Label-free detection of C-reactive protein using reflectometric interference spectroscopy-based sensing system

被引:37
|
作者
Choi, Hyung Woo [1 ]
Sakata, Yasuhiko [1 ]
Kurihara, Yoshikazu [1 ,2 ]
Ooya, Tooru [1 ]
Takeuchi, Toshifumi [1 ]
机构
[1] Kobe Univ, Grad Sch Engn, Nada Ku, Kobe, Hyogo 6578501, Japan
[2] KONICA MINOLTA OPTO Inc, Hino, Tokyo 1918511, Japan
关键词
Reflectometric interference spectroscopy (RIfS); C-reactive protein (CRP); Protein A; Carboxymethyl dextran (CMD); Label-free biosensing; SURFACE-PLASMON RESONANCE; THIN-FILM; IMMOBILIZATION; IMMUNOASSAY; DEXTRAN; DISEASE; DESIGN; ARRAY; ASSAY;
D O I
10.1016/j.aca.2012.03.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Reflectometric interference spectroscopy (RIfS) is a label-free, time-resolved technique, and suitable for detecting antibody-antigen interaction. This work describes a continuous flow biosensor for C-reactive protein (CRP), involving an effective immobilization method of a monoclonal antibody against CRP (anti-CRP) to achieve highly sensitive RIfS-based detection of CRP. The silicon nitride-coated silicon chip (SiN chip) for the RIfS sensing was first treated with trimethylsilylchloride (TMS), followed by UV-light irradiation to in situ generation of homogeneous silanols on the surface. Following amination by 3-aminopropyltriethoxysilane, carboxymethyldextran (CMD) was grafted, and subsequently, protein A was immobilized to create the oriented anti-CRP surface. The immobilization process of protein A and anti-CRP was monitored with the RIfS system by consecutive injections of an amine coupling reagent, protein A and anti-CRP, respectively, to confirm the progress of each step in real time. The sensitivity was enhanced when all of the processes were adopted, suggesting that the oriented immobilization of anti-CRP via protein A that was coupled with the grafted CMD on the aminated surface of TMS-treated SiN chip. The feasibility of the present sensing system was demonstrated on the detection of CRP, where the silicon-based inexpensive chips and the simple optical setup were employed. It can be applied to other target molecules in various fields of life science as a substitute of surface plasmon resonance-based expensive sensors. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:64 / 68
页数:5
相关论文
共 50 条
  • [21] Label-free RNA aptamer-based capacitive biosensor for the detection of C-reactive protein
    Qureshi, Anjum
    Gurbuz, Yasar
    Kallempudi, Saravan
    Niazi, Javed H.
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2010, 12 (32) : 9176 - 9182
  • [22] Label-free parallel screening of combinatorial triazine libraries using reflectometric interference spectroscopy
    Birkert, O
    Tunnernann, R
    Jung, G
    Gauglitz, G
    ANALYTICAL CHEMISTRY, 2002, 74 (04) : 834 - 840
  • [23] Label-free detection of C-Reactive protein using bioresponsive hydrogel-based surface relief diffraction gratings
    Isabel Lucio, Maria
    Hernandez Montoto, Andy
    Fernandez, Estrella
    Alamri, Sabri
    Kunze, Tim
    Banuls, Maria-Jose
    Maquieira, Angel
    BIOSENSORS & BIOELECTRONICS, 2021, 193
  • [24] Label-free dynamic light scattering assay for C-reactive protein detection using magnetic nanoparticles
    Antonio, Maria
    Lima, Tania
    Vitorino, Rui
    Daniel-da-Silva, Ana L.
    ANALYTICA CHIMICA ACTA, 2022, 1222
  • [25] Molecular switching fluorescence based high sensitive detection of label-free C-reactive protein on biochip
    Islam, Md. Shahinul
    Yu, Hyunung
    Lee, Hee Gu
    Kang, Seong Ho
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (03): : 1028 - 1035
  • [26] A label-free fiber optic SPR biosensor for specific detection of C-reactive protein
    Wenjia Wang
    Zhigang Mai
    Yuzhi Chen
    Jiaqi Wang
    Liang Li
    Qingning Su
    Xuejin Li
    Xueming Hong
    Scientific Reports, 7
  • [27] An ultrasensitive label-free immunoassay for C-reactive protein detection in human serum based on electron transfer
    Zhang, Xi
    Hu, Rong
    Zhang, Kunlei
    Bai, Ruyan
    Li, Delei
    Yang, Yunhui
    ANALYTICAL METHODS, 2016, 8 (32) : 6202 - 6207
  • [28] A label-free fiber optic SPR biosensor for specific detection of C-reactive protein
    Wang, Wenjia
    Mai, Zhigang
    Chen, Yuzhi
    Wang, Jiaqi
    Li, Liang
    Su, Qingning
    Li, Xuejin
    Hong, Xueming
    SCIENTIFIC REPORTS, 2017, 7
  • [29] A New Device Based on Interferometric Optical Detection Method for Label-Free Screening of C-Reactive Protein
    Maigler, Maria V.
    Holgado, Miguel
    Fe Laguna, Maria
    Sanza, Francisco J.
    Santamaria, Beatriz
    Lavin, Alvaro
    Espinosa, Rocio L.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2019, 68 (09) : 3193 - 3199
  • [30] Reflectometric interference spectroscopy-based sensing for evaluating biodegradability of polymeric thin films
    Ooya, Tooru
    Sakata, Yasuhiko
    Choi, Hyung Woo
    Takeuchi, Toshifumi
    ACTA BIOMATERIALIA, 2016, 38 : 163 - 167