EXPERIMENTAL STUDY OF THE PROCESSES OF GAS-STEAM PRESSURIZER INSURGE TRANSIENTS

被引:0
|
作者
Wang Bolong [1 ,2 ,3 ]
Li Weihua [1 ,2 ,3 ]
Jia Haijun [1 ,2 ,3 ]
Li Jun [1 ,2 ,3 ]
Hao Wentao [1 ,2 ,3 ]
机构
[1] Tsinghua Univ, Inst Nucl & New Energy Technol, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Collaborat Innovat Ctr Adv Nucl Energy Technol, Beijing, Peoples R China
[3] Tsinghua Univ, Key Lab Adv Reactor Engn & Safety, Minist Educ, Beijing, Peoples R China
关键词
Gas-steam pressurizer; Pressure response; Insurge transient; CONDENSATION;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Small reactors have received more and more attention for their high safety, reliability, low power density, and short construction period. And the gas-steam pressurizer is widely used in small reactors due to its characteristics of simple structure, saves the heating and spray equipment, and prevents the coolant from boiling. The gas-steam pressurizer is a pressure control equipment for the reactor coolant system, and its characteristic of transient response is an important factor that affect operation stability of nuclear reactor systems. An experimental system was established to study the effect of pressure response for an insurge transient and influence factors were analyzed quantitatively. Experimental investigation shows that for the gas-steam pressurizer, the increase of coolant loading capacity (insurge) can cause system pressure rising. And the change of system pressure has much consistency with the change of liquid level and gas space temperature. The liquid phase exists temperature fluctuations and overall shows a downward trend during the insurge transient. And there exists a temperature gradient from bottom to top in the pressurizer liquid phase region during the insurge transient. The change of water vapor quantity curve is the oscillating curve during the transient and water vapor quantity is in a decreasing trend overall during the insurge transient. What's more, the experiments also analyzed the pressure response and temperature response during the insurge transient.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] THE EFFECTS OF A NONCONDENSABLE GAS ON PRESSURIZER INSURGE TRANSIENTS
    LEONARD, MT
    GRIFFITH, P
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1984, 46 : 844 - 845
  • [2] Experiment Research on the Insurge Transient Behavior of Gas-steam Pressurizer under Various Pressure
    Wang Bolong
    Li Weihua
    Jia Haijun
    Li Jun
    Zhang Yajun
    ATW-INTERNATIONAL JOURNAL FOR NUCLEAR POWER, 2019, 64 (11-12): : 533 - 536
  • [3] NUMERICAL STUDY OF THE GAS-STEAM TRANSIENT BEHAVIOR IN THE INTEGRATED PRESSURIZER
    Wu Lei
    Jia Haijun
    Liu Yang
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 2, 2014,
  • [4] THE EFFECTS OF A NON-CONDENSABLE GAS ON PRESSURIZER INSURGE TRANSIENTS UNDER THE HIGH PRESSURE
    Wang Bolong
    Li Weihua
    Jia Haijun
    Li Jun
    PROCEEDINGS OF THE 26TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2018, VOL 6B, 2018,
  • [5] MIT PRESSURIZER PREDICTIONS DURING INSURGE TRANSIENTS USING TRAC-PF1 CODE
    HASSAN, YA
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1985, 50 (NOV): : 323 - 324
  • [6] Comparative thermodynamic and economic analysis of a conventional gas-steam power plant with a modified gas-steam power plant
    Bartnik, Ryszard
    Buryn, Zbigniew
    Hnydiuk-Stefan, Anna
    ENERGY CONVERSION AND MANAGEMENT, 2023, 293
  • [7] Efficiency of a combined gas-steam process
    Tuma, M
    Oman, J
    Sekavcnik, M
    ENERGY CONVERSION AND MANAGEMENT, 1999, 40 (11) : 1163 - 1175
  • [8] CENTRAL GAS-STEAM CONSORTIUM SOCOLIE IN LIEGE
    SCHADELI, R
    ELETTROTECNICA, 1969, 56 (08): : 459 - &
  • [9] COMBINED GAS-STEAM POWER-PLANTS
    GERGELY, B
    ENERGIA ES ATOMTECHNIKA, 1977, 30 (09): : 417 - 425
  • [10] INVESTIGATION OF A COMBINED GAS-STEAM SYSTEM WITH FLUE GAS RECIRCULATION
    Chmielniak, Tadeusz
    Monka, Pawel
    Pilarz, Pawel
    CHEMICAL AND PROCESS ENGINEERING-INZYNIERIA CHEMICZNA I PROCESOWA, 2016, 37 (02): : 305 - 316