Label-free detection of C-reactive protein using reflectometric interference spectroscopy-based sensing system

被引:37
|
作者
Choi, Hyung Woo [1 ]
Sakata, Yasuhiko [1 ]
Kurihara, Yoshikazu [1 ,2 ]
Ooya, Tooru [1 ]
Takeuchi, Toshifumi [1 ]
机构
[1] Kobe Univ, Grad Sch Engn, Nada Ku, Kobe, Hyogo 6578501, Japan
[2] KONICA MINOLTA OPTO Inc, Hino, Tokyo 1918511, Japan
关键词
Reflectometric interference spectroscopy (RIfS); C-reactive protein (CRP); Protein A; Carboxymethyl dextran (CMD); Label-free biosensing; SURFACE-PLASMON RESONANCE; THIN-FILM; IMMOBILIZATION; IMMUNOASSAY; DEXTRAN; DISEASE; DESIGN; ARRAY; ASSAY;
D O I
10.1016/j.aca.2012.03.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Reflectometric interference spectroscopy (RIfS) is a label-free, time-resolved technique, and suitable for detecting antibody-antigen interaction. This work describes a continuous flow biosensor for C-reactive protein (CRP), involving an effective immobilization method of a monoclonal antibody against CRP (anti-CRP) to achieve highly sensitive RIfS-based detection of CRP. The silicon nitride-coated silicon chip (SiN chip) for the RIfS sensing was first treated with trimethylsilylchloride (TMS), followed by UV-light irradiation to in situ generation of homogeneous silanols on the surface. Following amination by 3-aminopropyltriethoxysilane, carboxymethyldextran (CMD) was grafted, and subsequently, protein A was immobilized to create the oriented anti-CRP surface. The immobilization process of protein A and anti-CRP was monitored with the RIfS system by consecutive injections of an amine coupling reagent, protein A and anti-CRP, respectively, to confirm the progress of each step in real time. The sensitivity was enhanced when all of the processes were adopted, suggesting that the oriented immobilization of anti-CRP via protein A that was coupled with the grafted CMD on the aminated surface of TMS-treated SiN chip. The feasibility of the present sensing system was demonstrated on the detection of CRP, where the silicon-based inexpensive chips and the simple optical setup were employed. It can be applied to other target molecules in various fields of life science as a substitute of surface plasmon resonance-based expensive sensors. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:64 / 68
页数:5
相关论文
共 50 条
  • [41] Label-Free Specific Detection and Collection of C-Reactive Protein Using Zwitterionic Phosphorylcholine-Polymer-Protected Magnetic Nanoparticles
    Iwasaki, Sana
    Kawasaki, Hideya
    Iwasaki, Yasuhiko
    LANGMUIR, 2019, 35 (05) : 1749 - 1755
  • [42] Differential-mode HEMT-based biosensor for real-time and label-free detection of C-reactive protein
    Lee, Hee Ho
    Bae, Myunghan
    Jo, Sung-Hyun
    Shin, Jang-Kyoo
    Son, Dong Hyeok
    Won, Chul-Ho
    Lee, Jung-Hee
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 234 : 316 - 323
  • [43] A Simple Label-Free Aptamer-Based Electrochemical Biosensor for the Sensitive Detection of C-Reactive Proteins
    Gao, Huilin
    Bai, Yongchang
    He, Baixun
    Tan, Cherie S.
    BIOSENSORS-BASEL, 2022, 12 (12):
  • [44] Reflectometric interference spectroscopy-based immunosensing using immobilized antibody via His-tagged recombinant protein A
    Choi, Hyung Woo
    Sakata, Yasuhiko
    Ooya, Tooru
    Takeuchi, Toshifumi
    JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2015, 119 (02) : 195 - 199
  • [45] Demonstration of a Label-Free and Low-Cost Optical Cavity-Based Biosensor Using Streptavidin and C-Reactive Protein
    Rho, Donggee
    Kim, Seunghyun
    BIOSENSORS-BASEL, 2021, 11 (01):
  • [46] Label-free optical detection of C-reactive protein by nanoimprint lithography-based 2D-photonic crystal film
    Endo, Tatsuro
    Kajita, Hiroshi
    Kawaguchi, Yukio
    Kosaka, Terumasa
    Himi, Toshiyuki
    BIOTECHNOLOGY JOURNAL, 2016, 11 (06) : 831 - 837
  • [47] Oriented Antibody Covalent Immobilization for Label-Free Impedimetric Detection of C-Reactive Protein via Direct and Sandwich Immunoassays
    Adesina, Abiola
    Mashazi, Philani
    FRONTIERS IN CHEMISTRY, 2021, 9
  • [48] Real time and label-free detection of C-reactive protein in serum by long period grating in double cladding fiber
    Esposito, Flavio
    Sansone, Lucia
    Srivastava, Anubhav
    Baldini, Francesco
    Campopiano, Stefania
    Chiavaioli, Francesco
    Giordano, Michele
    Giannetti, Ambra
    Iadicicco, Agostino
    OPTICAL SENSORS 2021, 2021, 11772
  • [49] Interference terahertz label-free imaging for protein detection on a membrane
    Ogawa, Yuichi
    Hayashi, Shin'ichiro
    Oikawa, Masato
    Otani, Chiko
    Kawase, Kodo
    OPTICS EXPRESS, 2008, 16 (26): : 22083 - 22089
  • [50] Label-free protein detection using terahertz time-domain spectroscopy
    Han, Xiaohui
    Yan, Shihan
    Zang, Ziyi
    Wei, Dongshan
    Cui, Hong-Liang
    Du, Chunlei
    BIOMEDICAL OPTICS EXPRESS, 2018, 9 (03): : 994 - 1005