Label-free detection of C-reactive protein using reflectometric interference spectroscopy-based sensing system

被引:37
|
作者
Choi, Hyung Woo [1 ]
Sakata, Yasuhiko [1 ]
Kurihara, Yoshikazu [1 ,2 ]
Ooya, Tooru [1 ]
Takeuchi, Toshifumi [1 ]
机构
[1] Kobe Univ, Grad Sch Engn, Nada Ku, Kobe, Hyogo 6578501, Japan
[2] KONICA MINOLTA OPTO Inc, Hino, Tokyo 1918511, Japan
关键词
Reflectometric interference spectroscopy (RIfS); C-reactive protein (CRP); Protein A; Carboxymethyl dextran (CMD); Label-free biosensing; SURFACE-PLASMON RESONANCE; THIN-FILM; IMMOBILIZATION; IMMUNOASSAY; DEXTRAN; DISEASE; DESIGN; ARRAY; ASSAY;
D O I
10.1016/j.aca.2012.03.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Reflectometric interference spectroscopy (RIfS) is a label-free, time-resolved technique, and suitable for detecting antibody-antigen interaction. This work describes a continuous flow biosensor for C-reactive protein (CRP), involving an effective immobilization method of a monoclonal antibody against CRP (anti-CRP) to achieve highly sensitive RIfS-based detection of CRP. The silicon nitride-coated silicon chip (SiN chip) for the RIfS sensing was first treated with trimethylsilylchloride (TMS), followed by UV-light irradiation to in situ generation of homogeneous silanols on the surface. Following amination by 3-aminopropyltriethoxysilane, carboxymethyldextran (CMD) was grafted, and subsequently, protein A was immobilized to create the oriented anti-CRP surface. The immobilization process of protein A and anti-CRP was monitored with the RIfS system by consecutive injections of an amine coupling reagent, protein A and anti-CRP, respectively, to confirm the progress of each step in real time. The sensitivity was enhanced when all of the processes were adopted, suggesting that the oriented immobilization of anti-CRP via protein A that was coupled with the grafted CMD on the aminated surface of TMS-treated SiN chip. The feasibility of the present sensing system was demonstrated on the detection of CRP, where the silicon-based inexpensive chips and the simple optical setup were employed. It can be applied to other target molecules in various fields of life science as a substitute of surface plasmon resonance-based expensive sensors. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:64 / 68
页数:5
相关论文
共 50 条
  • [1] Label-free detection of glycoproteins using reflectometric interference spectroscopy-based sensing system with upright episcopic illumination
    Choi, Hyung Woo
    Takahashi, Hiroaki
    Ooya, Tooru
    Takeuchi, Toshifumi
    ANALYTICAL METHODS, 2011, 3 (06) : 1366 - 1370
  • [2] Two-layer reflectometric interference spectroscopy-based immunosensing for C-reactive protein
    Akiko Murata
    Tooru Ooya
    Toshifumi Takeuchi
    Microchimica Acta, 2015, 182 : 307 - 313
  • [3] Two-layer reflectometric interference spectroscopy-based immunosensing for C-reactive protein
    Murata, Akiko
    Ooya, Tooru
    Takeuchi, Toshifumi
    MICROCHIMICA ACTA, 2015, 182 (1-2) : 307 - 313
  • [4] Label-free detection of C-reactive protein using a carbon nanofiber based biosensor
    Gupta, Rakesh K.
    Periyakaruppan, Adaikkappan
    Meyyappan, M.
    Koehne, Jessica E.
    BIOSENSORS & BIOELECTRONICS, 2014, 59 : 112 - 119
  • [5] Label-free characterisation of oligonucleotide hybridisation using reflectometric interference spectroscopy
    Pröll, F
    Möhrle, B
    Kumpf, M
    Gauglitz, G
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (08) : 1889 - 1894
  • [6] Label-free characterisation of oligonucleotide hybridisation using reflectometric interference spectroscopy
    Florian Pröll
    Bernd Möhrle
    Michael Kumpf
    Günter Gauglitz
    Analytical and Bioanalytical Chemistry, 2005, 382 : 1889 - 1894
  • [7] Label-free detecting oligonucleotide hybridization melting temperature in real-time with a reflectometric interference spectroscopy-based nanosensor system
    Lu, Yao
    Sun, Dan
    Wang, Kaige
    Bai, Xiaohong
    Zhang, Chen
    Zhao, Wei
    Feng, Xiaoqiang
    Bai, Jintao
    OPTIK, 2019, 192
  • [8] Comparison of reflectometric interference spectroscopy with other instruments for label-free optical detection
    Hänel, C
    Gauglitz, G
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 372 (01) : 91 - 100
  • [9] Comparison of reflectometric interference spectroscopy with other instruments for label-free optical detection
    C. Hänel
    G. Gauglitz
    Analytical and Bioanalytical Chemistry, 2002, 372 : 91 - 100
  • [10] Chemiresistive CuO sensors for label-free C-reactive protein detection
    Bayansal, Fatih
    Cetinkara, Haci Ali
    JOURNAL OF ALLOYS AND COMPOUNDS, 2022, 926