EXPERIMENTAL STUDY OF THE PROCESSES OF GAS-STEAM PRESSURIZER INSURGE TRANSIENTS

被引:0
|
作者
Wang Bolong [1 ,2 ,3 ]
Li Weihua [1 ,2 ,3 ]
Jia Haijun [1 ,2 ,3 ]
Li Jun [1 ,2 ,3 ]
Hao Wentao [1 ,2 ,3 ]
机构
[1] Tsinghua Univ, Inst Nucl & New Energy Technol, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Collaborat Innovat Ctr Adv Nucl Energy Technol, Beijing, Peoples R China
[3] Tsinghua Univ, Key Lab Adv Reactor Engn & Safety, Minist Educ, Beijing, Peoples R China
关键词
Gas-steam pressurizer; Pressure response; Insurge transient; CONDENSATION;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Small reactors have received more and more attention for their high safety, reliability, low power density, and short construction period. And the gas-steam pressurizer is widely used in small reactors due to its characteristics of simple structure, saves the heating and spray equipment, and prevents the coolant from boiling. The gas-steam pressurizer is a pressure control equipment for the reactor coolant system, and its characteristic of transient response is an important factor that affect operation stability of nuclear reactor systems. An experimental system was established to study the effect of pressure response for an insurge transient and influence factors were analyzed quantitatively. Experimental investigation shows that for the gas-steam pressurizer, the increase of coolant loading capacity (insurge) can cause system pressure rising. And the change of system pressure has much consistency with the change of liquid level and gas space temperature. The liquid phase exists temperature fluctuations and overall shows a downward trend during the insurge transient. And there exists a temperature gradient from bottom to top in the pressurizer liquid phase region during the insurge transient. The change of water vapor quantity curve is the oscillating curve during the transient and water vapor quantity is in a decreasing trend overall during the insurge transient. What's more, the experiments also analyzed the pressure response and temperature response during the insurge transient.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Stability-and safety analysis of gas-steam furnace tubes
    Fang, DM
    Chai, G
    Li, DX
    Rao, BQ
    ENVIRONMENT EFFECTS ON FRACTURE AND DAMAGE, 2004, : 163 - 168
  • [32] Is There Any Future for the Combine Gas-steam Process in Power Plants? .
    Kunze, Bodo
    Elektrizitatswirtschaft, 1982, 81 (24): : 838 - 840
  • [33] Risk analysis of gas-steam combined cycle power plant
    Tang, Yong-Wei
    Zhongguo Dianli/Electric Power, 2002, 35 (04):
  • [34] Study on Load Characteristics of Multiple Operation Modes of Gas-steam Combined Cycle Cogeneration Unit
    Ge Z.
    Ma L.
    He J.
    Zhao S.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2020, 40 (08): : 2587 - 2596
  • [35] EXPERIENCE WITH GAS-STEAM COMBINED CYCLE TURBINES ON A NATURAL-GAS PIPELINE
    WRENN, KF
    HEARD, TC
    LANG, RP
    MECHANICAL ENGINEERING, 1977, 99 (07) : 92 - 92
  • [36] ENERGY AND COST EFFECTIVENESS ANALYSIS OF STEAM AND GAS-STEAM COMBINED HEAT AND POWER PLANTS
    Zaporowski, Boleslaw
    RYNEK ENERGII, 2008, (05): : 41 - 44
  • [37] STEAM CYCLE REGENERATION INFLUENCE ON COMBINED GAS-STEAM POWER PLANT PERFORMANCE.
    Cerri, G.
    Colage, A.
    Journal of Engineering for Gas Turbines and Power, 1985, 107 (03) : 574 - 581
  • [38] Decreasing the Weight-Size Parameters of Gas-Steam Turbine Plant by Increasing the Efficiency of Thermodynamic Processes in the Condenser
    Bortsov, O. S.
    Shevtsov, A. P.
    PROBLEMELE ENERGETICII REGIONALE, 2021, (04): : 43 - 58
  • [39] STEAM CYCLE REGENERATION INFLUENCE ON COMBINED GAS-STEAM POWER-PLANT PERFORMANCE
    CERRI, G
    COLAGE, A
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 1985, 107 (03): : 574 - 581
  • [40] EXPERIMENTAL INVESTIGATION AND MATHEMATICAL-MODELING OF THE PROCESSES IN A PRESSURIZER
    KORSHUNOV, AS
    MALTSEV, BK