers, PJ
    Price, FW
    OPHTHALMOLOGY, 2003, 110 (07) : 1396 - 1402