Translation of Atherosclerotic Plaque Phase-Contrast CT Imaging from Synchrotron Radiation to a Conventional Lab-Based X-Ray Source

被引:26
|
作者
Saam, Tobias [1 ]
Herzen, Julia [2 ,7 ]
Hetterich, Holger [1 ]
Fill, Sandra [1 ]
Willner, Marian [2 ]
Stockmar, Marco [2 ]
Achterhold, Klaus [2 ]
Zanette, Irene [3 ]
Weitkamp, Timm [4 ]
Schueller, Ulrich [5 ]
Auweter, Sigrid [1 ]
Adam-Neumair, Silvia [6 ]
Nikolaou, Konstantin [1 ]
Reiser, Maximilian F. [1 ]
Pfeiffer, Franz [2 ]
Bamberg, Fabian [1 ]
机构
[1] Ludwig Maximilians Univ Hosp, Inst Clin Radiol, Munich, Germany
[2] Tech Univ Munich, Chair Biomed Phys, D-80290 Munich, Germany
[3] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[4] Synchrotron Soleil, Gif Sur Yvette, France
[5] Ludwig Maximilians Univ Hosp, Ctr Neuropathol, Munich, Germany
[6] Univ Munich, Inst Anat, Munich, Germany
[7] Helmholtz Zentrum Geesthacht, Inst Mat Res, Geesthacht, Germany
来源
PLOS ONE | 2013年 / 8卷 / 09期
基金
欧洲研究理事会;
关键词
TOMOGRAPHY; RISK; IVUS;
D O I
10.1371/journal.pone.0073513
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objectives: Phase-contrast imaging is a novel X-ray based technique that provides enhanced soft tissue contrast. The aim of this study was to evaluate the feasibility of visualizing human carotid arteries by grating-based phase-contrast tomography (PC-CT) at two different experimental set-ups: (i) applying synchrotron radiation and (ii) using a conventional X-ray tube. Materials and Methods: Five ex-vivo carotid artery specimens were examined with PC-CT either at the European Synchrotron Radiation Facility using a monochromatic X-ray beam (2 specimens; 23 keV; pixel size 5.4 mu m), or at a laboratory set-up on a conventional X-ray tube (3 specimens; 35-40 kVp; 70 mA; pixel size 100 mu m). Tomographic images were reconstructed and compared to histopathology. Two independent readers determined vessel dimensions and one reader determined signal-to-noise ratios (SNR) between PC-CT and absorption images. Results: In total, 51 sections were included in the analysis. Images from both set-ups provided sufficient contrast to differentiate individual vessel layers. All PCI-based measurements strongly predicted but significantly overestimated lumen, intima and vessel wall area for both the synchrotron and the laboratory-based measurements as compared with histology (all p<0.001 with slope >0.53 per mm(2), 95%-CI: 0.35 to 0.70). Although synchrotron-based images were characterized by higher SNRs than laboratory-based images; both PC-CT set-ups had superior SNRs compared to corresponding conventional absorption-based images (p<0.001). Inter-reader reproducibility was excellent (ICCs >0.98 and >0.84 for synchrotron and for laboratory-based measurements; respectively). Conclusion: Experimental PC-CT of carotid specimens is feasible with both synchrotron and conventional X-ray sources, producing high-resolution images suitable for vessel characterization and atherosclerosis research.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] X-ray phase-contrast CT imaging of the acupoints based on synchrotron radiation
    Chenglin, Liu
    Xiaohua, Wang
    Hua, Xu
    Fang, Liu
    Ruishan, Dang
    Dongming, Zhang
    Xinyi, Zhang
    Honglan, Xie
    Tiqiao, Xiao
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2014, 196 : 80 - 84
  • [2] Synchrotron radiation phase-contrast X-ray CT imaging of acupuncture points
    Dongming Zhang
    Xiaohui Yan
    Xinyi Zhang
    Chenglin Liu
    Ruishan Dang
    Tiqiao Xiao
    Peiping Zhu
    Analytical and Bioanalytical Chemistry, 2011, 401 : 803 - 808
  • [3] Synchrotron radiation phase-contrast X-ray CT imaging of acupuncture points
    Zhang, Dongming
    Yan, Xiaohui
    Zhang, Xinyi
    Liu, Chenglin
    Dang, Ruishan
    Xiao, Tiqiao
    Zhu, Peiping
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (03) : 803 - 808
  • [4] Atherosclerotic plaque imaging using phase-contrast X-ray computed tomography
    Shinohara, Masakazu
    Yamashita, Tomoya
    Tawa, Hideto
    Takeda, Masafurni
    Sasaki, Naoto
    Takeuchi, Akihisa
    Ohigashi, Takuji
    Shinohara, Kunio
    Hirata, Ken-ichi
    Kawashima, Seinosuke
    Yokoyama, Mitsuhiro
    Momose, Atsushi
    CIRCULATION, 2007, 116 (16) : 769 - 769
  • [5] Atherosclerotic plaque imaging using phase-contrast X-ray computed tomography
    Shinohara, Masakazu
    Yamashita, Tomoya
    Tawa, Hideto
    Takeda, Masafumi
    Sasaki, Naoto
    Takaya, Tomofumi
    Toh, Ryuji
    Takeuchi, Akihisa
    Ohigashi, Takuji
    Shinohara, Kunio
    Kawashima, Seinosuke
    Yokoyama, Mitsuhiro
    Hirata, Ken-Ichi
    Momose, Atsushi
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2008, 294 (02): : H1094 - H1100
  • [6] X-ray phase-contrast imaging at 100 keV on a conventional source
    Thuering, T.
    Abis, M.
    Wang, Z.
    David, C.
    Stampanoni, M.
    SCIENTIFIC REPORTS, 2014, 4
  • [7] X-ray phase-contrast imaging at 100 keV on a conventional source
    T. Thüring
    M. Abis
    Z. Wang
    C. David
    M. Stampanoni
    Scientific Reports, 4
  • [8] Phase-contrast X-ray imaging with synchrotron radiation for materials science applications
    Stevenson, AW
    Gureyev, TE
    Paganin, D
    Wilkins, SW
    Weitkamp, T
    Snigirev, A
    Rau, C
    Snigireva, I
    Youn, HS
    Dolbnya, IP
    Yun, W
    Lai, B
    Garrett, RF
    Cookson, DJ
    Hyodo, K
    Ando, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 199 : 427 - 435
  • [9] Phase-contrast imaging with synchrotron x-ray for mouse lung
    Chen, ZH
    Pan, L
    Li, G
    Xu, M
    Xu, B
    Zhao, TD
    Chen, WC
    Tang, JT
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2003, 27 : 83 - 85
  • [10] Phase-contrast imaging with microfocus x-ray source
    Chen, M
    Xiao, TQ
    Luo, YY
    Lu, LX
    Wei, X
    Du, GH
    Xu, HJ
    ACTA PHYSICA SINICA, 2004, 53 (09) : 2953 - 2957