Translation of Atherosclerotic Plaque Phase-Contrast CT Imaging from Synchrotron Radiation to a Conventional Lab-Based X-Ray Source

被引:26
|
作者
Saam, Tobias [1 ]
Herzen, Julia [2 ,7 ]
Hetterich, Holger [1 ]
Fill, Sandra [1 ]
Willner, Marian [2 ]
Stockmar, Marco [2 ]
Achterhold, Klaus [2 ]
Zanette, Irene [3 ]
Weitkamp, Timm [4 ]
Schueller, Ulrich [5 ]
Auweter, Sigrid [1 ]
Adam-Neumair, Silvia [6 ]
Nikolaou, Konstantin [1 ]
Reiser, Maximilian F. [1 ]
Pfeiffer, Franz [2 ]
Bamberg, Fabian [1 ]
机构
[1] Ludwig Maximilians Univ Hosp, Inst Clin Radiol, Munich, Germany
[2] Tech Univ Munich, Chair Biomed Phys, D-80290 Munich, Germany
[3] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[4] Synchrotron Soleil, Gif Sur Yvette, France
[5] Ludwig Maximilians Univ Hosp, Ctr Neuropathol, Munich, Germany
[6] Univ Munich, Inst Anat, Munich, Germany
[7] Helmholtz Zentrum Geesthacht, Inst Mat Res, Geesthacht, Germany
来源
PLOS ONE | 2013年 / 8卷 / 09期
基金
欧洲研究理事会;
关键词
TOMOGRAPHY; RISK; IVUS;
D O I
10.1371/journal.pone.0073513
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objectives: Phase-contrast imaging is a novel X-ray based technique that provides enhanced soft tissue contrast. The aim of this study was to evaluate the feasibility of visualizing human carotid arteries by grating-based phase-contrast tomography (PC-CT) at two different experimental set-ups: (i) applying synchrotron radiation and (ii) using a conventional X-ray tube. Materials and Methods: Five ex-vivo carotid artery specimens were examined with PC-CT either at the European Synchrotron Radiation Facility using a monochromatic X-ray beam (2 specimens; 23 keV; pixel size 5.4 mu m), or at a laboratory set-up on a conventional X-ray tube (3 specimens; 35-40 kVp; 70 mA; pixel size 100 mu m). Tomographic images were reconstructed and compared to histopathology. Two independent readers determined vessel dimensions and one reader determined signal-to-noise ratios (SNR) between PC-CT and absorption images. Results: In total, 51 sections were included in the analysis. Images from both set-ups provided sufficient contrast to differentiate individual vessel layers. All PCI-based measurements strongly predicted but significantly overestimated lumen, intima and vessel wall area for both the synchrotron and the laboratory-based measurements as compared with histology (all p<0.001 with slope >0.53 per mm(2), 95%-CI: 0.35 to 0.70). Although synchrotron-based images were characterized by higher SNRs than laboratory-based images; both PC-CT set-ups had superior SNRs compared to corresponding conventional absorption-based images (p<0.001). Inter-reader reproducibility was excellent (ICCs >0.98 and >0.84 for synchrotron and for laboratory-based measurements; respectively). Conclusion: Experimental PC-CT of carotid specimens is feasible with both synchrotron and conventional X-ray sources, producing high-resolution images suitable for vessel characterization and atherosclerosis research.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] X-ray phase-contrast imaging
    Endrizzi, Marco
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 878 : 88 - 98
  • [22] The Micro-structure of Shangjuxu Acupoint (ST37) by X-ray Phase-contrast CT Imaging based on Synchrotron Radiation
    Liu, Chenglin
    Wang, Fei
    Wang, Xiaohua
    Zhang, Dongming
    Zhang, Xinyi
    Liu, Fang
    Dang, Ruishan
    Xie, Honglan
    Xiao, Tiqiao
    2014 7TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2014), 2014, : 85 - 89
  • [23] Analyzer-based phase-contrast x-ray imaging of carotid plaque microstructure
    Appel, Alyssa A.
    Chou, Cheng-Ying
    Greisler, Howard P.
    Larson, Jeffery C.
    Vasireddi, Sunil
    Zhong, Zhong
    Anastasio, Mark A.
    Brey, Eric M.
    AMERICAN JOURNAL OF SURGERY, 2012, 204 (05): : 631 - 636
  • [24] Phase-contrast X-ray imaging based on interferometry
    Momose, A
    JOURNAL OF SYNCHROTRON RADIATION, 2002, 9 : 136 - 142
  • [25] Phase-contrast imaging and tomography at 60 keV using a conventional x-ray tube source
    Donath, Tilman
    Pfeiffer, Franz
    Bunk, Oliver
    Groot, Waldemar
    Bednarzik, Martin
    Gruenzweig, Christian
    Hempel, Eckhard
    Popescu, Stefan
    Hoheisel, Martin
    David, Christian
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (05):
  • [26] Grating-based X-ray phase-contrast tomography of atherosclerotic plaque at high photon energies
    Hetterich, Holger
    Fill, Sandra
    Herzen, Julia
    Willner, Marian
    Zanette, Irene
    Weitkamp, Timm
    Rack, Alexander
    Schueller, Ulrich
    Sadeghi, Mojtaba
    Brandi, Richard
    Adam-Neumair, Silvia
    Reiser, Maximilian
    Pfeiffer, Franz
    Bamberg, Fabian
    Saam, Tobias
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2013, 23 (03): : 194 - 203
  • [27] In-situ deformation imaging of articular cartilage using grating-based phase-contrast X-ray CT at a synchrotron light source
    Kawano S.
    Yagi T.
    Hoshino M.
    Matsumoto T.
    Journal of Biorheology, 2022, 36 (02): : 51 - 57
  • [28] Edge illumination X-ray phase-contrast imaging: nanoradian sensitivity at synchrotrons and translation to conventional sources
    Diemoz, P. C.
    Endrizzi, M.
    Hagen, C. K.
    Rau, C.
    Bravin, A.
    Speller, R. D.
    Robinson, I. K.
    Olivo, A.
    22ND INTERNATIONAL CONGRESS ON X-RAY OPTICS AND MICROANALYSIS, 2014, 499
  • [29] Optimal contrast for X-ray phase-contrast imaging
    College of Medical Instrument, University of Shanghai Science and Technology, Shanghai 200093, China
    不详
    Guangzi Xuebao, 2008, 6 (1217-1220):
  • [30] On analyzing of the contrast for X-ray phase-contrast imaging
    Liu, S.
    Zhang, X. L.
    Huang, Y.
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 1168 - 1171