Evaluation of central corneal thickness after cataract surgery, penetrating keratoplasty and long-term soft contact lens wear

被引:5
|
作者
Sel, Saadettin [1 ,2 ]
Trau, Stefanie [3 ]
Knak, Matthias [3 ]
Kalinski, Thomas [4 ]
Kaiser, Delia [4 ]
Kruse, Friedrich E. [2 ]
Huchzermeyer, Cord [2 ]
Duncker, Gernot I. W. [5 ]
Paulsen, Friedrich [6 ]
Auffarth, Gerd U. [1 ]
Nass, Norbert [4 ]
机构
[1] Heidelberg Univ, Dept Ophthalmol, Heidelberg, Germany
[2] Univ Erlangen Nurnberg, Dept Ophthalmol, D-91054 Erlangen, Germany
[3] Univ Halle Wittenberg, Dept Ophthalmol, D-06108 Halle, Germany
[4] Otto Von Guericke Univ, Dept Pathol, Magdeburg, Germany
[5] Eye Laser Inst, Halle, Germany
[6] Univ Erlangen Nurnberg, Inst Anat, Dept 2, D-91054 Erlangen, Germany
来源
CONTACT LENS & ANTERIOR EYE | 2013年 / 36卷 / 05期
关键词
Central corneal thickness; Pachymetry; Intraocular lens; Phacoemulsification; Penetrating keratoplasty; Soft contact lens; ROTATING SCHEIMPFLUG CAMERA; ULTRASONIC PACHYMETRY; TOPOGRAPHY;
D O I
10.1016/j.clae.2013.03.002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to compare central corneal thickness (CCT) between corneas of normal healthy eyes (cNHE), corneas of eyes that had undergone cataract surgery by clear corneal phacoemulsification with implantation of an intracapsular intraocular lens (cIOL), corneal grafts after penetrating keratoplasty (gPK) and corneas of long-term soft contact lens wearers (cCL). Methods: The study design was a consecutive cross-sectional trial. CCT was measured using rotating Scheimpflug camera (Pentacam, software version 1.16r04) in 80 cNHE, 79 cIOL, 46 gPK and 78 cCL. Analysis of variance (one-way ANOVA) was performed to compare differences of mean values between these four groups. Pearson's or Spearman's correlation coefficient (r) was determined between CCT value and age, follow up time after penetrating keratoplasty (timePK) or contact lens wearing time (timeCL). Results: Means of CCf measurements were comparable between cNHE (mean CCT +/- standard deviation, 554 +/- 36 mu m), cIOL (551 +/- 40 mu m) and gPK (534 +/- 52 mu m) as determined by one-way ANOVA. Mean CCT values in cCL (537 +/- 37 mu m) were statistically significantly lower in comparison to cNHE (p = 0.026, 95% CI = 1.43-31.44). There was no linear correlation between age and CCT values of cNHE and cIOL (p = 0.841, r = -0.031 and p = 0.931, r = 0.011, respectively). No linear relationship was determined between CCf values of cCL and timeCL(p = 0.315, r = -0.125). CCT values of gPK did not correlate with timePK (p = 0.738, r = 0.054). Conclusions: The data reported here indicate that in the same statistical model among CCT values of cNHE, cIOL and gPK only long-term soft contact lenses (CL) wearer have significantly lower CCT measurements. (C) 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:238 / 242
页数:5
相关论文
共 50 条
  • [21] Central corneal thickness after hypoxia in healthy humans and in soft contact lens wearers
    Katsoulis, K
    Goldblum, D
    Frueh, BE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U579 - U579
  • [22] FUNGAL KERATITIS ASSOCIATED WITH CONTACT-LENS WEAR AFTER PENETRATING KERATOPLASTY
    KREMER, I
    GOLDENFELD, M
    SHMUELI, D
    ANNALS OF OPHTHALMOLOGY, 1991, 23 (09): : 342 - 345
  • [23] The Long-Term Effects of Silicone Hydrogel Contact Lens Wear on Corneal Morphology
    Yildiz, Yelda
    Gurdal, Canan
    Sarac, Ozge
    Nacaroglu, Senay Asik
    Takmaz, Tamer
    Can, Izzet
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2012, 42 (02): : 91 - 96
  • [24] THE EFFECTS OF LONG-TERM, HARD CONTACT-LENS WEAR ON THE CORNEAL ENDOTHELIUM
    STEVENSON, RWW
    KIRKNESS, CM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 1292 - 1292
  • [25] DEEP CORNEAL STROMAL OPACITIES IN LONG-TERM CONTACT-LENS WEAR
    REMEIJER, L
    VANRIJ, G
    BEEKHUIS, WH
    POLAK, BCP
    VANNES, J
    OPHTHALMOLOGY, 1990, 97 (03) : 281 - 285
  • [26] THE LONG-TERM EFFECTS OF POLYMETHYLMETHACRYLATE CONTACT-LENS WEAR ON THE CORNEAL ENDOTHELIUM
    MACRAE, SM
    MATSUDA, M
    PHILLIPS, DS
    OPHTHALMOLOGY, 1994, 101 (02) : 365 - 370
  • [27] LONG-TERM PMMA CONTACT-LENS WEAR REDUCES CORNEAL FUNCTION
    MCMAHON, T
    POLSE, K
    MCNAMARA, N
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 1008 - 1008
  • [28] Long-term contact lens wear induces a corneal degeneration with microdot deposits in the corneal stroma
    Bohnke, M
    Masters, BR
    OPHTHALMOLOGY, 1997, 104 (11) : 1887 - 1896
  • [29] Increased Corneal Toricity after Long-Term Orthokeratology Lens Wear
    Chen, Zhi
    Zhou, Jiaqi
    Xue, Feng
    Zhou, Xingtao
    Qu, Xiaomei
    JOURNAL OF OPHTHALMOLOGY, 2018, 2018
  • [30] Long-term changes in intraocular lens position and corneal curvature after cataract surgery and their effect on refraction
    Klijn, Stijn
    Sicam, Victor Arni D. P.
    Reus, Nicolaas J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (01): : 35 - 43