EXPERIMENTAL STUDY OF THE PROCESSES OF GAS-STEAM PRESSURIZER INSURGE TRANSIENTS

被引:0
|
作者
Wang Bolong [1 ,2 ,3 ]
Li Weihua [1 ,2 ,3 ]
Jia Haijun [1 ,2 ,3 ]
Li Jun [1 ,2 ,3 ]
Hao Wentao [1 ,2 ,3 ]
机构
[1] Tsinghua Univ, Inst Nucl & New Energy Technol, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Collaborat Innovat Ctr Adv Nucl Energy Technol, Beijing, Peoples R China
[3] Tsinghua Univ, Key Lab Adv Reactor Engn & Safety, Minist Educ, Beijing, Peoples R China
关键词
Gas-steam pressurizer; Pressure response; Insurge transient; CONDENSATION;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Small reactors have received more and more attention for their high safety, reliability, low power density, and short construction period. And the gas-steam pressurizer is widely used in small reactors due to its characteristics of simple structure, saves the heating and spray equipment, and prevents the coolant from boiling. The gas-steam pressurizer is a pressure control equipment for the reactor coolant system, and its characteristic of transient response is an important factor that affect operation stability of nuclear reactor systems. An experimental system was established to study the effect of pressure response for an insurge transient and influence factors were analyzed quantitatively. Experimental investigation shows that for the gas-steam pressurizer, the increase of coolant loading capacity (insurge) can cause system pressure rising. And the change of system pressure has much consistency with the change of liquid level and gas space temperature. The liquid phase exists temperature fluctuations and overall shows a downward trend during the insurge transient. And there exists a temperature gradient from bottom to top in the pressurizer liquid phase region during the insurge transient. The change of water vapor quantity curve is the oscillating curve during the transient and water vapor quantity is in a decreasing trend overall during the insurge transient. What's more, the experiments also analyzed the pressure response and temperature response during the insurge transient.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] COMBINED GAS-STEAM CYCLE POWER-PLANTS
    BUCHET, E
    REVUE GENERALE DE THERMIQUE, 1981, 20 (233): : 391 - 404
  • [22] Energy and exergy analysis of steam cooled reheat gas-steam combined cycle
    Sanjay, Y.
    Singh, Onkar
    Prasad, B. N.
    APPLIED THERMAL ENGINEERING, 2007, 27 (17-18) : 2779 - 2790
  • [24] An Interior Trajectory Simulation of the Gas-steam Missile Ejection
    Liu, Yongquan
    Xi, Anmin
    JOURNAL OF COMPUTERS, 2013, 8 (05) : 1321 - 1326
  • [25] Steam turbine driving compressor for gas-steam combined cycle power plant
    Liu, Wancai
    Zhang, Hui
    IMECE2009, VOL 6, 2010, : 267 - 274
  • [26] Analysis of energy-conversion processes in gas-steam power-plants integrated with coal gasification
    Zaporowski, B
    APPLIED ENERGY, 2003, 74 (3-4) : 297 - 304
  • [27] LONG-DISTANCE HEAT SUPPLY BY GAS-STEAM CYCLE
    SELLEY, J
    ENERGIA ES ATOMTECHNIKA, 1977, 30 (11): : 505 - 509
  • [28] Technical and Economic Analysis of the Supercritical Combined Gas-Steam Cycle
    Jamroz, Marcin
    Piwowarski, Marian
    Ziemianski, Pawel
    Pawlak, Gabriel
    ENERGIES, 2021, 14 (11)
  • [29] CYCLIC GAS-STEAM STIMULATION OF HEAVY-OIL WELLS
    MELDAU, RF
    SHIPLEY, RG
    COATS, KH
    JOURNAL OF PETROLEUM TECHNOLOGY, 1981, 33 (10): : 1990 - 1998
  • [30] A new type of a gas-steam turbine cycle with increased efficiency
    Kolev, N
    Schaber, K
    Kolev, D
    APPLIED THERMAL ENGINEERING, 2001, 21 (04) : 391 - 405